CA GREEN CODE REQUIREMENTS r <br /> GENERAL NOTES m <br /> 1. PER CALGREEN SECTION 5.303.2, PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN <br /> CONSTRUCTION DOCUMENTS: TEMPORARY FACILITIES. UTILITIES & CONTROLS: IN TABLE 5.303.2.3. EXCEPTION: BUILDING THAT DEMONSTRATE 20% OVERALL WATER USE REDUCTION. IN THIS <br /> CASE, A CALCULATION DEMONSTRATING A 2% REDUCTION IN THE BUILDING 'WATER USE BASELINE," AS <br /> 1. BY EXECUTION OF THE CONSTRUCTION CONTRACT, THE CONTRACTOR REPRESENTS 1. PROVIDE BARRIERS, FENCES AND OTHER CONTROLS TO PREVENT PUBLIC ENTRY TO ESTABLISHED IN TABLE 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATIONS TO <br /> THAT HE OR SHE HAS (1) READ AND UNDERSTANDS THE REQUIREMENTS OF THE CONSTRUCTION AREAS, AND TO PROTECT CONSTRUCTION WORKERS AND THE PUBLIC THE BUILDING. Z <br /> CONSTRUCTION DOCUMENTS, (2) VISITED THE PROJECT-SITE, (3) BECOME FAMILIAR FROM HAZARDS OF CONSTRUCTION. o <br /> WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED, (4) MAXIMUM FIXTURE FLOW RATES: a <br /> CORRELATED PERSONAL OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT 2. PROVIDE PROTECTION OF CONSTRUCTION MATERIALS FROM LOSS, DAMAGE, FIRE OR FIXTURE TYPE MAXIMUM FLOW RATE Of <br /> THEFT, AND PROTECT EXISTING CONSTRUCTION FROM DAMAGE BY CONSTRUCTION 0 <br /> DOCUMENTS, AND (5) THAT HE OR SHE WILL COMPLY WITH ALL REQUIREMENTS OF LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM ® 60 PSI U)THE CONSTRUCTION DOCUMENTS. OPERATIONS. KITCHEN FAUCETS 1.8 GPM ® 60 PSI o <br /> 2. THE INTENT OF THE CONSTRUCTION DOCUMENTS IS TO INCLUDE ALL ITEMS 3. PROVIDE TEMPORARY FIRE-PREVENTION MEASURES AND PROCEDURES INCLUDING METERING FAUCETS 0.2 GALLONS/CYCLE <br /> NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE CONSTRUCTION FIRE-EXTINGUISHERS PER AHJ REQUIREMENTS. WATER CLOSETS 1.28 GALLONS/FLUSH <br /> WORK - AND TO PROVIDE (FURNISH AND INSTALL) ALL PRODUCTS, MATERIALS, URINALS (WALL MOUNTED) 0.125 GPC <br /> EQUIPMENT OR ACCESSORIES REQUIRED FOR PROPER OPERATION, IN ACCORDANCE 4. PROVIDE DUMPSTERS AND COLLECT WASTE DAILY. DISPOSE OF MATERIAL IN A <br /> WITH THEIR MANUFACTURER'S REQUIREMENTS. LAWFUL MANNER. PLACE DUMPSTER IN LOCATION APPROVED BY OWNER OR 2. PER CALGREEN SECTION 5.303.3.1, THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT <br /> LANDLORD, AS APPLICABLE. EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE w <br /> 3. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY - WHAT IS REQUIRED BY ONEGENERAL PRODUCT REQUIREMENTS: CRITERIA OF THE US EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE o <br /> SHALL BE AS BINDING AS IF REQUIRED BY ALL. WHILE PREPARED WITH DUE CARE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO <br /> AND DILIGENCE, PERFECTION IS NOT POSSIBLE. DESIGN AND CONSTRUCTION AREREDUCES FLUSHES AND ONE FULL FLUSH. <br /> COMPLEX - EVERY POSSIBLE CONDITION OR CONTINGENCY CANNOT BE ANTICIPATED 1. STORE PRODUCTS PER MANUFACTURER'S INSTRUCTIONS, PROTECTED FROM DAMAGE <br /> OR FULLY INDICATED WITHIN THE DOCUMENTS. OR ABUSE, AND WITH VENTILATION TO AVOID CONDENSATION. 