Laserfiche WebLink
TEMPERATURE SWITCH <br />TYPICAL ENERGY MANAGEMENT SYSTEM <br />TOUCH-SCREEN <br />USER INTERFACE <br />ENERGY MANAGEMENT SYSTEM <br />ROOM TEMP SENSOR <br />Room Temperature Sensor <br />-Install on wall somewhere <br />in the space but not directly <br />under the hood or close to <br />an appliance so that the <br />reading is not affected by it. <br /> RISER <br /> TO DUCT OR <br /> TACK WELDED <br /> RING TO BE <br />**NOTE: EXTENSION <br />Extension Ring Cover <br />100-BW <br />**NOTE: EXTENSION <br /> RING TO BE <br /> TACK WELDED <br /> TO DUCT <br />1 1/8" - 1 1/4" Diameter Hole <br />1/2" Quik Seal (Nut) <br />Part #32-00002 <br />1/2" Quik Seal (Lock Washer) <br />Part #32-00002 <br />Grease Duct <br />(External Surface) <br /> Thermistor has 2 wires that connect to control cabinet <br />NOTES: One aensor per Exhaust Riser <br />Extension Ring <br />Cover <br />Part # 52C1STC <br />1/2" Quik Seal (Gasket) <br />Part # 32-00002 <br />1/2" Quik Seal (Adapter Body) <br />Part # 32-00002 <br />THERMISTOR INSTALLATION DETAIL CABINET MOUNTED DCV <br />FANSLIGHTS <br />GAS RESET <br />MOUNTS IN STANDARD DOUBLE <br />GANG JUNCTION BOX <br />ALARM INDICATING LCD SCREEN. <br />BUTTON FUNCTIONS VARY BY <br />MODEL TYPE. <br />CAT-5 CONNECTION ON REVERSE. <br />CONNECTED TO HOOD CONTROL <br />PANEL. <br />All fans must have inverter duty motors, <br />and all conduits from the load side of the <br />VFDs must be seperate and dedicated. <br />ELECTRICAL PACKAGE - Job#4025056 <br />1 DCV-1111 Utility Cabinet Left 08 - Ship Loose w/ <br />Prewire <br />1 Light <br />1 Fan <br />Smart Controls DCV <br />Exhaust <br />Supply <br />3 <br />3 <br />3.000 <br />2.000 <br />208 <br />208 <br />10.2 <br />6.1 <br />NO.TAG PACKAGE #LOCATION <br />SWITCHES <br />LOCATION QUANTITY <br />OPTION <br />FANS CONTROLLED <br />TYPE ΙΈ H.P.VOLT FLA <br />CASlink Monitor and Control <br />- Hood control panel to support communications to cloud-based Building <br />Management System. <br />- Hood Control Panel to allow cloud-based Building Management System to <br />monitor real time parameters outlined as MONITOR in the points list. <br />- Hood Control Panel to allow cloud-based Building Management System to <br />control parameters outlined as CONTROL in the points list. <br />- Hood Control Panel to allow cloud-based Building Management System to <br />implement SYSTEM ECONOMIZER control strategies for fully integrated Building <br />Management. <br />MONITORING AND CONTROL POINTS LIST <br /> SC PackagesDCV Packages Function <br />Room Temperature(s)MONITOR <br />Duct Temperature(s)MONITOR <br />MUA DIscharge Temperature MONITOR <br />Kitchen RTU Discharge