My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUPONT
>
1351
>
4800 – General/Other Program
>
PR0528782
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 5:11:44 PM
Creation date
8/19/2020 4:45:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4800 – General/Other Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0528782
PE
1863
FACILITY_ID
FA0016553
FACILITY_NAME
DREYERS GRAND ICE CREAM
STREET_NUMBER
1351
STREET_NAME
DUPONT
STREET_TYPE
CT
City
MANTECA
Zip
95336-6004
APN
22121019
CURRENT_STATUS
01
SITE_LOCATION
1351 DUPONT CT
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
External Events Analysis PHA Lead By: C'Anna Lundberg,Resource Compliance <br /> Dreyer's Grand Ice Cream Date: 7/29/2020 <br /> Ammonia Refrigeration System <br /> Potential to The Expected Date of Monitoring <br /> DetectionType of Create a Completion of any Changes Major Hazards Process Mitigatio,n and External Magnitude or Scope of External Events Which Were Considered Resulting From the Most Controls in Systems in Since the <br /> Event Release? Recent Hazard Review or Identified Use Use Systems in Last PHA <br /> (Yes/No) PHA Use <br /> 2745.6(1)(1) 2745.6(1)(2) 2745.6(1)(3) 2745.6(e)(1) 2745.6(e)(2) 2745.6(e)(3) 2745.6(e)(4) 2745.6(e)(5) 2745.6(e)(6) <br /> 2745.7(q)(1) 2745.7(q)(2) 2745.7 3 2745.7(e)(1) 2745.7 e 2 2745.7 e 3 2745.7 e 4 2745.7 e 5 2745.7 e 6 <br /> Is equipment adequately protected from damage Yes-Visual inspection reveals that th <br /> due to movement of process equipment as a building/equipment located outside is inYes N/A <br /> result of high winds? structural condition. <br /> Yes-The likelihood of wind-borne debris <br /> Is equipment adequately protected from damage impacting the system is low.High winds are Yes N/A Automatic Shut- <br /> from impact of wind-borne debris? Offs,Computer <br /> a i <br /> this i <br /> l <br /> lik <br /> unev n s regon. <br /> c Toxic Release, Control Machinery Ammonia <br /> Is equipment adequately protected from <br /> Yes-Structures appear to be adequate.High Equipment Systems, Room Detection None <br /> neighboring structures that might be damaged Yes N/A <br /> winds are unlikely in this region. Failure Manual Shut- (enclosure) System <br /> from high winds? <br /> Yes-Location of equipment does not require Offs,Check <br /> outdoor elevated work.The only exception is Valves <br /> Are procedures in place to restrict elevated work the roof of the building,but most equipment is No N/A <br /> when winds exceed 25 mph? located away from the edge of the roof.High <br /> winds are unlikelv in this re ion. <br /> y Yes-The likelihood of lightning striking <br /> J Is equipment adequately protected from damage ammonia equipment is low.Lightning storms Yes N/A <br /> from lightning? <br /> are unlikelV in this region. <br /> 3 Yes-The likelihood of lightning striking <br /> 0Are personnel adequately protected from injury <br /> 3 from lightning? personnel is low.Lightning storms are unlikely No N/A Automatic Shut- <br /> in this reqion. Offs,Computer <br /> Toxic Release, <br /> Yes-The likelihood of lightning striking utilities Control Machinery Ammonia <br /> Are utilities adequately protected from lightning is low.Lightning storms are unlikely in this Yes N/A Equipment Systems, Room Detection None <br /> M or static electricity? Failure, <br /> region. Manual Shut- (enclosure) System <br /> Explosion,Fire <br /> m Are procedures in place for bonding and Offs,Check <br /> grounding material transfers to protect against Yes-Lockout/tagout program is in place to Yes NIA Valves <br /> °c' static energy accumulation and discharge? control electrical energy. <br /> c <br /> 1 Are procedures in place to manage a partial or <br /> Yes-Loss of power occurs occasionally and <br /> complete loss of power and other utilities? facility adapts accordingly.SOP is in place for Yes N/A <br /> a start-up following a shut-down. <br /> 2 <br /> Doc ID: 6a6ea4fac281501 cd30efa4128b75fd8a1870d1 a <br />
The URL can be used to link to this page
Your browser does not support the video tag.