3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE Of <br /> DEPOSITING STORAGE AND COLLECTION OF NONHAZARDOUS MATERIALS FOR RECYCLING. PER SECTION <br /> 2. APPLICATION OF A MATERIAL OR EQUIPMENT ITEM TO WORK INSTALLED BY OTHERS 5.410.1.1 ANY ADDITION OR ALTERATION RESULTING IN LESS THAN A 30% INCREASE IN THE TENANT SPACE z w rn <br /> 4. CAREFULLY STUDY AND COMPARE THE VARIOUS DRAWINGS (INCLUDING BUT NOT CONSTITUTES ACCEPTANCE OF THAT WORK AND ASSUMPTION OF RESPONSIBILITY FOR FLOOR AREA IS EXEMPT FROM THIS REQUIREMENT. =Q a r rn 0)m w U <br /> LIMITED TO ARCHITECTURAL, STRUCTURAL, MECHANICAL OR ELECTRICAL) AND OTHER SATISFACTORY INSTALLATION AND PERFORMANCE. m 0 oN no � <br /> CONTRACT DOCUMENTS WITH THE EXISTING CONDITIONS AT THE PROJECT-SITE z :]- D w Q N N 0 N <br /> 3. INSPECT EACH ITEM OF MATERIAL OR EQUIPMENT IMMEDIATELY PRIOR TO 4. PER CALGREEN SECTION 5.504.3, AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE 3 Y � _ 0 a- <br /> BEFORE STARTING CONSTRUCTION. REPORT ERRORS, INCONSISTENCIES OR OMISSIONS Q cn 0 w w <br /> DISCOVERED FOR CLARIFICATION. THE CONTRACTOR WILL BE RESPONSIBLE FOR CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL o -i a N v <br /> INSTALLATION. REJECT DAMAGED AND DEFECTIVE ITEMS. 0 a o o <br /> REPAIR OR CORRECTION COSTS IF WORK IS EXECUTED WITH KNOWLEDGE THAT ITDUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, <br /> INVOLVES AN ERROR, INCONSISTENCY OR OMISSION - WITHOUT THE ABOVE NOTICE. <br /> 4. COORDINATION WITH FIXTURES, FURNISHINGS & EQUIPMENT (FF&E): SHEET METAL, OR OTHER APPROVED METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH 5. IN THE EVENT OF CONFLICT OR AMBIGUITY WITHIN THE CONSTRUCTION DOCUMENTS, 5. REVIEW THE OWNERS SEPARATE CASEWORK/FIXTURES, FURNISHINGS, EQUIPMENT, & MAY ENTER THE SYSTEM. ARCHITECT OF RECORD: <br /> THE CONTRACTOR WILL BE DEEMED TO HAVE AGREED TO PROVIDE THE GREATER <br /> SIGNAGE DRAWINGS FOR UNIT SIZES WEIGHTS SERVICE-CONNECTIONS AND 5. PER CALGREEN SECTION 5.504.4.1 ADHESIVES ADHESIVE BONDING PRIMERS ADHESIVE PRIMERS SEALANTS s�o ARcy <br /> CLEARANCES REQUIRED - WHETHER FURNISHED OR INSTALLED BY THE CONTRACTOR ) �T <br /> SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH TABLE 5.504.4.1 AND 5.504.4.2. c, <br /> QUANTITY AND OR BETTER QUALITY OF MATERIALS AND OR WORK. OMISSIONS IN CRAIG S. <br /> / / OR OTHERS. VERIFY THAT REQUIRED ROUGH-INS, CONNECTIONS AND CLEARANCES � �� � <br /> THE DESCRIPTION OF THE WORK DO NOT RELIEVE THE CONTRACTOR FROM WILL BE PROVIDED. PROVIDE OPENINGS AND DELIVERY ACCESS FOR FF&E ITEMS, BLUME <br /> PROVIDING A COMPLETE PROJECT. AND PROVIDE STAGING SPACE FOR THEIR INSTALLATION. REPORT DISCREPANCIES OR SEALANT VOC LIMIT: N0. C-31661 <br /> OMISSIONS OF EQUIPMENT REQUIREMENTS PRIOR TO INSTALLATION. ARCHITECTURAL 250 REN.3/31/2021 <br /> GENERAL SCOPE OF WORK: MARINE DECK 760 ay <br /> 6. PROVIDE ALL HVAC, PLUMBING, GAS OR ELECTRIC SERVICE CONNECTIONS TO NONMEMBRANE ROOF 300 d0y �y <br /> 