My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUTO PLAZA
>
2830
>
2200 - Hazardous Waste Program
>
PR0537747
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 1:34:29 PM
Creation date
8/25/2020 10:03:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0537747
PE
2220
FACILITY_ID
FA0017746
FACILITY_NAME
CALIBER COLLISION CENTER
STREET_NUMBER
2830
STREET_NAME
AUTO PLAZA
STREET_TYPE
WAY
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
2830 AUTO PLAZA WAY STE 110
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Cooks Collision of Tracy 2830 Auto Plaza Way,Tracy October 24, 2014 <br /> Universal Waste <br /> 709 HSC 25201.16(g) Failed to store used aerosol cans in an accumulation container o V o R o COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing o V o R o COS <br /> 711 HSC 25201.160) Failed to submit or amend notification for aerosol can processing o V o R o COS <br /> 712 CCR 66273.34 Failed to label universal waste to identify type of universal waste o V ❑R c COS <br /> 713 CCR 66273.35 Stored UW onsite greater than one year or was unable to demonstrate the time UW has been stored o V o R o COS <br /> 714 CCR 66273.36 Failed to train employees and maintain records on UW handling and emergency procedures o V o R o COS <br /> 715 CCR 66273.39 Failed to keep complete records of each shipment of universal waste for three years o V o R o COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation o V o R c COS <br /> 3020 See below Unlisted Training violation o V o R o COS <br /> 3030 See below Unlisted Operations/Maintenance violation o V ❑R o COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation o V o R o COS <br /> 3050 See below Unlisted Abandonment/I[leg a]Disposal/Unauthorized Treatment violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 66262.11, 66262.40(c) Failed to determine if a waste is a hazardous waste or retain waste analysis on site for 3 <br /> years. <br /> No waste analysis was available for leftover paint waste in plastic containers from the spray guns. This waste is being <br /> disposed of as non-hazardous waste. A generator shall make a hazardous waste determination and keep a record of <br /> any test results,waste analyses, or other determinations made in accordance with hazardous waste regulations for at <br /> least three years from the date that the waste was last disposed of. Immediately locate a copy of the waste analysis <br /> conducted for the leftover paint waste and submit a copy to the EHD. If a copy is unavailable, immediately make a <br /> hazardous waste determination and begin managing the leftover paint waste under Title 22 hazardous waste <br /> regulations. This is a repeat violation, Class Il. <br /> 103 CCR 66262.34(d)(2) No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following information <br /> must be posted by a phone:the name and phone number of the emergency coordinator; location of fire extinguishers, <br /> spill control equipment, and if present, fire alarm; and the phone number of the fire department, unless the facility has a <br /> direct alarm. Immediately appoint an emergency coordinator and post the required information by a phone. A form is <br /> provided that can be used for this purpose. Class II Violation. <br /> Received by(initial): Inspector: .Phone: Date: <br /> MICHELLE HENRY, Senior REHS (209)468-3454 10/24/2014 <br /> Page 3 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.