My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUPONT
>
1351
>
4800 – General/Other Program
>
PR0528782
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 5:11:44 PM
Creation date
8/19/2020 4:45:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4800 – General/Other Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0528782
PE
1863
FACILITY_ID
FA0016553
FACILITY_NAME
DREYERS GRAND ICE CREAM
STREET_NUMBER
1351
STREET_NAME
DUPONT
STREET_TYPE
CT
City
MANTECA
Zip
95336-6004
APN
22121019
CURRENT_STATUS
01
SITE_LOCATION
1351 DUPONT CT
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
External Events Analysis PHA Lead By: C'Anna Lundberg,Resource Compliance <br /> Dreyer's Grand Ice Cream Date: 7/29/2020 <br /> Ammonia Refrigeration System <br /> Potential to The Expected Date of Monitoring <br /> DetectionType of Create a Completion of any Changes Major Hazards Process Mitigatio,n and External Magnitude or Scope of External Events Which Were Considered Resulting From the Most Controls in Systems in Since the <br /> Event Release? Recent Hazard Review or Identified Use Use Systems in Last PHA <br /> (Yes/No) PHA Use <br /> 2745.6(1)(1) 2745.6(1)(2) 2745.6(1)(3) 2745.6(e)(1) 2745.6(e)(2) 2745.6(e)(3) 2745.6(e)(4) 2745.6(e)(5) 2745.6(e)(6) <br /> 2745.7(g)(1) 2745.7r(2) 2745.7 3 2745.7 e 1 2745.7 e 2 2745.7 e 3 2745.7 e 4 2745.7 e 5 2745.7 e 6isual inspection reveals that theIs equipment adequately protected to prevent anery room piping is not sufficiently <br /> hazardous materials release due to building rted with rigid pipe supports and seismicYes 7/31/2021 <br /> damage as a result of seismic activity? g.Dreyer's Grand Ice Cream is in the <br /> s of correcting this and\has hired CaICA <br /> all seismic bracing. <br /> Is equipment adequately protected to prevent a Yes-Select areas of deficient pipe supports is <br /> hazardous materials release due to piping summarized in the 2020 Mechanical integrity Yes N/A <br /> support failure as a result of seismic activity? and Code Compliance Report. Automatic Shut- <br /> Are personnel adequately protected to prevent Yes-Emergency Response Program is being Offs,Computer <br /> injury from a hazardous materials release as a implemented and employees receive sufficient No N/A Toxic Release, Control Machinery Ammonia <br /> r result of seismic activity? training. Equipment Systems, Room Detection None <br /> Lu Are personnel adequately protected to prevent Yes-Emergency Response Program is being Failure Manual Shut- (enclosure) System <br /> injury from seismic activity? implemented and employees receive sufficient No N/A Offs,Check <br /> training. Valves <br /> Yes-The Seismic Revalidation of the Existing <br /> Have the results of all seismic analyses been Ammonia Refrigeration System was performed N/A N/A <br /> documented to support the above answers? by Kellie Jones,P.E..See report dated <br /> 01/29/16. <br /> The buildings were designed in accordance <br /> Which edition of the building code was used with the 2000 version of the Uniform Building <br /> when the process was designed? Code and the 2001 California Building Code. N/A N/A <br /> 1 <br /> Doc ID: 6a6ea4fac281501cd30efa4128b75fd8a1870d1a <br />
The URL can be used to link to this page
Your browser does not support the video tag.