PLUMBING GENERAL NOTES <br />1.SEE ARCHITECTURAL DRAWINGS FOR BUILDING DIMENSIONS AND EXACT LOCATIONS OF PLUMBING FIXTURES. <br />2.COORDINATE LOCATION OF PIPING WITH OTHER TRADES ON THIS PROJECT. <br />3.CONCEAL ALL PIPING IN WALL FURRING, PARTITIONS, ETC., EXCEPT AT MECHANICAL ROOMS. <br />4.PROVIDE BALL VALVES ON WATER PIPE BRANCHES TO EQUIPMENT AND PLUMBING FIXTURES. PROVIDE ACCESS PANELS <br />WHEN LOCATED IN FURRED SPACES OR ABOVE NON-REMOVABLE CEILINGS. ALL VALVES SHALL BE FULL LINE SIZE. <br />5.SEAL ALL PIPE PENETRATIONS THRU FLOORS WATERTIGHT. <br />6.PROVIDE GAS SHUT-OFF VALVE, UNION AND DIRT LEG AT EACH GAS CONNECTION TO MECHANICAL EQUIPMENT. <br />7.DOMESTIC HOT WATER HEATERS SHALL BE SEISMICALLY SECURED TO BUILDING STRUCTURE WITH ADEQUATE <br />STRUCTURAL SUPPORT WITH ANCHOR BOLTS TO WITHSTAND 0.29 LATERAL AND VERTICAL LOADS. <br />8.PRIOR TO ANY SOLENOID VALVE, QUICK CLOSING VALVE, ETC. PROVIDE AND INSTALL SHOCK ABSORBER OF REQUIRED <br />SIZE. <br />9.PENETRATIONS OF RATED ASSEMBLIES SHALL BE FIRE-STOPPED. FIRE STOPPING SHALL BE AN APPROVED MATERIAL OF <br />THE ENFORCING AGENCY. <br />10.OFFSET VENTS THRU ROOF 10 FEET MINIMUM FROM AIR INTAKES AND 4 FEET FROM OUTSIDE WALLS. <br />11.CONDENSATE DRAIN LINE CONNECTIONS TO MECHANICAL UNITS SHALL INCLUDE MINIMUM 4" DEEP "P" TRAP AND <br />CLEANOUTS AT ALL OFFSETS. <br />12.ALL MECHANICAL UNITS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. SEE "M" SHEETS. <br />13.OFFSET ALL RISERS AND DROPS TO AVOID PENETRATIONS AT TOP PLATES. <br />14.FIELD VERIFY EXACT SIZES, LOCATIONS AND ELEVATIONS OF ALL PIPING CONNECTIONS, OTHER WORK, ETC., PRIOR TO <br />TRENCHING OR INSTALLING OF ANY NEW WORK. <br />15.BUILDING SEWER, WATER AND STORM DRAIN RUN APPROXIMATELY 5' MIN. FROM BUILDING, SECTION 15400 APPLIES TO <br />UTILITIES IN THE BUILDING, UNDER THE BUILDING AND TO 5' OUTSIDE THE BUILDING, BEYOND THE 5' OUTSIDE OF THE <br />BUILDING SECTION 02700 GOVERNS. <br />16. CONTRACTOR TO COORDINATE PLUMBING REQUIREMENTS FOR FOOD SERVICE EQUIPMENT. REFER TO PLUMBING NOTES <br />ON SHEET FS2.00. <br />FIRESTOPPING <br />1. PACK THE ANNULAR SPACE BETWEEN THE PIPE SLEEVES AND THE PIPE THROUGH ALL FLOORS AND WALLS WITH <br />UL LISTED FIRE STOP, AND SEALED AT THE ENDS. ALL PIPE PENETRATIONS SHALL BE UL LISTED, HILTI, 3M <br />PRO-SET, OR EQUAL. <br />A.INSTALL FIRE CAULKING BEHIND MECHANICAL SERVICES INSTALLED WITHIN FIRE RATED WALLS, TO <br />MAINTAIN CONTINUOUS RATING OF WALL CONSTRUCTION. <br />2. PROVIDE SPECSEAL SYSTEMS UL FIRE RATED SLEEVE/COUPLING PENETRATORS FOR EACH PIPE PENETRATION OR <br />FIXTURE OPENING PASSING THROUGH FLOORS, WALLS, PARTITIONS OR FLOOR/CEILING ASSEMBLIES. ALL <br />PENETRATORS SHALL COMPLY WITH UL FIRE RESISTANCE DIRECTORY (LATEST EDITION), AND IN ACCORDANCE <br />WITH CHAPTER 7, CBC REQUIREMENTS. <br />3. SLEEVE PENETRATORS SHALL HAVE A BUILT IN ANCHOR RING FOR WATERPROOFING AND ANCHORING INTO <br />CONCRETE POURS OR USE THE SPECIAL FIT CORED HOLE PENETRATOR FOR CORED HOLES. <br />4. COPPER AND STEEL PIPING SHALL HAVE SPECSEAL PLUGS ON BOTH SIDES OF THE PENETRATOR TO REDUCE <br />NOISE AND TO PROVIDE WATERPROOFING. <br />5. ALL ABOVE SYSTEMS TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 6. <br />ALTERNATE FIRESTOPPING SYSTEMS ARE ACCEPTABLE IF APPROVED EQUAL. HOWEVER, ANY DEVIATION FROM <br />THE ABOVE SPECIFICATION REQUIRES THE CONTRACTOR TO BE RESPONSIBLE FOR DETERMINING THE <br />SUITABILITY OF THE PROPOSED PRODUCTS AND THEIR INTENDED USE, AND THE CONTRACTOR SHALL ASSUME <br />ALL RISKS AND LIABILITIES WHATSOEVER IN CONNECTION THEREWITH. <br />MEP COMPONENT ANCHORAGE NOTE <br />ALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS <br />ON THE DSA APPROVED CONSTRUCTION DOCUMENTS. WHERE NO DETAIL IS INDICATED, THE FOLLOWING <br />COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE AND DISPLACEMENT REQUIREMENTS <br />PRESCRIBED IN THE 2016 CBC, SECTIONS 1616A.1.18 THROUGH 1616A.1.26 AND ASCE 7-10 CHAPTER 13, 26 AND 30. <br />1. ALL PERMANENT EQUIPMENT AND COMPONENTS. <br />2. TEMPORARY OR MOVABLE EQUIPMENT THAT IS PERMANENTLY ATTACHED (e.g. HARD WIRED) TO THE <br />BUILDING UTILITY SERVICES SUCH AS ELECTRICITY, GAS OR WATER. <br />3. MOVABLE EQUIPMENT WHICH IS STATIONED IN ONE PLACE FOR MORE THAN 8 HOURS AND HEAVIER THAN 400 <br />POUNDS ARE REQUIRED TO BE ANCHORED WITH TEMPORARY ATTACHMENTS. <br />THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE POSITIVELY ATTACHED TO THE STRUCTURE, <br />BUT THE ATTACHMENT NEED NOT BE DETAILED ON THE PLANS. THESE COMPONENTS SHALL HAVE FLEXIBLE <br />CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT. <br />A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS LOCATED 4 FEET OR LESS <br />ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT. <br />B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTION SYSTEMS, LESS THAN 5 <br />POUNDS PER FOOT, WHICH ARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL. <br />FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION SHALL BE <br />SUBJECT TO THE APPROVAL OF THE DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE OR STRUCTURAL <br />ENGINEER DELEGATED RESPONSIBILITY AND THE DSA DISTRICT STRUCTURAL ENGINEER. THE PROJECT INSPECTOR <br />WILL VERIFY THAT ALL COMPONENTS AND EQUIPMENT HAVE BEEN ANCHORED IN ACCORDANCE WITH ABOVE <br />REQUIREMENTS. <br />PIPING, DUCTWORK & ELECTRICAL <br />DISTRIBUTION SYSTEM BRACING NOTE <br />OPTION 2: SHALL COMPLY WITH THE APPLICABLE OSHPD PRE-APPROVED (OPM #) <br />#0043-13 BY MASON INDUSTRIES, INC. <br />MECHANICAL PIPING (MP), MECHANICAL DUCTS (MD), PLUMBING PIPING (PP), ELECTRICAL DISTRIBUTION <br />SYSTEMS (E): <br />MP <br />MP <br />MP <br />MD <br />MD <br />MD <br />PP <br />PP <br />PP <br />E <br />E <br />PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES <br />AND DISPLACEMENTS PRESCRIBED IN ASCE 7-10 SECTION 13.3 AS DEFINED IN ASCE 7-10 SECTION 13.6.5.6, <br />13.6.7, 13.6.8, AND 2016 CBC, SECTIONS 1616A.1.23, 1616A.1.24, 1616A.1.25 AND 1616A.1.26. <br />THE