My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 4:36:01 PM
Creation date
8/25/2020 11:10:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEVRP1200 - 17 <br /> USTOVERFILL EQUIPMENTiNSPECTION <br /> AUTOMATIC + DEVICE AND BALL FLOAT <br /> Facility Name: Owner: <br /> Address : Address: "! <br /> City, State, Zip Code : City, State , Zip Code: <br /> Facility I .D. #: Phone #: <br /> Testing Company: Phone #: Date: <br /> This data sheet is for inspecting automatic shutoff devices and ball float valves. See PEVRP1200 Section 7 for inspection procedures. <br /> Product Grade <br /> Tank Number . <br /> Tank Volume, gallons <br /> Tank Diameter, inches <br /> Overfill Prevention Device Brand <br /> Type ❑ Automatic ❑ Automatic ❑ Automatic ❑ Automatic ❑ Automatic ❑ Automatic <br /> Shutoff Device Shutoff Device Shutoff Device Shutoff Device Shutoff Device Shutoff Device <br /> ❑ Ball Float ❑ Ball Float ❑ Ball Float ❑ Ball Float ❑ Ball Float ❑ Ball Float <br /> Valve Valve Valve Valve Valve Valve <br /> AUTOMATIC SHUTOFF DEVICE INSPECTION <br /> 1. Drop tube removed from tank? ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> 2. Drop tube and float mecha- ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> nisms free of debris? <br /> 3. Float moves freely without <br /> binding and poppet moves into ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> flow path? <br /> 4. Bypass valve in the drop tube ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No [] Yes ❑ No <br /> open and free of blockage (if ❑ Not Present ❑ Not Present ❑ Not Present ❑ Not Present ❑ Not Present ❑ Not Present <br /> present)? <br /> 5. Flapper adjusted to shut off ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> flow at 95% capacity? * <br /> A "No" to any item in Lines 1-5 indicates a test failure. <br /> BALL FLOAT VALVE INSPECTION * * <br /> 1. Tank top fittings vapor- tight ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> and leakfree? <br /> 2. Ball float cage free of debris? ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> 3 . Ball free of holes and cracks ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> and moves freely in cage? <br /> 4.Vent hole in pipe open and ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> near top of tank? <br /> 5 . Ball float pipe proper <br /> length to restrict flow at 90% ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> capacity? * * * <br /> A "No" to any item in Lines 1-5 indicates a test failure. <br /> Test Results ❑ Pass ❑ Fall ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail TEI Pass ❑ Fail <br /> Comments: <br /> * Use manufacturer's suggested procedure for determining if automatic shutoff device will shut off flow at 95 % capacity. <br /> ** If a ball float is found to fail the inspection , another method of overfill must be used. <br /> * * * Use manufacturer's suggested procedure for determining if flow restriction device will restrict flow at 90% capacity. <br /> Tester's Name ( print) Tester's Signature <br /> pei .org <br />