My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2526
>
2200 - Hazardous Waste Program
>
PR0514248
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2020 4:29:23 PM
Creation date
8/18/2020 11:10:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0514248
PE
2294
FACILITY_ID
FA0010245
FACILITY_NAME
DTE STOCKTON LLC
STREET_NUMBER
2526
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503009
CURRENT_STATUS
01
SITE_LOCATION
2526 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IV. CERTIFICATION <br /> DTE Stockton <br /> Used Oil Tank System <br /> December 2o18 <br /> 22 CCR 66265192 requires owners of a new hazardous waste tank system to ensure that the - <br /> tank system is adequately designed and constructed,and to obtain and keep on file at the <br /> Facility,a written assessment,reviewed and certified by an independent,qualified,professional <br /> engineer,registered in California,that attests to the tank system's integrity. <br /> The preceding written assessment has determined that the tank system is adequately designed <br /> and has sufficient structural strength and compatibility with the waste(s)to be transferred, <br /> stored or treated to ensure that it will not collapse, rupture,or fail. The assessment for an <br /> above-ground system considered the following: l)design standard(s)according to which the <br /> tank and ancillary equipment have been constructed; 2)hazardous characteristics of the <br /> waste(s)to be handled; and 3)foundation and seismic anchorage design. - <br /> The tank system was inspected on December 5,2018. The visual inspection found none of the <br /> following to be in evidence for the primary tank:weld breaks,punctures,scrapes of protective <br /> coatings,cracks,corrosion,structural damage or installation defects. <br /> As required by 22 CCR 66265.192(k)(n),based on the findings of this assessment,I estimate <br /> that the new tank system has at least ten(1o)years of service life under current conditions. In <br /> accordance with 22 CCR 66265.192(h)(1),this assessment is valid for a maximum period of five <br /> (5)years and the tank system should be re-assessed at that time to obtain a new estimate of <br /> remaining service life. <br /> Based on my assessment of the tank system, I can attest that the tank system has <br /> sufficient structural integrity,is acceptable for transferring,storing and treating <br /> the intended hazardous waste, and is suitably designed to achieve the <br /> requirements under zz CCR 66z65.192. <br /> lrertlfy,under penalty oflaw that this document and allattachments wereprepared under my direction orsuperuision in <br /> accordance with a system designed to assure that qualylodpersonne/properly gatherand valuate the informationsubmitted. <br /> Based on my inquiry ofthe person or persons who manage the system,or thosepersonsdimetly mspmuibleforgathering the <br /> information,the information submitted is,to he the best ofmy knowledge and belief,true,accurate,andcomplete.lam aware <br /> thatthere are significantpenaltiesfor submitting false information,including thepossibility offuw and imprisonmentfor <br /> knowing oialatians. <br /> 1 QROFESS/0 <br /> k Nd,529$6 <br /> Go A-314. 2 -'(. /- 1-9 <br /> Stephen V. Huvane,P.E. 41Date <br /> Civil(CA)NO.52385 '� civic <br /> 9�OP CAl1I_0 <br /> 4 TRC <br /> neeul6 you can rely on <br />