METHOD OF SHOWING BRACING AND ATTACHMENTS TO THE STRUCTURE FOR THE IDENTIFIED DISTRIBUTION <br />SYSTEM ARE AS NOTED BELOW. WHEN BRACING AND ATTACHMENTS ARE BASED ON PREAPPROVED <br />INSTALLATION GUIDE (e.g., SMACNA OR OSHPD OPM). COPIES OF THE BRACING SYSTEM INSTALLATION GUIDE <br />OR MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO THE START OF AND DURING THE HANGING AND <br />BRACING OF THE DISTRIBUTION SYSTEMS. THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE <br />ADEQUACY OF THE STRUCTURE TO SUPPORT THE HANGER AND BRACE LOADS. <br />OPTION 3: SHALL COMPLY WITH THE SMACNA SEISMIC RESTRAINT MANUAL. OSHPD <br />EDITION (2009), INCLUDING ANY ADDENDA. FASTENERS AND OTHER ATTACHMENTS <br />NOT SPECIFICALLY IDENTIFIED IN THE SMACNA SEISMIC RESTRAINT MANUAL, OSHPD <br />EDITION, ARE DETAILED ON THE APPROVED DRAWINGS WITH PROJECT SPECIFIC NOTES <br />AND DETAILS. THE DETAILS SHALL ACCOUNT FOR THE APPLICABLE SEISMIC HAZARD <br />LEVEL ____ AND CONNECTION LEVEL ____ FOR THE PROJECT AND CONDITIONS. <br />OPTION 1: DETAILED ON THE APPROVED DRAWINGS WITH PROJECT SPECIFIC NOTES <br />AND DETAILS <br />R GPR <br />GW GREASE WASTE PIPINGGW <br />GAS PRESSURE REGULATOR <br />IW <br />MG <br />OH <br />(N) , (E) <br />(NTS) <br />OFL <br />OD <br />IW <br />MG <br />OFL <br />DESCRIPTION <br />ABOVE CEILING <br />ABOVE FLOOR , BELOW FLOOR <br />ABOVE FINISHED FLOOR <br />BALL VALVE <br />BRANCH - BOTTOM CONNECTION <br />BRANCH - TOP CONNECTION <br />ACCESS DOOR , ACCESS PANEL <br />ABBREVIATION <br />AF , BF <br />AFF <br />ABC <br />SYMBOL <br />BV <br />AD , AP <br />PLUMBING LEGEND <br />WH <br />P & TRV <br />RV or P&TRV <br />PRV <br />RWL <br />(R) , (D) <br />SD <br />W OR SS <br />RD <br />P & TRV <br />SD <br />RWL <br />TP <br />UN <br />TYP <br />V <br />WHA <br />VB <br />WCO <br />TP <br />V , VR , VTR <br />CAP ON END OF PIPE <br />BRANCH - SIDE CONNECTION <br />COLD WATER <br />CONDENSATE DRAIN LINE <br />COP <br />or <br />CW <br />CD <br />CO <br />CD <br />EXISTING TO BE REMOVED <br />FIXTURE UNIT <br />FLOOR DRAIN <br />FLOOR SINK <br />FLOOR CLEANOUT <br />FLOW IN DIRECTION OF ARROW <br />FINISHED FLOOR ELEVATION <br />FCO <br />FS <br />FD <br />FU <br />FF= <br />CO CLEANOUT CO <br />POC <br />INDIRECT DRAIN , CONDENSATE DRAIN <br />MEDIUM PRESSURE GAS <br />NEW , EXISTING <br />NOT TO SCALE <br />OVERHEAD <br />PRESSURE & TEMPERATURE RELIEF VALVE PIPING <br />RECESSED BOX HOSE BIBB OR WALL HYDRANT <br />RELIEF VALVE OR PRESSURE & TEMPERATURE RELIEF VALVE <br />RISER DOWN (ELBOW) <br />RISER UP (ELBOW) <br />PRESSURE REDUCING VALVE <br />RISE , DROP <br />SOIL, WASTE OR SANITARY SEWER <br />STORM DRAIN <br />OVERFLOW RAINWATER LEADER <br />VENT PIPING <br />UNION OR FLANGE <br />TRAP PRIMER <br />TRAP PRIMER PIPING <br />TYPICAL <br />VENT , VENT RISER , VENT THRU ROOF <br />VALVE IN VALVE BOX <br />WATER HAMMER ARRESTER <br />VALVE IN RISER (TYPE AS INDICATED OR NOTED) <br />POINT OF CONNECTION, NEW TO EXISTING <br />SOLENOID VALVE