__SYMBOLS, NOTES,
<br />ABBREVIATIONS,
<br />SCHEDULESE0.1A AMPERESAC ALTERNATING CURRENTA.F.F. ABOVE FINISHED FLOORAWG AMERICAN WIRE GAUGEBKR BREAKERC. CONDUITCKT.BRKR.CIRCUIT BREAKERCDCANDELACKT CIRCUITC.O. CONDUIT ONLY, WITH PULL WIRE(E) EXISTINGEM EMERGENCY(ER) EXISTING RELOCATEDEMT ELECTRICAL METALLIC CONDUIT(F) FUTUREFACP FIRE ALARM CONTROL PANELFAPSFIRE ALARM POWER SUPPLYGA. GAUGEGND GROUNDGFI GROUND FAULT CIRCUIT INTERRUPTERHP HORSEPOWERHVAC HEATING, VENTILATING AND AIRCONDITIONINGLTG. LIGHTMAX. MAXIMUMMDF MAIN DISTRIBUTION FRAMEMIN. MINIMUMNNEUTRAL(N) NEWNEMA NATIONAL ELECTRICALMANUFACTURERS ASSOCIATIONN.I.C.NOT IN CONTRACTPFB PROVISIONS FOR FUTURE CIRCUITBREAKER(R) REMOVE(RE) RELOCATE EXISTINGRCPT. RECEPTACLES.M.SSHEET METAL SCREWSWBD SWITCHBOARDSYS SYSTEMTYP.TYPICALUG UNDERGROUNDUL UNDERWRITERS LABORATORYV VOLTVA VOLT-AMPERESW WATTWP WEATHER PROTECTEDXFMR TRANSFORMERABBREVIATIONSTHE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE POWER FOR NEW KITCHENEQUIPMENT, NEW HVAC EQUIPMENT, NEW LIGHTING, IN RENEWED KITCHEN. EXISTING FIRE ALARM, DATA,INTRUSION AND VOICE SYSTEMS WILL BE REVISED AND ADJUSTED TO CONFIRM TO RENEWED KITCHEN.SHOULD ANY CONDITIONS DEVELOP, NOT COVERED BY THE CONTRACT DOCUMENTS, WHEREIN THEFINISHED WORK WILL NOT COMPLY WITH ALL REQUIRED CODES, A CHANGE ORDER DETAILING ANDSPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED TO, AND APPROVED BY, THE AGENCY BEFOREPROCEEDING WITH THE WORK.PROJECT DESCRIPTIONElectrical Engineers Lighting Designers100 Howe Ave., Suite 235NSacramento, CA 95825-8217Tel: (916) 923-4400 Fax: (916) 923-4410www.mneilsengineering.comPROJECT #: 19276.2104/09/2020SHEETSOF730 Howe Avenue, Suite 450
<br />Sacramento, CA 95825
<br />Phone: 916.921.2112
<br />Fax: 916.921.221268KITCHEN RENOVATION
<br />HOUSTON (SERNA) SCHOOLSHEET NO.CONSULTANTUPDATEDCADFILECHECKEDDRAWNSCALEPROJECT NO. DATE04/10/2020REVISIONSBY19-32-050SLHSLHFILE NO. 39-50 APP NO. 02-118041DESCRIPTIONMANUFACTURERCATALOG NO.TYPEVOLTAGEMOUNTINGLUMINAIRE SCHEDULE REMARK NOTES:REFER TO PLANS FOR BATTERY OPERATED EMERGENCY DRIVER.REMARKNOTE No.1LUMINAIRE SCHEDULELAMPBDESCRIPTIONAVISIONEERING-VISCORT-BARTROFFER - KITCHEN120 VOLTLED, 52 WATTS,4000K, 80 CRILRT-A-C29-2X4-LED-8-40K-063L-P04-X5CERTOLUXSURFACESURFACE, VANDAL120 