My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 4:36:01 PM
Creation date
8/25/2020 11:10:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEI/RM 200 - 17 <br /> APPENDIX <br /> WDROSTATIC TEST IMETHOD <br /> SINGLIEo I DO1 VACUUM TESTMETHOD <br /> Facility Name: Owner: <br /> Address: Address: <br /> City, State, Zip Code: City, State, Zip Code: <br /> Facility I.D. #: Phone #: <br /> Testing Company: Phone #: Date: <br /> This procedure is to test the leak integrity of single- and double-walled spill buckets. See PEVRP1200 Section 6 . 2 for hydrostatic test <br /> method, Section 6.3 for single-walled vacuum test method and Section 6.4 for double-walled vacuum test method. <br /> Tank Number <br /> Product Stored <br /> Spill Bucket <br /> Capacity <br /> Manufacturer <br /> Construction ❑ Single-walled ❑ Single-walled ❑ Single-walled ❑ Single-walled ❑ Single-walled ❑ Single-walled <br /> ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled <br /> Test Type ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic <br /> ❑ Vacuum ❑ Vacuum ❑ Vacuum ❑ Vacuum ❑ Vacuum ❑ Vacuum <br /> ❑ Single-walled ❑ Single-walled ❑ Single-walled El Single-walled ❑ Single-walled ❑ Single-walled <br /> ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled <br /> Spill Bucket Type ❑ Product ❑ Product ❑ Product ❑ Product ❑ Product ❑ Product <br /> ❑ Vapor ❑ Vapor ❑ Vapor ❑ Vapor ❑ Vapor ❑ Vapor <br /> Liquid and debris <br /> removed from ❑ Yes ❑ No [] Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> spill bucket? * <br /> Visual Inspection <br /> (No cracks, loose <br /> parts or separa- ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass Cl Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> tion of the bucket <br /> from the fill pipe.) <br /> Tank riser cap ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes [] No <br /> included in test? ❑ NA ❑ NA ❑ NA ❑ NA ❑ NA ❑ NA <br /> Drain valve ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> included in test? ❑ NA ❑ NA ❑ NA ❑ NA ❑ NA ❑ NA <br /> Starting Level <br /> Test Start Time <br /> Ending Level <br /> Test End Time <br /> Test Period <br /> Level Change <br /> Pass/fail criteria: Must pass visual inspection . Hydrostatic: Water level drop of less than 1/8 inch; Vacuum single-walled only: <br /> Maintain at least 26 inches water column; Vacuum double-walled : maintain at least 12 inches water column . <br /> Test Results 11 Pass 11 Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail 11Pass 11Fail ❑ Pass ❑ Fail 13Pass El Fall <br /> Comments: <br /> *All liquids and debris must be disposed of properly. <br /> Tester's Name (print) Tester's Signature <br /> pel .org <br /> f <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.