My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACAMPO
>
4600
>
1600 - Food Program
>
PR0161846
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2022 4:10:27 PM
Creation date
8/18/2020 9:17:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161846
PE
1632
FACILITY_ID
FA0000244
FACILITY_NAME
LODI USD-HOUSTON SCHOOL
STREET_NUMBER
4600
Direction
E
STREET_NAME
ACAMPO
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
01731001
CURRENT_STATUS
01
SITE_LOCATION
4600 E ACAMPO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACCESS-AT 8" BELOW <br />INTERIOR CEILING LINE. <br />RELIEF PORT Model # 1830 <br />OPENING AND CLOSING. <br />(HEATED VENT) <br />CABLE & VENT <br />J-BOX FOR HEATER <br />ALLOWS EASIER DOOR <br />KASON PRESSURE <br />"EY" SEAL FITTING OR J-BOX <br />J-BOX FOR ELECTRICAL <br />DOOR SECTION <br />CEILING PANEL <br />1/2" RIGID CONDUIT <br />BY ELECTRICIAN <br />PROVIDED BY WALK-IN MANUF. <br />NOTE(S): <br />RIGID CONDUIT AND PENETRATION THRU <br />CEILING PANELS AT JOB SITE. ALL <br />PENETRATIONS PROVIDED BY FSEC CONDUIT BY <br />E.C ALL CONDUITS TO BE SEALED INSIDE AND <br />OUT BY FSEC. <br />"Y" SEAL FITTING OR J-BOX <br />FIXTURE BASE <br />DOOR SECTION OR <br />WALL PANEL <br />CEILING PANEL <br />J-BOX FOR ELECTRICAL <br />ACCESS AT 8" BELOW <br />INTERIOR CEILING PANEL <br />3-WAY PRESS SWITCH AT <br />54" ABOVE FINISHED FLOOR <br />12" RIGID CONDUIT <br />WEATHERPROOF GRAY NEOPRENE <br />RUBBER COVER PLATE WITH CONST. <br />125v BURNING RED NEON PILOT LIGHT <br />VAPOR PROOF FIXTURE Model #1804LG <br />BASE TO BE SURFACE MOUNTED AND <br />INSTALLED AT FACTORY. LEXAN GLOBE <br />AND CFL LAMP TO BE SHIPPED LOOSE <br />WALL CLOSURE ATTACHMENT DETAIL FOR SANITARY PURPOSES NON STRUCTURAL. <br />REMOTE PROBE MOUNTED <br />IN RETURN AIR SYSTEM <br />FROM COIL (TYP.) <br />DRAWN ALUMINUM <br />WITH STAINLESS STEEL <br />FACEPLATE <br />SEALENT BY WALK-IN MANUF. <br />MODULARM <br />Model#75 TEMPERATURE <br />ALARM SYSTEM <br />BUILT IN <br />TRANSFORMER AND <br />N/O & N/C <br />DRY CONTACTS <br />12" RIGID <br />CONDUIT <br />ALARMDISPLAY <br />SAFEALARM <br />RESET <br />DISPLAY <br />RESET TEST <br />TEXT <br />BATTERY <br />MODULARM CORPORATION <br />MODEL 75 TEMPERATURE ALARM <br />WEATHERPROOF GRAY <br />NEOPRENE RUBBER COVER <br />PLATE WITH 125v RED NEON <br />PILOT LIGHT <br />3-WAY PRESS SWITCH <br />AT 45" ABOVE FINISHED <br />FLOOR <br />WALL PANELWALL PANEL N.S.F. CORNER PANEL <br />PLAN VIEW <br />MAX. SPACING OF 40" O.C. <br />SNAP-IN ROSETTE <br />GASKET <br />CAM LOCK CONNECTION @ <br />COVER PLATEJ-BOX <br />CEILING PANEL <br />WALL PANEL <br />1/2" THICK CONDUIT TO <br />STUB-OUT THRU CEILING PANEL <br />2" MIN. AIR SPACE BETWEEN <br />PRE-FAB PANELS AND BLDG. WALLS. <br />NOTE: <br />RIGID CONDUIT AND <br />PENETRATION AT JOB SITE BY <br />ELECTRICAL CONTRACTOR ALL <br />PENETRATIONS MUST BE <br />SEALED BY ELECTRICAL <br />CONTRACTOR. ROOFING SHALL <br />NOT BE PENETRATED. <br />WALL PANEL TO RECESSED PRE-FAB FLOORA THRESHOLD DETAIL FOR FREEZER DOORB THRESHOLD DETAIL FOR REFRIGERATOR DOORC <br />MODULARM CORP. MODEL 75 DETAILJ <br />WALL PANEL AT BUILDING WALLG3 -WAY INTERIOR & EXTERIOR PRESS SWITCHF <br />TYPICAL CAM LOCK CONNECTION DETAILIPRESSURE RELIEF PORT MODEL # 1830 DETAILH <br />SUPPLEMENTAL LATERAL BRACING AT WALK-IN WALL PANEL E <br />EXTERIOR <br />N.S.F. FLOOR PANEL <br />WALK-IN WALL PANEL <br />CAM LOCK CONNECTION <br />@ MAX. SPACING OF <br />23 14" O.C. <br />CONCRETE WITH <br />REINFORCEMENT AND FINISHED <br />FLOOR ( SEE STRUCTURAL <br />DRAWINGS) <br />BUILDING <br />STRUCTURE <br />4" <br />GASKET <br />MINIMUM 2" REQUIRED <br />AIR