VOLTLED, 22 WATTS,4000K, 80 CRIVRSE-3556-24-LED-8-40K-24L13ENCLOSED LUMINAIRE - SURFACE MOUNTED (LETTER "a" DENOTES SWITCH FUNCTION,NUMBER "2" DENOTES CIRCUIT NUMBER - TYPICAL FOR ALL LUMINAIRES UNLESS NOTEDOTHERWISE).ENCLOSED LUMINAIRE - CEILING LAY-INEMERGENCY ENCLOSED LUMINAIREEXISTING LUMINAIRE TO REMAINEXISTING LUMINAIRE TO BE REMOVEDLUMINAIRE DESIGNATION WITH LAMP QUANTITY AND WATTAGE. SEE LUMINAIRE SCHEDULE.SINGLE POLE TOGGLE SWITCH, +45" A.F.F. - "a" LETTER DENOTES SWITCH FUNCTION,TYPICAL FOR ALL SWITCHES UNLESS NOTED OTHERWISETHREE-WAY TOGGLE SWITCHDIMMER SWITCHOCCUPANCY SENSOR SWITCH WITH MANUAL OVERRIDE - WALL MOUNTED AT +45" A.F.F.UNLESS NOTED OTHERWISEOCCUPANCY AREA SENSOR SWITCHLIGHTING ROOM CONTROLLER - MOUNTED IN ACCESSIBLE CEILING AREA, UNLESS NOTEDOTHERWISEJUNCTION BOX - SIZE AS REQUIRED BY CODEDUPLEX CONVENIENCE OUTLET - NEMA 5-20R +18" A.F.F. TYPICAL FOR ALL CONVENIENCEOUTLETS, UNLESS NOTED OTHERWISE (LETTER "A" SHOWN ADJACENT TO OUTLETDESIGNATES MOUNTED HORIZONTALLY ABOVE COUNTER).QUADPLEX CONVENIENCE OUTLET - NEMA 5-20RSPECIAL RECEPTACLE AS SHOWN ON PLANSSPEAKER - WALL MOUNTED, REFER TO ARCHITECTURAL ELEVATIONS FOR EXACTLOCATION AND MOUNTING HEIGHT.CLOCK OUTLET - WALL MOUNTED REFER TO ARCHITECTURAL ELEVATIONS FOR EXACTLOCATION AND MOUNTING HEIGHT.CONDUIT RUN CONCEALED IN CEILINGS OR WALLS. NUMBER OF HASH MARKS DENOTESQUANTITY OF WIRES. CURVED HASH MARK DENOTES QUANTITY OF #12 GREEN GROUNDWIRES. CONDUCTORS OTHER THAN #12 ARE INDICATED ON PLANS. NO HASH MARKSDENOTES 2 #12 AWG AND 1 #12 GREEN GROUND IN 1/2" CONDUIT. TYPICAL FOR ALLCONDUITS.CONDUIT HOMERUN TO PANELBOARD, SWITCHBOARD OR TERMINAL CABINETEXISTING CONDUIT AND WIRINGPANELBOARD - SURFACE MOUNTEDPANELBOARD - FLUSH MOUNTEDTERMINAL CABINETSWITCHBOARD, DISTRIBUTION PANEL, OR MOTOR CONTROL CENTEREQUIPMENT DISCONNECT SWITCH - EXTERNALLY OPERATED, FUSED WITH FUSE SIZE TOMATCH EQUIPMENT NAMEPLATEEQUIPMENT DISCONNECT SWITCH - EXTERNALLY OPERATED, NON-FUSIBLEDRAWING SHEET NUMBERED NOTE DESIGNATION - APPLIES TO NUMBERED NOTE ON SAMESHEETDRAWING PLAN OR DETAIL DESIGNATION - "1" OR "A" DENOTES PLAN OR DETAIL NUMBER,"E-1" DENOTES SHEET NUMBER1E-1A2/32SECURITY SYSTEM KEYPAD AND OUTLET BOX +45" A.F.F. UNLESS NOTED. PROVIDE 3/4"CONDUIT STUB. SEE NOTE 