Laserfiche WebLink
N GENERAL NOTES - GUEST ROOMS <br /> � U <br /> A. ALL ELECTRICAL DEVICES(LIGHT FIXTURES, LIGHT SWITCHES, EXHAUST FANS, , w <br /> DATNTELEPHONE JACKS,SMOKE DETECTORS, HORN STROBES, ETC)ARE SHOWN ON THE ARCHITECTURAL SHEETS. <br /> B. SEE NOTES BELOW FOR ADDITIONAL INFORMATION. SEE ALSO ELECTRICAL LIGHT <br /> FIXTURE SCHEDULE AND PANEL SCHEDULES ON THE E6 SERIES SHEETS FOR <br /> O N ADDITIONAL INFORMATION ON LIGHT FIXTURES AND CIRCUITING. REFER TO <br /> U <br /> ARCHITECTURAL DRAWINGS, DETAILS,AND ELEVATIONS FOR FINAL LOCATIONS, <br /> M v MOUNTING HEIGHTS,AND FINISHES REQUIRED FOR ELECTRICAL DEVICES PRIOR TO <br /> ROUGH-IN. <br /> o C. FOR ALL GUEST ROOMS PROVIDE TAMPER-RESISTANT RECEPTACLE UNITS IN <br /> ACCORDANCE WITH CEC 210.52,ALL 125-VOLT, 15-AND 20-AMPERE RECEPTACLES RED INC ARCHITECTS <br /> SHALL BE LISTED TAMPER RESISTANT RECEPTACLES.THIS INCLUDE DUPLEXES, 1217 J STREET,MODESTO,CA 95354 <br /> GFCIs,SINGLE RECEPTACLES,AND FLOOR BOXES. RECEPTACLES, EVEN IF 209.522.8900 <br /> DEDICATED TO A SPECIFIC USE AND NOT READILY ACCESSIBLE, MUST BE TAMPER- <br /> RESISTANT. SEAL: <br /> D. FOR ALL GUEST ROOMS LIVING AND SLEEPING AREAS, PROVIDE ARC-FAULT <br /> CIRCUIT PROTECTION PER CEC 210.12. <br /> E. NM CABLE('ROMEX')IS ALLOWED FOR GUEST ROOMS AND CORRIDORS, ENT <br /> ('SMURF TUBE') IS NOT ALLOWED FOR BRANCH CIRCUITING. USE OF NM('ROMEX') <br /> SUBJECT TO FRANCHISE AND LOCAL JURISDICTION APPROVAL. EC RESPONSIBLE eR SION <br /> FOR OBTAINING APPROVAL. �pNN J.Cpq F� <br /> F. PROVIDE DEDICATED NEUTRAL(GROUNDED)CONDUCTOR FOR ALL BRANCH �� a <br /> CIRCUITS. NO MULTI-WIRE BRANCH CIRCUITS ARE ALLOWED. ^ <br /> G. INSTALL RECEPTACLES IN ACCORDANCE WITH PART 3 OF CEC ARTICLE 210 AS WELL cr No. E 21841 <br /> AS ALL STATE AND LOCAL BE <br /> COORDINATED WITH RCHITE TURALDRAW NGS ANNDES. FIAL OUTLETATIONS ELEEVAT EONS AS WELL AS ALL * P:03/31/2019 <br /> CURRENT SPRINGHILL BY MARRIOTT DESIGN STANDARDS. sTgT T oe��* <br /> m H. WITHIN EACH GUEST ROOM, DO NOT INSTALL OUTLET BOXES FOR ELECTRICAL F OF CA�\F <br /> cu <br /> D DEVICES BACK-TO-BACK IN THE SAME STUD CAVITY. OUTLET BOXES SHALL BE <br /> 004/15/2019 <br /> In OFFSET HORIZONTALLY A MINIMUM OF 4"FOR ADJACENT ROOMS OR HAVE ONE <br /> STUD OF SEPARATION. ELECTRICAL BOXES LOCATED IN THE SAME STUD CAVITY OR <br /> LESS THAN 24"APART WITHIN A RATED ASSEMBLY SHALL BE SEPARATED BY FIRE <br /> BLOCKING OR OTHER APPROVED MEANS USING UL LISTED WALL OPENING CONSULTANT: <br /> PROTECTIVE MATERIAL(I.E. PUTTY PADS). EC SHALL BE RESPONSIBLE FOR ANY <br /> FIRE BLOCKING AND SEALING SO AS NOT TO COMPROMISE FIRE OR STC(SOUND) <br /> RATING OF WALL ASSEMBLY. REFER TO ARCHITECTURAL DRAWINGS FOR <br /> LOCATIONS OF ALL RATED WALL ASSEMBLIES.SEE DETAIL 5/E5.2. <br /> I. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON E6 SERIES <br /> SHEETS FOR MORE INFORMATION REGARDING ELECTRICAL CONNECTIONS <br /> REQUIRED FOR MECHANICAL AND PLUMBING EQUIPMENT. <br /> J. FOR EACH VOICE/DATA LOCATION, PROVIDE 5"-SQ DEEP BACKBOX W/SINGLE <br /> MUDRING AND(1) 1"C WITH PULL STRING ROUTED TO ABOVE ACCESSIBLE CEILING <br /> G51 G1 AND TO TELEPHONE TERMINATION BOARD(TTB)IN TELECOM ROOM.SEE DETAIL ENGINEERING SYSTEM SOLUTIONS <br /> LL 4/E5.2. STRUCTURAL•MEP•BUILDING COMMISSIONIN <br /> K. PROVIDE CARBON MONOXIDEETECTORS W/INTEGRATED SOUNDER IN ALL BUILDING RELATIONSHIPS <br /> G51 (CO)( ) EXCEEDING EXPECTATIONS <br /> ROOMS WHERE FUEL-BURNING EQUIPMENT,APPLIANCES,OR FIREPLACES ARE www.es2eng.com <br /> G22 G2 LOCATED. ALSO PROVIDE A CO DETECTOR OUTSIDE ROOMS CONTAINING FUEL ava3NORTxzvTllEnsT,sTEn <br /> BURNING EQUIPMENT. CO DETECTORS ARE TO BE MONITORED BY THE FIRE ALARM IDAHO FALLS,IDAHO 83401 <br /> C G51 SYSTEM. CO DETECTORS ARE TO BE INSTALLED AS SPECIFIED BY THE PHONE:(208)552-9874 <br /> MANUFACTURER,NFPA 720 AND LOCAL REQUIREMENTS. COORDINATE ALL FUEL JOB NUMBER: 17.1 O19 <br /> G50 e° BURNING EQUIPMENT LOCATIONS W/MC. COORDINATE ALL CO DETECTOR <br /> EPL <br /> SYSTANS,DRAW B <br /> Aim DESIG E ARETHEIXCWSNEPROPERTYVEQJGM[CRMG <br /> LOCATIONS W/AHJ AND OWNER REQUIREMENTS. EM EGL '°"E ND EH NGTERTRGDDG®N N EGRMWTEGLTrP" <br /> C VNEENP.ALLRIGHIS ARE RESERVED.COPYRIGHI1018 ENGEJEEREJG SYSTEM EOLLTIVNE <br /> G21 A L. FOR EACH TV LOCATION„ PROVIDE 5"-SQ DEEP BACKBOX W/SINGLE MUDRING AND <br /> (1) 1"C WITH PULL STRING ROUTED TO ABOVE ACCESSIBLE CEILING AND TO <br /> TELEPHONE TERMINATION BOARD(TTB) IN TELECOM ROOM. SEE DETAIL 4/E5.2. <br /> D160 G51 M. FOR ALL T-STAT LOCATIONS, PROVIDE BACK BOX, MUDRING,AND 1/2"C TO <br /> G1 CORRESPONDING UNIT WITH PULL-LINE FOR CONTROL WIRING BY M.C. <br /> D235G33 G51 COORDINATE FINAL LOCATION AND ORIENTATION WITH M.C. FOR ADA/ACC ROOMS <br /> ELECTRICAL MOUNTING HEIGHTS SEE"ACCESSIBILITY NOTES-ELECTRICAL <br /> G20 O MOUNTING HEIGHTS"NOTES 1 -4 ON SHEET E0.1. <br /> G70 O R77 G51 C a <br /> G51 G51 G51 KEYNOTES 0 H H o S U 0 T [ES <br /> G51 G51 LY mL- RR00 <br /> ® SD G51 G2 G1 PROVIDE <br /> AND PLUBACKBOX W/SINGLE-GANG MUDRING G BELOW LOCATION <br /> UG CEE TO <br /> RECEPTACLE TO CONCEAL UNIT RD. COORDINATEEXACTG23 G31 G30 G2 T21 CORDE <br /> G32 T21 ® LOCATION AND ELEVATION W/MC PRIOR TO ROUGH-IN. <br /> G51 G2 FOR EACH GUEST ROOM TELEVISION LOCATION, INSTALL RECESSED TV WALL <br /> G51 G51 G32 ® G32 G51 BRACKET W/MUDRING. ROUTE DUPLEX BRANCH CIRCUITING TO RECEPTACLE IN <br /> PUNCH OUT IN BOTTOM OF RECESSED BOX.TELECOM CABLING TO BE INSTALLED <br /> G30 G31 G23 G23 G31 G30 IN 3/4"C(EMT)TO ALLOW FOR FUTURE