1. PERFORM ALL CONSTRUCTION WORK INDICATED OR OTHERWISE REQUIRED FOR CASEWORK / FIXTURES, SIGNAGE, OR EQUIPMENT INDICATED (WHETHER UNITS ARE ROADWAY 250 �o <br /> COMPLETION OF THE PROJECT - EXCEPT AS NOTED OTHERWISE. INSTALLED BY CONTRACTOR OR BY OTHERS). SINGLE-PLY ROOF MEMBRANE 450 <br /> 2. SCHEDULE AND COORDINATE THE WORK OF THE COMPLETE PROJECT TO ASSURE AN OTHER 420 <br /> EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF ALL ELEMENTS - WITH GENERAL EXECUTION OF THE WORK: <br /> 6. PER CALGREEN SECTION 5.504.4.3, ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE 0 <br /> PROVISIONS FOR ACCOMMODATING ITEMS TO BE INSTALLED LATER. 1. ESTABLISH AND MAINTAIN DURABLE MARKERS TO LOCATE ALL ELEMENTS OF THE 5.504.4.3. ui O Q <br /> 3. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, WORK, INCLUDING BUT NOT LIMITED TO PARTITIONS, CASEWORK, FIXTURES, o <br /> TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS EQUIPMENT AND LIGHT-FIXTURES, AND THEIR RELATED MECHANICAL, ELECTRICAL AND VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS: 110 <br /> OF THE WORK. PLUMBING CONNECTIONS. INDOOR CARPET ADHESIVES 50 ac <br /> 2. AT PROJECTIONS OF FINISHED SURFACES, INCLUDING PILASTERS OR THICKENED CARPET PAD ADHESIVES 50 <br /> 4. PROVIDE ALL REQUIRED NOTICES FOR INSPECTIONS AND APPROVALS OF THE WORK WALLS, RETURN ALL EXPOSED SURFACE FINISHES BACK TO THE PRIMARY SURFACE OUTDOOR CARPET ADHESIVES 150 <br /> BY THE AUTHORITY HAVING JURISDICTION (AHJ). THE MOST RESTRICTIVE CODE EVEN IF NOT SPECIFICALLY NOTED. WOOD FLOORING ADHESIVES 100 <br /> REQUIREMENTS AS INTERPRETED BY LOCAL OFFICIALS WILL APPLY. RUBBER FLOOR ADHESIVES 60 'kin5. VERIFY LOCATIONS OF EXISTING UTILITY SERVICE CONNECTIONS SERVING THE 3. PERFORM ALL CUTTING, PATCHING AND FITTING TO ACCOMMODATE CONSTRUCTION SUBFLOOR ADHESIVES 50 W <br /> WORK AND TO ACHIEVE THE INTENT OF THE CONSTRUCTION DOCUMENTS. CUT & CERAMIC TILE ADHESIVES 65 0 <br /> PROJECT BEFORE STARTING CONSTRUCTION. LOCATIONS OF EXISTING UTILITIES NOTED PATCH PARTITIONS FOR INSTALLATION OF PLUMBING OR ELECTRICAL SERVICES AND VCT AND ASPHALT TILE ADHESIVES 50 °r° sl <br /> ARE APPROXIMATE, AND MAY BE BASED ON UN-VERIFIED INFORMATION. PROVIDE ALL o <br /> FOR INSTALLATION OF WALL BLOCKING, IF NECESSARY. PROVIDE ESCUTCHEONS, DRYWALL AND PANEL ADHESIVES 50 w Q^ °' <br /> CONNECTIONS REQUIRED AT UTILITY CONNECTION POINTS AT NO ADDITIONAL COST TO O <br /> GROMMETS AND SIMILAR SURFACE CLOSURE OR FINISHED TRIMS AT EXPOSED a a o o g <br /> THE OWNER. COVE BASE ADHESIVES 50 W o a 3 <br /> PENETRATIONS OF FINISHED SURFACES. <br /> '5 <br /> MULTIPURPOSE CONSTRUCTION ADHESIVES 70 N 3 <br /> a � <br /> cj <br /> 6. PROVIDE SUBCONTRACTORS WITH A FULL-SET OF THE CONSTRUCTION DOCUMENTS STRUCTURAL GLAZING ADHESIVES 100 <br /> TO ENSURE COORDINATION BETWEEN ALL TRADES AND EACH SUBCONTRACTOR. 