4.SYMBOL LIST NOTES:1.EXISTING ELECTRICAL EQUIPMENT, OUTLETS, AND DEVICES ARE SHOWN THE SAME AS NEW, EXCEPTLIGHTLY AND ACCOMPANIED BY (E). SUCH ELECTRICAL EQUIPMENT, OUTLETS, AND DEVICES ARE TOREMAIN AS IS, UNLESS OTHERWISE NOTED ON PLAN OR SPECIFICATION.2.ELECTRICAL OUTLET BOXES MOUNTED ON OPPOSITE SIDES OF FIRE-RATED WALLS OR PARTITIONSSHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES PER CBC 2016,WHETHER SHOWN ON THE PLANS OR NOT.3.VERIFY ON SITE THAT ALL PANELBOARDS HAVE MINIMUM WORKING SPACES PER CODE AND THAT THEDEDICATED PANELBOARD SPACES ARE CLEAR OF ALL DUCTS, PIPING AND EQUIPMENT FOREIGN TOTHE PANEL BOARDS. NOTIFY THE ENGINEER FOR CORRECTIVE ACTION IN THE EVENT THAT FOREIGNOBJECTS IMPEDE THE DEDICATED PANELBOARD AREAS.SECURITY SYSTEM DOOR OR WINDOW CONTACT. PROVIDE 1/2" CONDUIT STUB.EXISTING PANELBOARD - SURFACE MOUNTEDEXISTING PANELBOARD - FLUSH MOUNTEDFIRE ALARM HEAT DETECTOR - CEILING MOUNTED. "AC" INDICATE THAT DETECTOR ISMOUNTED IN ACCESSIBLE ABOVE CEILING / ATTIC SPACE. "194°" INDICATE HIGHTEMPERATURE HEAT DETECTOR.FIRE ALARM AUDIBLE DEVICE, +90" A.F.F. UNLESS OTHERWISE NOTED. DEFAULT DEVICE IS ASPEAKER.END OF LINE RESISTORMASTER FIRE ALARM CONTROL PANELREMOTE FIRE ALARM POWER SUPPLYYYFIRE ALARM SMOKE DETECTOR - CEILING MOUNTED. THE DEFAULT TYPE ISPHOTOELECTRICFIRE ALARM AUDIO / VISUAL DEVICE, +80" A.F.F. DEFAULT AUDIO DEVICE IS A SPEAKER. "YY"INDICATES STROBE CANDELA RATING.FIRE ALARM REMOTE ANNUNCIATOR PANEL - FLUSH MOUNTEDXDATA OUTLET - FLUSH IN WALL +18" A.F.F. NUMBER IN PARENTHESIS INDICATES NUMBER OFDATA JACKS.(2)FLEXIBLE CONDUIT CONCEALED. NUMBER OF HASH MARKS DENOTES QUANTITY OF WIRES.CURVED HASH MARK DENOTES QUANTITY OF #12 GREEN GROUND WIRES. CONDUCTORSOTHER THAN #12 ARE INDICATED ON PLANS. NO HASH MARKS DENOTES 2 #12 AWG AND 1 #12GREEN GROUND IN 1/2" MINIMUM DIAMETER CONDUIT.EXISTING CONDUIT TO BE REMOVED OR ABANDONED, REMOVE WIRES. COORDINATE WITHOWNER.MECHANICAL EQUIPMENT DESIGNATION - SEE MECHANICAL PLANSJVISUAL FIRE ALARM DEVICE +80" A.F.F. - WALL MOUNTED (LAMP, SIGNAL LIGHT, INDICATORLAMP, STROBE), "YY" = CANDELA RATINGYYEOLK1FAPSANNFACPEQ1MMFIRE ALARM MONITOR MODULEELECTRICAL SYMBOL LISTa2DIMMER SWITCH WITH INTEGRAL OCCUPANCY SENSOR - WALL MOUNTED AT +45" A.F.F.UNLESS NOTED OTHERWISE
|