Laserfiche WebLink
SLOPE TO DRAIN <br />WATERTIGHT SHEET <br />DETAIL "A" <br /> " CW <br />SEAL WATERTIGHT <br />UNION <br />SEE DETAIL "A" <br />STUD WALL <br />CW PIPE IN WALL <br /> " BALL VALVE <br />TRAP PRIMER <br />SECURE TO STUDS <br />ACCESS PANEL <br /> " CWD <br />FIN FLOOR <br />FLOOR DRAIN <br /> " CW TO TRAP <br />CONNECT AS REQ'D <br /> " BELOW FLOOR <br />SEAL WATERTIGHT <br />METAL BOX <br />6" min.BOTTOM OF BOX TO <br />EXTEND TO BE FLUSH <br />WITH WALL FINSH <br />1 1/2" SPUD <br />VACUUM BREAKER TUBE <br />CHECK VALVE <br />6" MIN. <br />PER CPC 603.5.1 <br />VALVE STYLE MAY VARY <br />INSTALL FLUSH VALVE PER MANUFACTURER'S INSTRUCTIONS. <br />NOTES: <br />VERIFY ROUGH IN OF WATER SUPPLY TO ALLOW FOR PROPER VALVE INSTALLATION. <br />TOP OF TOILET <br />ADAPTER AND CONC. LID. <br />18" ADS EXTENSION, ADS <br />VALVE BOX - F8 BOX WITH <br />DRAIN FROM MECH. <br />CONDENSATE <br />"CHRISTY" F22 CURB <br />GRADE AS SOON AS POSSIBLE. <br />AS LOW AS POSSIBLE AND BELOW <br />ROUTE CONDENSATE DRAIN THRU WALL <br />NOTE: <br />GRADE <br />WITH CONCRETE <br />MOUNT BOX FLUSH <br />2" OF CD LINE BOTTOM. <br />PEA GRAVEL TO WITHIN <br />FILL WITH WASHED <br />PAVING <br />UNIT, TYP. <br />MIN. 4" DEEP <br />ROUND OR SQUARE, <br />CONC. PERIMETER, <br />6"CONCRETE <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212KITCHEN RENOVATIONJOE SERNA SCHOOLSHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />REVISIONS BY <br />19-32-050 <br />RL <br />TD <br />AS NOTED <br />191009.00 <br />PM - DESIGN TEAM PROJECT NO. <br />MCM - RL/JSV <br />C A <br />RANCHO CORDOVA,CALIFORNIA <br />ENGINEERING CONSULTANTS, INC. <br />P I T A L <br />\\capsac.lan\network\Project_Docs\2019\191009.00\1200 Drawings\1205 AutoCAD Project Files\P5.2.dwg - April 10, 2020 12:46 PM - Joel Valencia04/10/2020 <br />FILE NO. 39-50 APP NO. 02-118041 <br />P5.2 PLUMBINGDETAILSADAPTER AND CONC. LID. <br />18" ADS EXTENSION, ADS <br />VALVE BOX - F8 BOX WITH <br />DRAIN FROM MECH. <br />CONDENSATE <br />"CHRISTY" F22 CURB <br />GRADE AS SOON AS POSSIBLE. <br />AS LOW AS POSSIBLE AND BELOW <br />ROUTE CONDENSATE DRAIN THRU WALL <br />NOTE: <br />GRADE <br />WITH CONCRETE <br />MOUNT BOX FLUSH <br />2" OF CD LINE BOTTOM. <br />PEA GRAVEL TO WITHIN <br />FILL WITH WASHED <br />PAVING <br />UNIT, TYP. <br />MIN. 4" DEEP <br />ROUND OR SQUARE, <br />CONC. PERIMETER, <br />6"CONCRETE <br />GAS TRAIN <br />CONNECT TO <br />CONNECT TO <br />CONDENSATE DRAIN <br />PAN ON UNIT <br />LINE SIZE GAS SHUT-OFF VALVE. <br />PROVIDE LINE SIZE X 6" LONG <br />DIRT LEG WITH REMOVABLE <br />GASTIGHT CAP DOWNSTREAM <br />OF SHUT OFF VALVE BEFORE <br />THE FLEX CONNECTOR OR <br />UNION. SEE ALSO CPC 1212.8 <br />NOTE: <br />PROVIDE FLEXIBLE CONNECTORS WHEN <br />MECHANICAL UNIT IS ON A SPRING CURB. <br />SEE MECHANICAL DRAWINGS. <br />AC UNIT ON ROOF <br />CURB <br />G <br />PROVIDE 3"MIN CLEARANCE <br />BELOW DIRT LET <br />4" DEEP MINIMUM P-TRAP. <br />SEE AC UNIT INSTALLATION <br />INSTRUCTIONS. <br />1/8"PINHOLE ON <br />REMOVABLE VENT CAP <br />A UNION OR FLANGED <br />CONNECTOR SHALL BE <br />PROVIDED DOWNSTREAM FROM <br />THE VALVE TO PERFORM <br />REMOVAL OF APPLIANCE <br />CONTROLS. CPC 1212.5