Temperature MONITOR <br />Controller Faults MONITOR <br />Fan Faults MONITOR <br />Fan Status MONITOR <br />PCU Faults MONITOR <br />PCU Filter Clog Percentages MONITOR <br />Fire Condition MONITOR <br />CORE Fire System MONITOR <br />Building Pressures MONITOR <br />Fans Button(s)MONITOR & CONTROL <br />Lights Button(s)MONITOR & CONTROL <br />Wash Button MONITOR & CONTROL <br />Function <br />Room Temperature MONITOR <br />Duct Temperature(s)MONITOR <br />MUA Discharge Temperature MONITOR <br />Kitchen RTU Discharge Temperature MONITOR <br />Fan Speed MONITOR <br />Fan Amperage MONITOR <br />Fan Power MONITOR <br />VFD Faults MONITOR <br />Controller Faults MONITOR <br />Fan Faults MONITOR <br />Fan Status MONITOR <br />PCU Faults MONITOR <br />PCU Filter Clog Percentages MONITOR <br />Fire Condition MONITOR <br />CORE Fire System MONITOR <br />Building Pressures MONITOR <br />Prep Time Button MONITOR & CONTROL <br />Fans Button MONITOR & CONTROL <br />Lights Button MONITOR & CONTROL <br />Wash Button MONITOR & CONTROL <br />Field Connection Antennas <br />Wired OR Paddle <br />Field Connection to Router <br />OR Ethernet switch <br />Connection for Modbus <br />Factory wired OR Field Wired <br />Terminal Blocks for wired connection <br />Cellular Module <br />Compute module <br />DESCRIPTION OF OPERATION: <br />24 <br />23 <br />22 <br />21 <br />20 <br />19 <br />18 <br />17 <br />16 <br />15 <br />14 <br />13 <br />12 <br />11 <br />10 <br />9 <br />8 <br />7 <br />6 <br />5 <br />4 <br />3 <br />2 <br />1 <br />JOB NO <br />JOB NAME <br />MODEL NUMBER <br />DATE <br />DRAWN BY <br />DWG NO <br />SCHEMATIC TYPE <br />4025056 <br />Joe Serna ES <br />DCV-1111 <br />10/17/2019 <br />INSTALL <br />ECP #1-1 <br />Demand Control Ventilation, w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans modulate based on duct temperature. INVERTER DUTY <br />3 PHASE MOTOR REQUIRED FOR USE WITH VFD. Room temperature sensor shipped loose for field installation.Verify distance between VFD and Motor; additional cost <br />could apply if distance exceeds 50 feet. <br />BREAKER PANEL TO PRIMARY CONTROL PANEL <br />Responsibility: Electrician <br />BREAKER PANEL PRIMARY CONTROL PANEL <br />BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED <br />BREAKER 1PH <br />CONTROL POWER. DO NOT WIRE <br />TO GFCI OR SHUNT TRIP BREAKER. <br />Hot <br />Neutral <br />H1 <br />N1120 V <br />15 A <br />Ground GND <br />1ST HOOD LIGHT BREAKER SHARED W/ CONTROL <br />POWER. SWITCH #1 <br />WIRE TO VFD QUICK CONNECTOR <br />BREAKER 3PH <br />MCA: <br />MOCP: <br />LINE <br />LINE <br />Ground <br />EXH-1 SM-1 <br />GND <br />L1 <br />L2 <br />LINE L3208 V <br />12.8 A <br />30 A <br />BREAKER 3PH <br />WIRE TO VFD QUICK CONNECTOR <br />MCA: <br />MOCP: <br />LINE <br />LINE <br />208 V <br />Ground <br />SUP-2 SM-2 <br />GND <br />L4 <br />L5 <br />LINE L67.6 A <br />15 A <br />CONTROL PANEL TO FANS <br />Responsibility: Electrician <br />PRIMARY PANEL FANS <br />Load Wiring <br />WIRE TO <br />VFD QUICK <br />WIRE TO <br />DISCONNECT <br />CONNECTOR <br />MUST HAVE ITS OWN CONDUIT <br />DO NOT SHARE CONDUIT! <br />FLA: <br />HP: <br />VOLT: <br />EXH-101 <br />LOAD LEG 1 <br />LOAD LEG 2 <br />GND GROUND <br />FAN: <br />SM-1 <br />LOAD LEG 3 <br />U1 <br />V1 <br />W1 <br />10.2 <br />3.000 <br />208 V <br />Load Wiring BLACK <br />BLACK <br />BLACK <br />GREEN <br />WIRE TO <br />VFD QUICK <br />CONNECTOR WHITE <br />RED <br />FLA: <br />HP: <br />VOLT: <br />MUST HAVE ITS OWN CONDUIT <br />DO NOT SHARE CONDUIT! <br />IF VFD MOUNTED IN <br />2ND PANEL, WIRE SF <br />SIGNAL FROM PANEL <br />WITH ECPM03. <br />U2 <br />V2 <br />W2 <br />LOAD LEG 1 <br />LOAD LEG 2 <br />LOAD LEG 3 <br />GND GROUND <br />SUP-202FAN: <br />SM-2 <br />N1 120V NEUTRAL <br />120V HOT <br />N1 <br />6.1 <br />2.000 <br />208 V <br />SF1 <br />MAKE UP AIR <br />PROVING <br />INTERLOCK <br />DAMPER <br />LOW VOLTAGE CONNECTION FOR <br />DAMPER INTERLOCK. WIRE <br />MULTIPLE SUPPLY ON THE SAME <br />ZONE IN SERIES. SHOULD <br />MUA ZONE 1 <br />TERMINAL NAMES <br />DO NOT APPLY <br />IF MUA BY OTHERS <br />ON PCB <br />REMOVE JUMPER <br />HAVE CONTINUITY WHEN DAMPER <br />IS PROVEN OPEN. <br />NOT REQUIRED FOR ALL UNITS. <br />SEE MAKE-UP AIR SCHEMATIC. <br />IL1A <br />IL1B <br />D3 <br />D7 <br />CONTROL PANEL TO ACCESSORY ITEMS <br />Responsibility: Electrician <br />CONTROL PANEL COMPONENT <br />WIRE C1 TO COMMON (1). <br />C1 TO AR1 SHOULD HAVE <br />CONTROL PANEL <br />FIRE SYSTEM <br />TO <br />MICROSWITCH <br />CONTINUITY WHEN ARMED. <br />IF MORE THAN ONE <br />WIRE AR1 TO NORMALLY CLOSED (2). <br />CAP <br />OFF <br />CAP <br />OFF <br />CAP <br />OFFFIRE SYSTEM, WIRE <br />IN SERIES AS SHOWN <br />C1 <br />AR1 <br />MICROSWITCH 1 <br />1:C <br />4:NO <br />2:NC <br />MS-1 <br />1:C <br />4:NO <br />2:NC <br />1:C <br />4:NO <br />2:NC <br />MS-2 <br />C1 <br />AR1 <br />WIRE DIRECTLY TO CONTROL BOARD <br />CAT-5 CONNECTION <br />CONTROL PANEL <br />REMOTE <br />TO <br />MOUNTED <br />SWITCHES <br />PLACE END OF LINE PLUG EOL120AIN EMPTY JACK. PN: EOL120A <br />HMI <br />J4 1 <br />2 <br />CONTROL PANEL <br />HOOD LIGHTS <br />TO <br />1400 W MAX WIRE TO J-BOX ON TOP OF HOOD <br />B1 <br />W1 <br />GND <br />BLACK <br />WHITE <br />GREEN <br />HOOD LIGHTS 1 <br />WIRE DIRECTLY TO COMMUNICATION <br />ROUTERCOMM <br />MODULE. NET REQUIRES 