WITH MOTOR ACTUATOR <br />WALL CLEANOUT <br />RAINWATER LEADER <br />ROOF DRAIN <br />OVERFLOW DRAIN <br />GAS - LOW PRESSURE <br />GAS COCK , PLUG COCK <br />FLUSH VALVE , FLUSH TANK <br />FROM ABOVE , TO ABOVE <br />FROM BELOW , TO BELOW <br />GATE VALVE, BALL VALVE, SHUT OFF VALVE <br />HOSE BIBB <br />GRADE CLEANOUT, EXTERIOR <br />GALLONS PER MINUTE <br />HOT WATER PIPING <br />G <br />GSCK , PC <br />(FA) , (TA) <br />(FB) , (TB) <br />FV , FT <br />G <br />GCO <br />GPM <br />HB <br />HW <br />PUMPED CONDENSATE DRAINPCDPCD <br />HOT WATER RETURNHWR <br />&CW & HW FIXTURE CONNECTION STUB OR ANGLE STOP <br />DN DOWN <br />UG UNDERGROUND <br />UR URINAL <br />S or SK SINK <br />IE or INV INVERT ELEVATION <br />L LAVATORY SINK <br />LL, DL LONGEST LENGTH (GAS), DEVELOPED LENGTH <br />WC WATER CLOSET <br />WH WALL HYDRANT <br />WSFU WATER SUPPLY FIXTURE UNIT <br />DFU DRAIN FIXTURE UNIT <br />ELECTRIC WATER HEATEREWH <br />EXISTING TO REMAIN(E) <br />FU <br />EXISTING TO BE ABANDONED, CAP WHERE SHOWN(E) <br />BELOW FINISHED FLOORBFF <br />(FA) , (TA) <br />(FB) , (TB) <br />FV , FT TABLE 2.1 <br />GAS LOAD COMPUTATION <br />BUILDING EQUIPMENT EQUIPMENT DESCRITION MBH EACH QTY MBH TOTAL MBH <br />TOTAL/GPR <br />BDEF WAC-B1 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-D1 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-D2 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-E1 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-E2 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-E3 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-E4 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-F1 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-F2 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-F3 MECHANICAL AC UNIT 1.00 50 50.00 <br />BDEF WAC-F4 MECHANICAL AC UNIT 1.00 50 50.00 <br />BRANCH 1 550.00 <br />/////////////////////////////////////// <br />KITCHEN P5 OPEN BURNER WITH OVEN 1.00 163 163.00 <br />KITCHEN P7 TILT SKILLET 1.00 144 144.00 <br />KITCHEN P8 STEAMER 2.00 60 120.00 <br />KITCHEN P9 DOUBLE STACK OVEN 2.00 63 126.00 <br />KITCHEN P10 DOUBLE STACK OVEN 2.00 60 120.00 <br />KITCHEN GWH-A1 GAS WATER HEATER 1.00 200 200.00 <br />KITCHEN (E)AC-10 MECHANICAL AC UNIT 1.00 250 250.00 <br />KITCHEN AC UNIT MECHANICAL AC UNIT 1.00 200 200.00 <br />BRACH 2 1323.00 <br />TOTAL 1873.00 <br />MIN METER <br />CAPACITY 3000.00 <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212KITCHEN RENOVATIONJOE SERNA SCHOOLSHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />REVISIONS BY <br />19-32-050 <br />RL <br />TD <br />AS NOTED <br />191009.00 <br />PM - DESIGN TEAM PROJECT NO. <br />MCM - RL/JSV <br />C A <br />RANCHO CORDOVA,CALIFORNIA <br />ENGINEERING CONSULTANTS, INC. <br />P I T A L <br />\\capsac.lan\network\Project_Docs\2019\191009.00\1200 Drawings\1205 AutoCAD Project Files\P0.1.dwg - April 10, 2020 12:46 PM - Joel Valencia04/10/2020 <br />FILE NO. 39-50 APP NO. 02-118041 <br />P0.1 PLUMBING LEGEND,SCHEDULE & NOTES