UPDATES/MODIFICATIONS. ROUTE <br /> F7 <br /> SD SD TELECOM CABLING TO COAX/CAT6 RECEPTACLES IN PUNCH OUT IN TOP OF <br /> G51 a RECESSED BOX. PROVIDE(1)RG-59 COAX CABLE AND(1)CAT6 FROM TV OUTLET <br /> G51 <br /> R77 G51 G51 R77 CONTINUOUS TO NETWORK/TELECOM ROOM OR OF LOCATED ON EACH FLOOR. <br /> G51 T21 G51 ALL CABLING SHALL BE PROPERLY SUPPORTED AND SECURED. (SEE Q <br /> G51 ARCHITECTURAL GUEST ROOM ELEVATIONS FOR MORE INFORMATION AS WELL AS Z <br /> G2 G20® G51G20 AC <br /> EXACT MOUNTING HEIGHT BEHIND N.) O <br /> D235 <br /> G70 D2 5 G70 G20 PROVIDE J-BOX FOR DOORBELL TRANSFORMER(HEARING IMPAIRED ROOMS U <br /> ONLY). O <br /> G33 <br /> G21 PROVIDE 4-SQ BACKBOX W/SINGLE-GANG MUDRING ADJACENT TO ENTRY LIGHT <br /> G51 D160 G21 SWITCH FOR ADA DOORBELL DISABLE SWITCH-DO NOT GANG W/LIGHT SWITCH. <br /> p p G33 PROVIDE LABEL ADA DOORBELL DISABLE SWITCH. SWITCH SHALL DISCONNECT <br /> G21 D160 `W 120VAC POWER TO ADA DOORBELL SYSTEM. PROVIDE DOORBELL DISABLE <br /> � (EF-A SWITCH ONLY IN COMMUNICATION FEATURED GUEST ROOMS. <br /> AC G50 G50 C <br /> G22 PROVIDE 4-SQ BACKBOX W/SINGLE-GANG MUDRING AT ADA HEIGHT(46"48"AFF) <br /> ,� G1 G22 G22 ® ON CORRIDOR SIDE OF ADA HEARING IMPAIRED GUEST ROOM DOOR FOR ADA <br /> D231 DOORBELL PUSH BUTTON. PROVIDE DOORBELL PUSH BUTTON ONLY FOR <br /> COMMUNICATION FEATURED GUEST ROOMS. REFER TO HEARING IMPAIRED <br /> DOORBELL WIRING DIAGRAM DETAIL FOR MORE INFORMATION. <br /> 5 ENLARGED DBL QUEEN GUESTROOM SCALE: 1/4"=1'-0'. 3 ENLARGED KING SUITE GUESTROOM - " 1 ENLARGED KING GUESTROOM G23 PROVIDE 4-SQ BACKBOX W/SINGLE-GANG MUDRING AT 80"ADJACENT TO FIRE <br /> SCALE: 1/4"- 1'0 SCALE: 1/4"=1'0" ALARM NOTIFICATION APPLIANCE FOR ADA DOORBELL HORN/STROBE(ONLY o <br /> E4.2 J E4.2 E4.2 REQUIRED FOR ADA HEARING IMPAIRED GUEST ROOM). REFER TO HEARING <br /> IMPAIRED DOORBELL WIRING DIAGRAM DETAIL FOR MORE INFORMATION. <br /> a <br /> G24 FOR ACCESSIBLE ROOMS ONLY: PROVIDE WALL SWITCH TO CONTROL DRAPERY. <br /> ALSO PROVIDE J-BOX FOR ELECTRICAL CONNECTION TO MOTORIZED DRAPERY. <br /> COORDINATE EXACT LOCATIONS AND CONTROL REQUIREMENTS W/DRAPERY <br /> INSTALLER AND GC. <br /> G30 PROVIDE GUEST ROOM WALL MOUNTED SMOKE DETECTOR WITHIN 6"OF FINISHED p <br /> G22 CEILING. DETECTOR SHALL BE ADDRESSABLE(SYSTEM)TYPE W/AUDIBLE LOW U- <br /> FREQUENCY BASES AND SHALL ACTIVATE AN AUDIBLE ALARM IN THE GUEST <br /> G21 ROOM AS WELL AS ACTIVATE AN AUDIBLE AND VISUAL SUPERVISORY SIGNAL O <br /> U <br /> CONDITION AT MAIN FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR. Q <br /> THE SUPERVISORY SIGNAL SHALL INCLUDE A VISUAL DISPLAY OF THE GUEST <br /> M G33 ROOM NUMBER IN ALARM. <br /> LL <br /> O <br /> G31 FOR ALL GUEST ROOMS: PROVIDE FIRE ALARM HORN NOTIFICATION DEVICE IN U <br /> _- D G22 