SPACE BETWEEN <br />WALK-IN AND EXISTING <br />BUILDING STRUCTURE <br />N.S.F. RADIUS <br />GASKET <br />SNAP-IN ROSETTE <br />INTERIOR <br />4"2" <br />GASKET <br />TO BE CAPPED IN <br />CEILING PANELS <br />FACTORY. <br />CAM LOCK <br />CONNECTION @ <br />MAX. SPACING OF <br />23 1/4" O.C. <br />BLDG. CEILING <br />TO REFRIGERATOR WALL <br />SECURE CHANNEL MLDG. <br />WITH TAMPER PROOF SCREWS <br />SILICONE SEALANT <br />NON-REMOVABLE "FORMED" <br />MATCHING MATERIAL <br />WALL PANEL JOINTS <br />JOINTS TO MATCH <br />CLOSURE PANELS OF <br />SILICONE <br />SEALANT <br />CONT. S/S CHANNEL AT TOP <br />TO RECIEVE CLOSURE PANELS <br />WALL PANEL <br />8'-4" <br />WALK-IN <br />CEILING PANEL <br />AT REFRIGERATOR & <br />FREEZER <br />NOTE: BRACING AT WALL <br />PANEL TO CEILING PANEL <br />AND CEILING CLOUSER <br />SNAP-IN ROSETTE <br />GASKET <br />N.S.F. RADIUS <br />CAM LOCK CONNECTION @ MAX. <br />SPACING OF 23 14" O.C. <br />WALL PANEL <br />6" COVE BASE ON EXPOSED AREAS <br />ATTACHED TO WALL PANEL WITH #8x5 8" PAN <br />HD. TEK SCREWS @ 23" O.C. <br />INTERIOREXPOSED EXTERIOR <br />CONCRETE SLAB WITH <br />REINFORCEMENT AND FINISHED <br />FLOOR, REFER TO STRUCTURAL <br />2" <br />4"AT REFRIGERATOR & <br />FREEZER <br />4"2" Min. TO BE FILLED <br />UP WITH GROUT BY G.C. <br />AFTER WALK-IN INSTALLATION <br />N.S.F. FLOOR PANEL <br />WEARING SURFACE. <br />DUAL DOUBLE WIPER <br />(DART TYPE) <br />WEARING SURFACE <br />FLUSH-IN FITTING <br />WALK-IN DOOR <br />2" Min. TO BE FILLED <br />UP WITH GROUT BY G.C., <br /> AFTER WALK-ININSTALLATION <br />STAINLESS STEEL <br />THRESHOLD COVER <br />PLATE <br />N.S.F. FLOOR PANEL <br />4"4"EXTERIOR INTERIOR <br />1 12" X 1 12" X 4" 16ga GALV. STEEL ANGLE <br />ATTACHED TO WALL PANEL WITH 1ea. #12" TEK <br />SCREWS @23" O.C. AND TO CONC. SLAB WITH * HILTI <br />KB-TZ 3/8" Dia. X 2" EMB. OR EQUAL @ 23" O.C. - <br />ANCHOR PRIOR TO INSTALLATION OF WALL PANELS. <br />1/2" <br />1/2" <br />CONCRETE SLAB <br />WITH <br />REINFORCEMENT <br />AND FINISHED <br />FLOOR, REFER TO <br />STRUCTURAL <br />VERIFY <br />CLG. HT <br />2" Min. TO BE FILLED <br />UP WITH GROUT BY G.C., <br /> AFTER WALK-INSTALLATION <br />SNAP-IN <br />ROSETTE <br />STUB-OUT THRU CEILING PANEL <br />1/2" THICK CONDUIT TO <br />1. <br />2. <br />PROVIDED BY WALK-IN MANUF. <br />NOTE(S): <br />1. <br />2. <br />PROVIDED BY WALK-IN MANUF. <br />NOTE(S): <br />1. <br />2. <br />PROVIDED BY WALK-IN MANUF. <br />NOTE(S): <br />1. <br />LATERAL BRACING PER <br />STRUCTURAL DRAWINGS <br />REFER TO DETAIL A/FS6.1 <br />FOR ANCHORAGE REQ. <br />REFER TO DETAIL A/FS6.1 <br />FOR ANCHORAGE REQ. <br />RIGID CONDUIT AND PENETRATION THRU <br />CEILING PANELS AT JOB SITE. ALL <br />PENETRATIONS PROVIDED BY FSEC CONDUIT BY <br />E.C ALL CONDUITS TO BE SEALED INSIDE AND <br />OUT BY FSEC. <br />HEATER CHANNEL WITH <br />HEATER WIRE ON <br />FREEZER DOOR ONLY <br />DUAL DOUBLE WIPER <br />(DART TYPE) <br />CONCRETE SLAB WITH <br />REINFORCEMENT AND FINISHED <br />FLOOR <br />N.S.F. FLOOR PANEL <br />FLUSH-IN FITTING <br />WALK-IN DOOR <br />EXTERIOR <br />STAINLESS STEEL <br />THRESHOLD <br />COVER PLATE <br />1/4" MAX4"4" <br />INTERIOR <br />* NOTE: INSTALL ANCHOR PER ICC-ES <br />ESR-1917. TORQUE TEST =25 FT.LB <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XX <br />SHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />04/10/2020 <br />REVISIONS BY <br />19-32-050 <br />SLH <br />SLH <br />FILE NO. 39-50 APP NO. 02-118041 <br />KITCHEN RENOVATIONHOUSTON (SERNA) SCHOOLFOODSERVICE EQUIPMENTWALK-IN REFRIG. DETAILSFS6.1
The URL can be used to link to this page
Your browser does not support the video tag.