My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUPONT
>
1351
>
4800 – General/Other Program
>
PR0528782
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 5:11:44 PM
Creation date
8/19/2020 4:45:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4800 – General/Other Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0528782
PE
1863
FACILITY_ID
FA0016553
FACILITY_NAME
DREYERS GRAND ICE CREAM
STREET_NUMBER
1351
STREET_NAME
DUPONT
STREET_TYPE
CT
City
MANTECA
Zip
95336-6004
APN
22121019
CURRENT_STATUS
01
SITE_LOCATION
1351 DUPONT CT
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
External Events Analysis PHA Lead By: C'Anna Lundberg,Resource Compliance <br /> Dreyer's Grand Ice Cream Date: 7/29/2020 <br /> Ammonia Refrigeration System <br /> Potential to The Expected Date of Monitoring <br /> DetectionType of Create a Completion of any Changes Major Hazards Process Mitigatio,n and External Magnitude or Scope of External Events Which Were Considered Resulting From the Most Controls in Systems in Since the <br /> Event Release? Recent Hazard Review or Identified Use Use Systems in Last PHA <br /> (Yes/No) PHA Use <br /> 2745.6(1)(1) 2745.6(1)(2) 2745.6(1)(3) 2745.6(e)(1) 2745.6(e)(2) 2745.6(e)(3) 2745.6(e)(4) 2745.6(e)(5) 2745.6(e)(6) <br /> 2745.7(q)(1) 2745.7 q 2 2745.7 3 2745.7 e 1 2745.7 e 2 2745.7 e 3 2745.7 e 4 2745.7 e 5 2745.7 e 6 <br /> Is equipment adequately protected from al inspection reveals that process Automatic Shut- <br /> equipment is not located in areas subject to Yes N/A <br /> vehicular impacts? Offs,Computer <br /> n vehicular traffic and/or is adequately protected. Control <br /> E Toxic Release, Machinery Ammonia <br /> Yes-ore <br /> Grand Ice Cream has safe Systems, <br /> m Are procedures/practices in place to manage Equipment Room Detection None <br /> vehicular movement e. cranes,trains, practices in place for forklift movement in the Failure Manual Shut- <br /> ( g., (enclosure) System <br /> dock which contains refrigeration equipment. Offs,Check <br /> 0 vehicles)in process areas during all hours of the Pallets are not stacked on top of each other in Yes N/A Valves,Relief <br /> > day/night including in normal and inclement <br /> weather? the dock which makes it very unlikely that Valves <br /> eva orators will be im acted by forklifts. <br /> Is equipment adequately protected from extreme Yes-The refrigeration systems were designed Automatic Shut- <br /> E <br /> by refrigeration contactors to account for high Yes N/A <br /> @ ambient high/low temperatures? ambient temperatures. Toxic Release, Offs,Computer <br /> IDEquipment Control Machinery Ammonia <br /> c Is equipment adequately protected from flooding Flooding is unlikely in this region. No N/A Failure, Systems, Room Detection None <br /> from internal as well as externals sources? Overpressuriza Manual Shut- <br /> (enclosure) System <br /> E Offs,Check <br /> Z Are procedures/practices in place for removing tion <br /> rainwater from secondary containment areas in a No areas identified requiring rainwater No N/A Valves,Relief <br /> timet manner and are the adequate? removal. Valves <br /> Are measures in place to minimize impacts to Yes-Most refrigeration equipment is located Automatic Shut- <br /> process equipment due to a disgruntled inside the machinery room or directly outside Yes N/A Offs,Computer <br /> 0employee? the machinery room. Control <br /> mSystems, Machinery Ammonia <br /> Toxic Release Room Detection None <br /> CD Has a Security Vulnerability Assessment(SVA) No-Security Vulnerability Assessment(SVA) Manual Shut- <br /> (enclosure) System <br /> been performed to evaluate potential impacts to is not required by DHS for ammonia No N/A Offs,Check <br /> process equipment? refrigeration processes. Valves,Relief <br /> Valves <br /> 5 <br /> Doc ID: 6a6ea4fac281501 cd30efa4128b75fd8a1870d1 a <br />
The URL can be used to link to this page
Your browser does not support the video tag.