SLEEPING AND LIVING AREA. a <br /> O <br /> D160 AC G32 FOR HEARING IMPAIRED GUEST ROOMS: PROVIDE FIRE ALARM HORN STROBE p O <br /> G50 DEVICE(AUDIO AND VISUAL NOTIFICATION). PROVIDE ADDITIONAL VISUAL U J <br /> F �933 <E STROBES IN SLEEPING AREA IF SEPARATED BY DOOR. <br /> G20 235 <br /> G22 <br /> G21 <br /> D160 G33 FOR HEARING IMPAIRED GUEST ROOMS: PROVIDE ADDITIONAL VISUAL STROBE <br /> G21 INDICATORS FOR FIRE ALARM,SMOKE ALARM AND ANNUNCIATOR SYSTEMS IN <br /> o G70 G50 BATHROOM.SEE HEARING IMPAIRED DOORBELL WIRING DEAGRAM DETAIL FOR <br /> 53 R77 D235 M MORE INFORMATION. COORDINATE EXACT LOCATIONS WITH G.C.AND CONNECT REVISIONS: <br /> G51 G33 COMPLETE. 2 FRANCHISE 11/06/18 <br /> SD <br /> SII G2069 G50 PER CALIFORNIA ENERGY CODE 130.1(C)8, CAPTIVE CARD KEY CONTROLS SHALL <br /> G30 G31 G23 D160 <br /> G70 BE INSTALLED WITH SIGNAGE TO CONTROL ALL PERMANENTLY INSTALLED <br /> G32 R77 LUMINAIRES AND SWITCHED RECEPTACLES IN GUEST ROOM.SEE GUESTROOM <br /> G51 G51 G51 D235 CONTROL DETAIL FOR MORE INFORMATION. <br /> m SD ® G51 FOR SWITCHED RECEPTACLES IN GUEST ROOMS,THE RECEPTACLES SHALL BE <br /> m G30 G31 G23 G20 CONTROLLED BY CAPTIVE CARD KEY CONTROLS,SEE GUEST ROOM CONTROL <br /> T21 G32 DETAIL FOR MORE INFORMATION. <br /> ® 651 <br /> T21 o G70 G70 PROVIDE SPLIT WIRED DUPLEX RECEPTACLE BEHIND MICROWAVE.CONTROL(1) <br /> G51 92 ® OUTLET(TOP)W/GUEST ROOM MASTER LIGHT SWITCH AND LEAVE(1)OUTLET <br /> G51 G51 G51 (BOTTOM)UNCONTROLLED FOR MICROWAVE.SWITCHED OUTLET TO CONTROL BA PROJECT# 161010 <br /> - SD 0 ® DOWNLIGHT PROVIDED W/CASEWORK. PROVIDE PERMANENT MARKINGS TO PLN PROJECT# 17077 <br /> CG3 G31 G23 DIFFERENTIATE CONTROLLED FROM UNCONTROLLED RECEPTACLES. <br /> G2 COORDINATE PERMANENT MARKINGS W/ARCHITECT PRIOR TO INSTALLATION. MARRIOTT# 4476 <br /> G51 G51 G32 T21 COORDINATE WORK W/GC AND CONNECT COMPLETE. <br /> Fm <br /> G51 T21 PROPOSED LOCATION FOR WIRELESS ACCESS POINT(WAP). PROVIDE CEILING PERMIT# - <br /> U G51 CG_51 ® ® MOUNTED DATA JACK WITH A 25COILED LOOP OF CABLE ABOVE THE CEILING. <br /> a� <br /> LOCATIONS AND EXACT NUMBER OF WAP'S ARE APPROXIMATE. FINAL LOCATIONS APN# 058-66-012 <br /> G51 G51 AND QUANTITY ARE TO BE DETERMINED BY DATAICOMM UN I CATIONS <br /> Q <br /> G51 CONTRACTOR TO ENSURE FULL WIRELESS COVERAGE. <br /> DATE: 4/15/19 <br /> G51 G51 G2 G51 DRAWN: DW <br /> CHECKED: JC <br /> G51 <br /> 951 <br /> 62 <br /> SHEET TITLE: <br /> G51 <br /> G51 G51 ENLARGED <br /> 62 O ELECTRICAL PLANS <br /> G24 c <br /> 68 91 G51 G51 $ G1 <br /> G51 G24 G1 G51 <br /> 6 ENLARGED ACC. DOUBLE QUEEN SCALE: 1/4"=1'-0" 4 ENLARGED ACC. KING SUITE SCALE: 1/4"=1'0" 2 ENLARGED ACC. KING GUESTROOM SCALE: 1/4"=1'-0° <br /> � �� SHEET NO.: <br /> 3 <br /> c� <br /> L <br /> r <br /> E4.2 <br />