4. BRACE PARTITIONS, SUSPEND CEILINGS OR SOFFITS, AND BRACE PLATFORMS, <br /> SUSPENDED ITEMS OR SIMILAR CONSTRUCTION ONLY TO STRUCTURAL ELEMENTS SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 0 w <br /> 7. ALL CONSTRUCTION WORK MUST BE OF GOOD QUALITY - FREE FROM DEFECTS AND ABOVE - EVEN IF NOT SPECIFICALLY NOTED. DO NOT ANCHOR TO ROOF DECK, OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 0 "' 3 o " °N <br /> IN ACCORDANCE WITH REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS - OR THE PLUMBING / SPRINKLER PIPES, DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR SPECIALTY APPLICATIONS PVC WELDING 510 a o ;v v o `o'o <br /> ELEMENTS. CPVC WELDING 490 0 � a a o 0,5 <br /> WORK MAY BE CONSIDERED DEFECTIVE - AND SUBJECT TO CORRECTION OR c, o- N ° w ° <br /> ABS WELDING 325 ° L- L2 L'o O- <br /> J <br /> REPLACEMENT BY THE CONTRACTOR WITHIN A PERIOD OF ONE (1) YEAR AFTER COORDINATION WITH ADJACENT CONSTRUCTION: PLASTIC CEMENT WELDING 250 J °- o 0 v -, a o <br /> SUBSTANTIAL COMPLETION. o <br /> ADHESIVE PRIMER FOR PLASTIC 550 =° o a 3 E'o� <br /> 1. LIMIT WORK TO OCCUR WITHIN THE PROJECT SITE OR WITHIN OTHER AREAS ° <br /> INSTALLATION OF OWNER-FURNISHED PRODUCTS: CONTACT ADHESIVE 80 <br /> DESIGNATED OR APPROVED FOR USE BY THE OWNER / LANDLORD / OR QU ° °.�' i 0 <br /> DEVELOPER. CONNECT TO EXISTING UTILITY SERVICES BEYOND THE PROJECT-SITE IN SPECIAL PURPOSE CONTACT ADHESIVE 250 5 E� o� •o <br /> 1. COORDINATE, RECEIVE AT SITE, VERIFY RECEIPT, HANDLE, STORE ON-SITE (IF STRUCTURAL WOOD MEMBER ADHESIVE 140 ° o � o,a <br /> THE MOST EXPEDITIOUS MANNER POSSIBLE WITH MINIMAL DISTURBANCE OF EXISTING o <br /> REQUIRED), PROTECT AND INSTALL OWNER-FURNISHED PRODUCTS, AND PROVIDE ELEMENTS OR FINISHES. TOP AND TRIM ADHESIVE 250 N `o +,v°'3�' o <br /> U = ° <br /> SERVICE CONNECTIONS AS APPLICABLE. SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 -" ° L ° o+ <br /> tso° po0 <br /> 2. RESTORE ALL AREAS OF EXISTING LANDSCAPING (INCLUDING SPRINKLER SYSTEMS) PLASTIC FOAMS 50 (� • °: U o a o <br /> 2. NOTIFY THE OWNER WITHIN FIVE (5) DAYS OF RECEIPT OF ANY ITEMS ARE MISSING, DISTURBED DURING CONSTRUCTION TO ITS ORIGINAL CONDITION. POROUS MATERIAL (EXCEPT WOOD) 50 L U'N 0 1> ° <br /> DAMAGED OR OTHERWISE DEFECTIVE. LACK OF NOTIFICATION WILL BE CONSIDERED WOOD 30 _� o ° U °" ""01E ° <br /> PRESUMPTIVE PROOF THAT ALL ITEMS DID ARRIVE UNDAMAGED AND IN PROPER FINAL CLEANING: FIBERGLASS 80 o J� c a��i `o o 0 <br /> QUANTITIES, AND ANY REPLACEMENT OR REPAIRS NECESSARY WILL THEN BE THE <br /> RESPONSIBILITY OF THE CONTRACTOR. 6 <br /> 1. JUST BEFORE OWNER OCCUPANCY, CLEAN ALL SURFACES INCLUDING FIXTURES AND <br /> :� tno•v� ocv�io <br /> 7. PER CALGREEN SECTION 5.504.4.3.2, VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED U ° <br /> EQUIPMENT FOR THE OWNER'S USE AND OPERATION. POLISH GLASS AND PLUMBING a 6 U ° i °' ° <br /> 3. REPAIR DAMAGE TO OWNER-FURNISHED PRODUCTS CAUSED BY CONSTRUCTION AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE BUT IS NOT LIMITED TO THE O °.- ,2 0 <br /> FIXTURES TO BE WITHOUT NOTICEABLE STREAKS. VACUUM CLEAN FLOORS AND DAMP °- - ° N- ° <br /> OPERATIONS TO THE OWNER'S SATISFACTION. FOLLOWING: o o 0 a �, ` ,, <br /> WIPE WALLS, FIXTURES AND EQUIPMENT TO BE DUST-FREE WITHOUT STAINS, FILMS ° a° <br /> AND OTHER DISTRACTING SUBSTANCES. 