1) DHCP 2) <br />UDP PORT 1444 & 1445 OPEN FOR <br />CAT-5 ETHERNET CONNECTION <br />CONTROL PANEL <br />WORLD WIDE <br />TO <br />WEB <br />OUTBOUND TRAFFIC ONLY. <br /> -- <br />WIRE TO CONTROL BOARD. INSTALL <br />SENSOR IN ROOM AWAY FROM HEAT <br />SOURCES. DO NOT INSTALL SENSOR <br />CONTROL PANEL <br />KITCHEN TEMP <br />TO <br />SENSOR <br />ON THE CEILING GRID, SEE MANUAL. <br />T1A <br />T1B ROOM TEMP <br />FACTORY WIRED TEMPERATURE <br />SENSOR. MOUNTED IN EXHAUST DUCT <br />CONTROL PANEL <br />DUCT SENSOR <br />TO <br />T2A <br />T2B HOOD 1 <br />RISER 1 <br />CAT5 <br />CONTROL PANEL <br />PCUAFM <br />TO <br />J3 <br />J3 <br />DCV TO PCUAFM <br />WASH <br />EF2 I01 <br />C2 H1 <br />AR2 IO4 <br />THE FOLLOWING CONNECTIONS <br />MAY OR MAY NOT BE <br />REQUIRED BASED ON JOBSITE <br />SPECIFICATIONS <br />CONTROL PANEL <br />EXTERNAL <br />SIGNAL FOR <br />SHUNT TRIP <br />ST TERMINAL IS ENERGIZED <br />IN FIRE CONDITION. <br />ST <br />N1 NEUTRAL FROM SHUNT COIL <br />HOT TO SHUNT COIL SHUNT COIL <br />SYSTEM DRY <br />SPARE FIRE <br />CONTACT <br />CONTROL PANEL <br />SPARE CONTACTS WILL MAKE C2 TO <br />AR2 WHEN SYSTEM IS ARMED. THEY <br />ARE USED TO DISABLE EQUIPMENT <br />OR PROVIDE SIGNALS. (NOT FOR <br />BUILDING FIRE ALARM WHICH MUST <br />BE WIRED DIRECTLY TO THE ANSUL <br />ALARM INITIATING SWITCH LOCATED <br />IN ANSUL AUTOMAN) <br />C2 <br />AR2 <br />COMMON <br />NORMALLY OPEN <br />SPARE CONTACTS WILL MAKE <br />CONTROL PANEL <br />ON/OFF WITH <br />DRY CONTACT <br />SUPPLY FAN <br />COMMON TO NORMALLY OPEN <br />WHEN SUPPLY FAN IS ON. <br />GROUP 1 <br />SFC1 <br />SFO1 <br />COMMON <br />NORMALLY OPEN <br />SFC2 <br />SFO2 <br />COMMON <br />NORMALLY OPEN <br />WIRE TO ECPM03 TERMINALS. <br />CONFIGURABLE OUTPUT. <br />DCV SPEED <br />(TOTAL) <br />0-10V OUTPUT <br />ON PCB <br />SEE ECPM03 OWNERS MANUAL. <br />TO BMS <br />+ <br />-VO+ <br />VO- <br />WIRE TO VFD TERMINAL STRIP. <br />PROPORTIONAL TO FREQUENCY. <br />VFD ANALOG <br />(EACH VFD) <br />0-10V OUTPUT <br />IN VFD <br />SEE VFD OWNERS MANUAL. <br />TO BMS <br />+ <br />-30 <br />2 <br />CONTROL PANEL <br />EXTERNAL <br />TO <br />SWITCH <br />SIGNAL SWITCH THROUGH BMS <br />WILL ACTIVATE ZONE1 FANS AND <br />LIGHTS <br />H1 <br />IO1 <br />BMS SWITCH <br />C NO <br />WH <br />BK <br />BK <br />BK <br />BK <br />A B C D E F G H I <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />MOTOR POWER CIRCUIT <br />PANEL LID <br />COMPONENT LIST <br />LABEL DESCRIPTION <br />PN: <br />RA-x <br />34.110.0184.0 <br />120V Relay DPDT <br />PN: <br />ST-X <br />varies <br />Starter <br />PN: <br />OL-X <br />varies <br />Overload <br />PN: <br />C-X <br />varies <br />Contactor <br />PN: <br />TS-x <br />A/CP-PO-T4"-EXPL <br />Duct Thermostat <br />120 VAC <br />RELAY <br />RA-x <br />24 VDC <br />RELAY <br />RD-x <br />PN: <br />PS-1 <br />MDP18-24A-1C <br />Power Sup. 24VDC <br />WH <br />PN: <br />RA-x <br />34.110.0184.0 <br />120V Relay DPDT <br />GR <br />UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. <br />N1 <br />H1 DC-GNDDC+8H1 <br />7PCU <br />6ST <br />5KS <br />4KTS <br />3GAS <br />2AR1 <br />1N1 <br />120VJ9 <br />5OV1 <br />4SF1 <br />3EF1 <br />2B1 <br />1IO1 <br />120VJ7 <br />H12x <br />N12x <br />AR1 <br />GAS <br />ST <br />C1 <br />B1 <br />EF1 <br />SF1 <br />BK IO1 <br />BK <br />BK <br />BK <br />JUMPERW1 <br />BK 14AWG BK <br />64 <br />RD-1 <br />BL PRDC+RO1 <br />PN: <br />RD-x <br />34.110.0188.0 <br />24VDC Light Relay <br />BK WHAR1 N1 <br />BK WHSF178RA-2 <br />7 8RA-1 <br />8 7RD-1 <br />24V <br />1 2 3 4 5 6 7 <br />8 9 10 11 12 13 14 <br />J6 <br />N1 <br />DRY CONTACTS (SHOWN DE-ENERGIZED) <br />ON/OFF WITH <br />FIRE <br />ON/OFF <br />WITH <br />SUP <br />N1RO1 <br />NH <br />FAN <br />PANEL COOLING <br />DRY CONTACTS (SHOWN DE-ENERGIZED) <br />HOOD LIGHTS <br />J3 <br />ECPM03/DAISY CHAIN <br />SM-1 SM-2 <br />ECPM03 <br />J10 IL1AIL1BJUMPER <br />MAKE UP AIR INTERLOCK. <br />1 <br />2 <br />11 <br />1 JUMPER <br />1 <br />2 <br />11 <br />1 JUMPER <br />NOTE: All items on ECPM03 J3 line to be daisy chained <br />from one component to the next, with EOL120A at end <br />of line. Place PN: EOL120A in empty RJ45 port. <br />C <br />RA-2-1 <br />NOSFC1 <br />SFO1 <br />14 AWG <br />YW <br />C <br />RA-2-2 <br />NOSFC2 <br />SFO2 <br />14 AWG <br />YW <br />FACTORY WIRING <br />SCHEMATIC <br />CIRCUIT BOARDS <br />ECPM03 <br />DCV Rev. 2.11.00 <br />HMI Rev. 2.11.00 <br />SC-20 x 18 x 8.62 BOX <br />CONTROL INPUT <br />120V H1=LINE, <br />N1=NEUTRAL, 15A <br />BREAKER. DO NOT <br />CONNECT TO <br />SHUNT TRIP <br />BREAKER. SEE <br />INSTALLATION <br />SCHEMATIC FOR <br />ADDITIONAL REQ. <br />NOTE: IF VFD HAS 1PH 240V INPUT, USE L1 & L2 ONLY. <br />IF VFD HAS 1PH 120V INPUT, USE L1 & N ONLY. <br />LEGEND <br />FIELD WIRING <br />FACTORY WIRING <br />BK- BLACK <br />BL- BLUE <br />BR- BROWN <br />OR- ORANGE <br />WH- WHITE <br />OR/BL- OR/BL STRIPE <br />BL/RD- BL/RD STRIPE <br />RD/GN- RD/GN STRIPE <br />WH/BL- WH/BL STRIPE <br />YW- YELLOW <br />GY- GREY <br />PR- PURPLE <br />RD- RED <br />GR- GREENWH/BLBLH1N1DC-DC+LN <br />-+ <br />PS-01 <br />AC <br />24V <br />GNDDCKSKSBKKS <br />BKEF1 PRWH GR/YWWH/BLBLJ4 J5 <br />NH <br />FAN <br />SECONDARY PANEL COOLING IF NECESSARY <br />EF1 WHBK <br />J1 <br />ECPM03 <br />SCADA <br />WIRED BK <br />RD <br />+-DEST <br />DEST <br />ILB <br />ILC <br />ILA <br />DEST <br />DEST <br />TO ETH <br />CAT-5 <br />PN: <br />SCADA SCADA Module <br />SHD <br />ANT <br />C <br />RA-1-1 <br />C2 <br />TR2 <br />AR2 <br />14 AWG <br />YW <br />DWG NO <br />JOB NO <br />DATE <br />DRAWN BY <br />JOB NAME <br />DESCRIPTION OF OPERATION <br />TYPE <br />DRAWING TITLE <br />4025056 <br />Joe Serna ES <br />FACTORY <br />DCV-1111 <br />10/17/2019 <br />ECP #1-2 <br />Demand Control Ventilation, w/ <br />control for 1 Exhaust Fan, 1 Supply <br />Fan, Exhaust on in Fire, Lights out <br />in Fire, Fans modulate based on <br />duct temperature. INVERTER DUTY <br />3 PHASE MOTOR REQUIRED FOR <br />USE WITH VFD. Room <br />temperature sensor shipped loose <br />for field installation.Verify distance <br />between VFD and Motor; additional <br />cost could apply if distance exceeds <br />50 feet. <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />U/T1 <br />V/T2 <br />W/T3 <br />L1 <br />L2 <br />L3/N <br />GR <br />GR <br />GND <br />VFD: <br />HP: <br />MTR: <br />FLA: <br />P107: <br />P108: <br />P410: <br />P150: <br />P100: <br />P194: <br />P101: <br />P131: <br />P167: <br />P103: <br />P102: <br />L1 <br />L2 <br />L3 <br />14 AWG <br />3 PH <br />30 A <br />208 V <br />U1 <br />V1 <br />W1 <br />SM-1 <br />ESV402N02TXB571 225 <br />01 <br />01 <br />11 <br />61 <br />00 <br />10.2 <br />3.000 <br />EXH-1 <br />N/A <br />N/A <br />60.0 <br />80.0 <br />0.0 <br />GND <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />U/T1 <br />V/T2 <br />W/T3 <br />L1 <br />L2 <br />L3/N <br />GR <br />GR <br />GND <br />VFD: <br />HP: <br />MTR: <br />FLA: <br />P107: <br />P108: <br />P410: <br />P150: <br />P100: <br />P194: <br />P101: <br />P131: <br />P167: <br />P103: <br />P102: <br />L4 <br />L5 <br />L6 <br />14 AWG <br />3 PH <br />15 A <br />208 V <br />U2 <br />V2 <br />W2 <br />SM-2 <br />ESV152N02YXB571 225 <br />01 <br />01 <br />21 <br />87 <br />00 <br />6.1 <br />2.000 <br />SUP-2 <br />N/A <br />N/A <br />60.0 <br />80.0 <br />0.0 <br />GND <br />These products and others are available for <br />demonstration at the Northern CA display center <br /> --For more information or questions Contact-- <br />Captive Aire Systems <br />1110 Burnett Ave, Suite G, Concord, CA 94520 <br />Phone: (925)962-1999, Fax (925)566-8565 <br />Email reg92@captiveaire.com <br />% <br />QC <br />INI <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XX <br />SHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />04/10/2020 <br />REVISIONS BY <br />19-32-050 <br />SLH <br />SLH <br />FILE NO. 39-50 APP NO. 02-118041 <br />KITCHEN RENOVATIONHOUSTON (SERNA) SCHOOLFOODSERVICE EQUIPMENTEXHAUST HOOD PLANFS5.2