CA GREEN CODE REQUIREMENTS I m
<br /> 1. PER CALGREEN SECTION 5.303.2, PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN
<br /> IN TABLE 5.303.2.3. EXCEPTION: BUILDING THAT DEMONSTRATE 20% OVERALL WATER USE REDUCTION. IN THIS
<br /> CASE, A CALCULATION DEMONSTRATING A 2% REDUCTION IN THE BUILDING "WATER USE BASELINE," AS
<br /> ESTABLISHED IN TABLE 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATIONS TO
<br /> THE BUILDING.
<br /> MAXIMUM FIXTURE FLOW RATES:
<br /> FIXTURE TYPE MAXIMUM FLOW RATE
<br /> LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM ® 60 PSI
<br /> KITCHEN FAUCETS 1.8 GPM @ 60 PSI z
<br /> METERING FAUCETS 0.25 GALLONS/CYCLE O
<br /> WATER CLOSETS 1.28 GALLONS/FLUSH
<br /> URINALS 0.5 GALLONS/FLUSH U
<br /> w
<br /> 2. PER CALGREEN SECTION 5.303.3.1, THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT
<br /> EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE
<br /> CRITERIA OF THE US EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE
<br /> FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO
<br /> REDUCES FLUSHES AND ONE FULL FLUSH.
<br /> 3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE
<br /> DEPOSITING, STORAGE, AND COLLECTION OF NONHAZARDOUS MATERIALS FOR RECYCLING. PER SECTION
<br /> 5.410.1.1 ANY ADDITION OR ALTERATION RESULTING IN LESS THAN A 30% INCREASE IN THE TENANT SPACE
<br /> FLOOR AREA IS EXEMPT FROM THIS REQUIREMENT.
<br /> 4. PER CALGREEN SECTION 5.504.3, AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br /> CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL
<br /> DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, w
<br /> SHEET METAL, OR OTHER APPROVED METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH I Q
<br /> MAY ENTER THE SYSTEM. o
<br /> 5. PER CALGREEN SECTION 5.504.4.1, ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS,
<br /> SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH TABLE 5.504.4.1 AND 5.504.4.2. I w
<br /> SEALANT VOC LIMIT: ARCHITECT OF RECORD:
<br /> ARCHITECTURAL 250
<br /> MARINE DECK 760 ARch'i�
<br /> NONMEMBRANE ROOF 300 v CRAIG S.
<br /> ROADWAY 250 BL?M
<br /> SINGLE-PLY ROOF MEMBRANE 450 NO.-C-31661
<br /> OTHER 420 REN.3/31/2021 (n
<br /> 6. PER CALGREEN SECTION 5.504.4.3, ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE yd NY
<br /> 5.504.4.3. �yi HO �O
<br /> VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS:
<br /> INDOOR CARPET ADHESIVES 50 pj
<br /> CARPET PAD ADHESIVES 50 NAPA Z
<br /> OUTDOOR CARPET ADHESIVES 150 � , O
<br /> WOOD FLOORING ADHESIVES 100 3
<br /> RUBBER FLOOR ADHESIVES 60
<br /> SUBFLOOR ADHESIVES 50 411
<br /> CERAMIC TILE ADHESIVES 65
<br /> VCT AND ASPHALT TILE ADHESIVES 50
<br /> DRYWALL AND PANEL ADHESIVES 50
<br /> COVE BASE ADHESIVES 50
<br /> MULTIPURPOSE CONSTRUCTION ADHESIVES 70 W
<br /> STRUCTURAL GLAZING ADHESIVES 100 m
<br /> SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 o P
<br /> OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 O U
<br /> s
<br /> SPECIALTY APPLICATIONS PVC WELDING 510 a w
<br /> w 0 3
<br /> CPVC WELDING 490 .N o� 1
<br /> ABS WELDING 325
<br /> PLASTIC CEMENT WELDING 250
<br /> ADHESIVE PRIMER FOR PLASTIC 550 0 �, ; p o w 0) N
<br /> CONTACT ADHESIVE 80 Q CJ 0 2 t 0 ° ' o
<br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 ° J a 0 p CO
<br /> STRUCTURAL WOOD MEMBER ADHESIVE 140 0 ° Ls
<br /> C'_ O N'pp V a p
<br /> TOP AND TRIM ADHESIVE 250 J E ° N c
<br /> SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 0 !, o 3 N 'o� �,
<br /> PLASTIC FOAMS 50 o °
<br /> POROUS MATERIAL (EXCEPT WOOD) 50 = '00 c: o
<br /> WOOD 30 0 �, u o c°'rn a
<br /> N o C_•;6 p y Lo
<br /> FIBERGLASS 80 0 o,o o °c o
<br /> troy, ° pc
<br /> 7. PER CALGREEN SECTION 5.504.4.3.2, VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED .� m- " °' p
<br /> _ c c+. m
<br /> AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE v 0'c�' 00, 0
<br /> p °+ x�
<br /> FOLLOWING: C U L U - N E N
<br /> 1. MANUFACTURER'S PRODUCT SPECIFICATION ° J~ `- ° 0
<br /> 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS Q j•°- p c
<br /> � c a o
<br /> O ° — N 10 w
<br /> taA'�'O V O U N
<br /> 8. PER CALGREEN SECTION 5.504.4.6, RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH THE VOC-EMISSION
<br /> � p� °aai
<br /> LIMITS DEFINED IN THE 2012 CHPS CRITERIA AND LISTEN ON ITS HIGH PERFORMANCE PRODUCTS DATABASE, o 0 0 �, ,o a
<br /> PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGAURD CHILDREN & SCHOOLS V o T O
<br /> PROGRAM, CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE, OR �'��`, ° a�
<br /> °
<br /> SHALL MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION. O
<br /> L� p 0 3 p o p O p
<br /> Q01 00
<br /> 9. PER CALGREEN SECTION 5.508.1, RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE a (n Ho r Z °
<br /> NONHAZARDOUS CONSTRUCTION OR DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2, OR w s �•- O °0 N 0
<br /> �
<br /> 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS a
<br /> MORE STRINGENT.
<br /> ui
<br /> } o m z ui U N
<br /> 10. PER CALGREEN SECTION 5.504.1.3, TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM 0° w w o 0 _JCn \ - c`oo
<br /> SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR Q N N `� N UJ uia C14AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL [if Ln z w QI
<br /> AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN Q o Q [If 0 0vi c)
<br /> AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE c
<br /> 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE
<br /> ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING
<br /> ALTERATION AT THE CONCLUSION OF CONSTRUCTION.
<br /> 0)
<br /> Q
<br /> 11. PER CALGREEN SECTION 5.504.3, COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL
<br /> EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE o
<br /> CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT
<br /> AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC,
<br /> SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF
<br /> DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM.
<br /> ui
<br /> 12. PER CALGREEN SECTION 5.504.7, ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR cf) a
<br /> AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR U o z N
<br /> INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR CD a -
<br /> REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITYz
<br /> AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS U 0 W � (nQ
<br /> OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR Q _jQ ? w °'
<br /> POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. m o w o w
<br /> Q
<br /> m z w w
<br /> Q CD o N
<br /> (0z w
<br /> Q
<br /> J
<br /> 0 U Z 00
<br /> O- d w w r
<br /> � U) LLJ o N
<br /> o ww o F- o
<br /> w
<br /> 0 GN1 . 1
<br /> _
<br /> 0 GENERAL NOTES
<br />
|