1. MANUFACTURER'S PRODUCT SPECIFICATION ° ° =o `� _° a 00 <br /> v_, o <br /> N U L o fA CL'O <br /> 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS C- o-, rn a <br /> 2. CLEAN THE PROJECT SITE OF RUBBISH, LITTER AND OTHER FOREIGN SUBSTANCES. o 3 ° 3 0 <br /> BROOM CLEAN PAVED AREAS AND REMOVE STAINS, SPILLS AND OTHER FOREIGN <br /> DEPOSITS. RAKE GROUNDS THAT ARE NEITHER PAVED NOR PLANTED, TO A SMOOTH 8. PER CALGREEN SECTION 5.504.4.6, RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH THE VOC-EMISSION w = N= ° 0 `o <br /> EVEN-TEXTURED SURFACE. LIMITS DEFINED IN THE 2012 CHPS CRITERIA AND LISTEN ON ITS HIGH PERFORMANCE PRODUCTS DATABASE, Q v°i ar = w y" " <br /> PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGAURD CHILDREN & SCHOOLS w r- °= 0 o t ani t <br /> PROGRAM, CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE, OR <br /> SHALL MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION. <br /> 9. PER CALGREEN SECTION 5.508.1, RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE <br /> NONHAZARDOUS CONSTRUCTION OR DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2, OR <br /> 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS <br /> MORE STRINGENT. <br /> 10. PER CALGREEN SECTION 5.504.1.3, TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM <br /> SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR <br /> AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL <br /> AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN <br /> AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE <br /> 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE <br /> ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING <br /> ALTERATION AT THE CONCLUSION OF CONSTRUCTION. <br /> 11. PER CALGREEN SECTION 5.504.3, COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL <br /> EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE <br /> CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT <br /> AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, Q <br /> SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF <br /> DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. <br /> w <br /> 12. PER CALGREEN SECTION 5.504.7, ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR <br /> AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR Q ; z m <br /> INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR U (� o - <br /> REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY Y z 0 w Q <br /> AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS U 0 uj D w <br /> OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR U- UJ <br /> UJ <br /> POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. m o Lu 0 0 <br /> M w � a (' <br /> Z O w m <br /> N <br /> J N N <br /> V, Ld <br /> z z g c.) <br /> rn LLIWFE <br /> L o <br /> Ld <br /> ON W o o) w v~-i o <br /> J <br /> zGN1 . 0 <br /> N GENERAL NOTES <br />