My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACAMPO
>
4600
>
1600 - Food Program
>
PR0161846
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2022 4:10:27 PM
Creation date
8/18/2020 9:17:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161846
PE
1632
FACILITY_ID
FA0000244
FACILITY_NAME
LODI USD-HOUSTON SCHOOL
STREET_NUMBER
4600
Direction
E
STREET_NAME
ACAMPO
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
01731001
CURRENT_STATUS
01
SITE_LOCATION
4600 E ACAMPO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire System Information - Job#4025056 <br />1 Ansul R102 3.0/3.0 15 Fire Cabinet Left Left <br />FIRE <br />SYSTEM <br />NO. <br />Tag TYPE SIZE FLOW <br />POINTS <br />INSTALLATION <br />SYSTEM LOCATION ON HOOD <br />Fire System Parts List Key <br />1 <br />0 - 0 - DISC UNION Bursting Disc Union Assembly for Manifold System. <br />0 - 0 - Tank Strap Tank Strap - used for ANSUL Tanks <br />0 - 0 - UCTANKBRACKET Tank Bracket for fire system tank installation in utility cabinets <br />1 - 1 - AT - 3.0 TANK(#1B) - 3.0 Gallon SS Tank (for use with Automan Release, Actuator, <br />or SS Enclosure (UL/ULC)) Macola # 01-429862 <br />3 - 3 - ANS-OEM REGULATED RELEASE - Ansul Regulated Mechanical Release/Bracket Assembly, <br />OEM, R-102, Cartridge Detection Included, Ansul Part # 79493 <br />5 - 5 - LIQ-3.0 AGENT - Ansulex Low PH Wet Chemical Agent, 3 Gallon (UL) 79372 <br />9 - 9 - DT-CART Double Tank Nitrogen Cartridge <br />10 - 10 - TLINK LINK - Test Link (1 test link) Ansul Part # 24916, Macola # 20-24916 <br />11 - 11 - MICRO-SDA MICROSWITCH KIT- Includes 2 switches and Mounting Hardware. Single <br />Dual Electric Switch, One Standard Switch, One Alarm Duty Switch Ansul Part # 437155, <br />Macola # 08-437155 <br />12 - 12 - HOSE HOSE - Rubber Hose <br />27 - 27 - QPSA-1/2 PULLEY SEAL - 1/2" Hood Seal (UL) Ansul Part # 423253, Macola <br /># 32-79768 <br />34 - 34 - RPS-A REMOTE PULL STATION - Red composite (without wire rope) 434618 (Old <br />Macola #06-4835) <br />35 - 35 - PE-LT PULLEY ELBOW - Low Temp. Pulley Elbow, Set Screw Type Ansul Part <br /># 415670, Macola # 11-415671 <br />36 - 36 - PE-HT PULLEY ELBOW - High Temp Pulley Elbow, Compression Type, Ansul Part <br /># 423251, Macola # 10-45771 <br />1 <br />2 <br />2 <br />2 <br />1 <br />0 <br />0 <br />0 <br />1 <br />1 <br />5 <br />1 <br />5 <br />4 <br />0 <br />0 <br />0 <br />0 <br />0 <br />2 <br />1 <br />1 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />FIRE <br />SYSTEM <br />NO. <br />TAG KEY NUMBER - PART DESCRIPTION QTY. BY <br />FACTORY <br />QTY. BY <br />DIST. <br />MANIFOLDED <br />10 11 <br />12 <br />5 9B <br />1B <br />3 <br />1B <br />5 <br />8.5" MAX <br />(MANIFOLDED) <br />28 <br />29 <br />28 <br />30 <br />28 <br />29 <br />28 <br />29 <br />10 1/2" <br />13" <br />13" <br />Hood Front <br />Hood Back <br />28 <br />29 <br />2W Duct1NPlenum 32.0000 32.0000 <br />1FS 1FS 1FS <br />3N 3N <br />12.0000 12.0000 12.0000 23.0000 15.0000 14.0000 120.0000 <br />Hood # 1 Job # 4025056 <br />Model: ND-2-PSP-F Size: 60"x24" Length: 7' 4" <br />24.0000 20.0000 22.5000 21.5000 15.5000 44.5000 38.5000 21.5000 <br />11" <br />14" <br />15" <br />Hood Front <br />Hood Back <br />28 <br />30 <br />2W Duct1NPlenumHood # 2 Job # 4025056 <br />Model: ND-2-PSP-F Size: 60"x24" Length: 10' 0" <br />NOTES <br />- FIELD PIPE DROPS AS SHOWN <br /> SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS <br />- RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, <br /> SALAMANDERS, ETC. <br />- MAXIMUM 9 ELBOWS IN SUPPLY LINE. <br />- IF APPLICABLE, PRE-PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. <br />- FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. <br />- APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE <br /> SIZE, NOT THE OVERALL APPLIANCE SIZE. <br />- THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS <br />Job #: 4025056 <br />Job Name: Joe Serna ES <br />System Size: ANSUL-3.0/3.0-MANIFOLD Total FP required: 15 <br />Hood # 1 7' 4.00" Long x 60" Wide x 24" High <br />Riser # 1 Size: 13" x 13" <br />Hood # 1 Metal Blow-Off Caps included. <br />Hood # 2 10' 0.00" Long x 60" Wide x 24" High <br />Riser # 1 Size: 14" x 15" <br />Hood # 2 Metal Blow-Off Caps included. <br />REMOTE MANUAL PULL STATION <br />MECHANICAL GAS VALVE <br />HIGH TEMP FUSIBLE LINK <br />LOW TEMP FUSIBLE LINK <br />DETECTOR BRACKET <br />DOUBLE MICROSWITCH <br />CARTRIDGE (101-30) <br />CARTRIDGE (101-10) <br />CARTRIDGE (101-20) <br />ANSULEX LIQUID AGENT (1.5 GAL.) <br />ANSULEX LIQUID AGENT (3 GAL.) <br />OEM REGULATED ACTUATOR <br />OEM REGULATED RELEASE <br />3 GALLON TANK <br />1.5 GALLON TANK <br />34 <br />MGV <br />30 <br />29 <br />28 <br />11 <br />9 <br />8 <br />7 <br />6 <br />5 <br />4 <br />3 <br />1B <br />1A <br />LEGEND - FIRE CABINET ANSUL SYSTEM <br />10 TEST LINK <br />260 NOZZLE ASSEMBLY (419341) <br />NOZZLE ASSEMBLY (419339) <br />NOZZLE ASSEMBLY (419343) <br />NOZZLE ASSEMBLY (419340) <br />DUCT NOZZLE (430913) <br />NOZZLE ASSEMBLY (419342) <br />NOZZLE ASSEMBLY (419338) <br />NOZZLE ASSEMBLY (419334) <br />NOZZLE ASSEMBLY (419335) <br />SWIVEL ADAPTOR <br />NOZZLE ASSEMBLY (419336) <br />1/2N <br />2120 <br />230 <br />290 <br />3N <br />245 <br />1W <br />S <br />1N <br />1100 <br />ELECTRICAL GAS VALVEEGV <br />NOZZLE ASSEMBLY (419333)1F <br />12 HOSE ASSEMBLY <br />CARTRIDGE (LT-A-101-30)9A <br />DOUBLE TANK CARTRIDGE9B <br />OEM AUTOMAN RELEASE2 <br />2W DUCT NOZZLE (419337) <br />15 FLOWPOINTS USED ON AN 22 FP <br />UL300 ANSUL R102 6.0 GALLON <br />SYSTEM <br />FIRE SYSTEM NOTES <br />CUSTOMER RESPONSIBLE FOR ADDITIONAL LABOR AND PARTS <br />CHANGES AS A RESULT OF COOKING EQUIPMENT LAYOUT CHANGES OR <br />MISINFORMATION AFTER RELEASE OF ORDER. <br />CUSTOMER RESPONSIBLE FOR ADDITIONAL TRIPS BY FIRE SYSTEM <br />DISTRIBUTOR DUE TO JOB SITE DELAYS. <br />MECHANICAL OR ELECTRICAL GAS VALVE IS TO BE INSTALLED <br />BY PLUMBING CONTRACTOR. PLUMBING PERMIT REQUIRED FOR <br />GAS VALVE INSTALLATION. <br />UNION LABOR CHARGES, IF REQUIRED, ARE EXTRA. <br />REGULATED RELEASE ASSEMBLY, REGULATED ACTUATOR <br />ASSEMBLY, AND TANK ENCLOSURE MUST BE LOCATED <br />IN AREAS WHERE AIR TEMPERATURE WILL NOT FALL <br />BELOW 32 DEGREES F OR EXCEED 130 DEGREES F. <br />SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY <br />C.A.S. OR FIRE DISTRIBUTOR. <br />ALL PIPE FOR 1.5/2.4 GALLON SYSTEM IS 1/4". <br />ALL PIPE FOR 3.0/3.5 GALLON SYSTEM IS 3/8". <br />ALL PIPE SHALL BE BLACK IRON SCHEDULE-40. <br />ALL EXPOSED PIPE SHALL BE CHROME SLEEVED. <br />NOZZLES SHALL BE A MAXIMUM OF 50" ABOVE <br />SURFACE OF COOKING EQUIPMENT. <br />GAS VALVE <br />ELECTRICAL COOKING EQUIPMENT MUST BE SHUT OFF WHEN FIRE <br />SYSTEM IS ACTIVATED. ELECTRICAL CONTRACTOR IS TO PROVIDE <br />ELECTRIC SHUT OFF <br />SHUT OFF CONTACTS OR SHUNT TRIP BREAKERS. THE DESIGN OF <br />THE FIRE SYSTEM SHALL COMPLY WITH S.M.A.C.N.A. GUIDELINES <br />FOR SEISMIC RESTAINTS OF MECHANICAL SYSTEMS. O.S.H.P.D. <br />APPROVED ANCHORAGE R-0010 SUPPORTS AND BRACING OF PIPE <br />& CONDUIT. <br />ANSUL SYSTEM. <br />EXISTING FIRE ALARM SYSTEM MUST BE INTERCONNECTED TO THE <br />IF APPLICABLE TO LOCAL CODE <br />FIRE SUPPRESSION SYSTEM TEST <br />THE TEST WILL BE CONDUCTED IN FRONT OF A SYSTEM INSPECTOR <br />WITH A NITROGEN CARTRIDGE WITH BALLOONS COVERING THE <br />SYSTEM NOZZLES. THE TEST WILL BE CONDUCTED SIMULATING THE <br />REMOTE AND AUTOMATIC ACTUATION. <br />GENERAL <br />PULLS ARE MOUNTED SIDE BY SIDE. THE DISTANCE BETWEEN <br />PROVIDED FOR EACH REMOTE PULL STATION WHEN TWO REMOTE <br />CEILING LINE WITHOUT BENDS OR OFFSETS. ONE 4-0 BOX TO BE <br />FINISHED FLOOR 1/2" EMT. TO BE 12" ABOVE FINISHED DROP <br />THE UPPER RIGHT AND LOWER LEFT OF BOX. TO BE 48" ABOVE <br />4-0 BOX WITH 1/2" KO'S POSITIONED AS SHOWN WITH TABS IN <br />REMOTE PULL STATION <br />CENTERS SHALL BE NO LESS THAN 7". <br />INSTALLATION/PIPING NOTES <br />A. SELECT A RIGID SURFACE FOR MOUNTING THE ENCLOSURE. THE <br />STEPS: <br />ACTUATOR ASSEMBLY REQUIRED BY COMPLETING THE FOLLOWING <br />1. MOUNT THE REGULATED RELEASE ASSEMBLE AND EACH REGULATED <br />MOUNTING LOCATIONS MUST ALLOW THE REGULATED RELEASE <br />ASSEMBLY AND THE REGULATED ACTUATOR ASSEMBLY TO BE WITHIN <br />THE LIMITATION OF THE ACTUATION AND EXPELLANT GAS LINE <br />ASSEMBLY. NOTE: WALL MOUNTED SYSTEMS ONLY. <br />LENGTHS AND MUST BE ABLE TO SUPPORT THE WEIGHT OF THE <br />B. DETACH THE COVER FROM THE ENCLOSURE. REMOVE AGENT TANK <br />FROM ENCLOSURE AND THE EXPELLANT GAS LINE HOSE FROM THE <br />TANK/ADAPTOR ASSEMBLY. <br />C. SECURE ENCLOSURE BOX TO SELECTED MOUNTING LOCATION USING <br />THE FOUR MOUNTING HOLES. USE APPROPRIATE TYPE OF FASTENERS <br />DEPENDING ON THE MOUNTING SURFACE. WALL MOUNTED SYSTEMS. <br />System Designed by <br /> Matt Eidson <br />Ansul Certified Designer <br />Certificate valid until <br />9/04/2019 <br />Flowpoint Chart <br />Nozzle FP QTY TTL FP <br />------------------------------ <br />1N 1 2 2 <br />------------------------------ <br />Total 15FP <br />2W 2 2 4 <br />1FS 1 3 3 <br />3N 3 2 6 <br />34 <br />48" AFF in the <br />path of egress <br />Gas valve size and location <br />per plumbing plans <br />MGV1-1/2 <br />25"-35" <br />30"-40" <br />Duct and Plenum Protection Only <br />These products and others are available for <br />demonstration at the Northern CA display center <br /> --For more information or questions Contact-- <br />Captive Aire Systems <br />1110 Burnett Ave, Suite G, Concord, CA 94520 <br />Phone: (925)962-1999, Fax (925)566-8565 <br />Email reg92@captiveaire.com <br />FIRE SYSTEM - PLAN VIEW <br />SCALE : 3/4" = 1'-0" <br />1 <br />FS5.3 <br />FIRE SYSTEM - ELEVATION VIEW <br />SCALE : 3/4" = 1'-0" <br />2 <br />FS5.3 <br />IMPERIAL <br />PATH OF EGRESS <br />SCALE : 3/4" = 1'-0" <br />3 <br />FS5.3 <br />Pull station 48" AFF <br />in the path of egress <br />path of egress <br />48 24(4) <br />48 24(4) <br />48 24(4) <br />48 24(4) <br />36 24(4) <br />36 24(4)48 24(4)20x2020x20GGGE1E1SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XX <br />SHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />04/10/2020 <br />REVISIONS BY <br />19-32-050 <br />SLH <br />SLH <br />FILE NO. 39-50 APP NO. 02-118041 <br />KITCHEN RENOVATIONHOUSTON (SERNA) SCHOOLFOODSERVICE EXHAUSTHOOD FIRE SYSTEMFS5.3
The URL can be used to link to this page
Your browser does not support the video tag.