My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 4:30:09 PM
Creation date
8/25/2020 2:28:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB , January 2002 Page 1 of 1 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: r Tank Manufacturer I+` Industry Standard r Professional Engineer <br /> r Other (Specify) <br /> Test Method Used By: r Pressure f* Vacuum r Hydrostatic <br /> r Other (Specify) <br /> Test Equipment Used : 5iu a Equipment Resolution: :20 <br /> Tank# tl Tank# T-2 Tank# T-3 Tank# t4 <br /> Is Tank Exempt From Testing?' r Yes r No r Yes t*' No r Yes r No C Yes G No <br /> Tank Capacity: 9684 9684 9684 9684 <br /> Tank Material: Fiberglass Fiberglass Fiberglass <br /> Tank Manufacturer unknown unknown unknown unknown <br /> Product Stored: REG UNLEAD REGULAR REGULAR SUPREME <br /> Wait time between applying pressure/vacuurMvater and starting 15 min 15 min 15 min 15 min <br /> test <br /> Test Start Time: 11 : 32: 00 11 : 32: 00 13 : 12 : 00 13 : 12 : 00 <br /> Initial Reading (RI): 10 . 00000 in . HG 10 . 00000 in . HG 10 . 00000 in . HG 10 . 00000 in . HG <br /> Test End Time: 12: 32: 00 12 : 32: 00 14 : 12 : 00 14 : 12 : 00 <br /> Final Reading (RF): 10 . 00000 in . HG 10 . 00000 in . HG 10 . 00000 in . HG 10 . 00000 in . HG <br /> Test Duration: 1 hr 1 hr 1 hr 1 hr <br /> Change in Reading (RF-RI) : 0 . 00000 in . HG 0 . 00000 in . HG 0 . 00000 in . HG 0 . 00000 in . HG <br /> Pass/Fail Threshold or Criteria: +/- 0 . 00000 +/- 0 . 00000 +/- 0 , 00000 +/- 0 . 00000 <br /> Test Result: Pass Pass Pass Pass <br /> Was sensor removed for testing? r Yes r Nor NA r Yes r+ Nor NA r Yes t* Nor NA r Yes r* Nor NA <br /> Was sensor properly replaced and verified functional after testing? r Yes r Nor* NA r Yes r No 6NA Yes No �* NA Yes r Nor* NA <br /> Comments (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, such as systems <br /> that are hydrostatically monitored or under constant vacuum , are exempt from periodic containment testing . <br />
The URL can be used to link to this page
Your browser does not support the video tag.