My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 4:30:09 PM
Creation date
8/25/2020 2:28:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 2 of 2 <br /> 5 . SECONDARY PIPE TESTING <br /> Test Method Developed By : Piping Manufacturer ' Industry Standard F; Professional Engineer <br /> Other (Specify) <br /> Test Method Used By : Wo Pressure Vacuum Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used : gauge Equipment Resolution : .20 <br /> (Tank t4 - SUPREME) <br /> STP Containment 1 to <br /> 1/23 3/4, 5/65 7/8 <br /> Piping Material : dw fiberglass <br /> Piping Manufacturer : smith <br /> Piping Diameter: 3 in. in, in. in. <br /> Length of Piping Run : 200 ft <br /> Product Stored: SUPREME <br /> Method and location of <br /> sump <br /> piping-run isolation : <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min min min min <br /> starting test : <br /> Test Start Time: 11 :05 :00 <br /> Initial Reading (RI): 5 .00000 PSI <br /> Test End Time : 12 :05 :00 <br /> Final Reading (RF): 5 .00000 PSI <br /> Test Duration: I hr <br /> Change in Reading (RF-RI): 0.00000 PSI <br /> Pass/Fail Threshold or +/- 0.00000 +/- <br /> Criteria: <br /> Test Result : Pass <br /> Comments - (include information on repairs made prior to testing, and recovnnended follow-zip for failed tests) <br /> t <br /> WO : 2339260 <br />