REVISIONS 13Y <br /> ELECTRICAL SYMBOLS ABBREVIATIONS LIGHTING: <br /> (SOME SYMBOLS ARE SHOWN FOR REFERENCE ONLY) <br /> 16. ALL LOW VOLTAGE CONTROLS AND CONTROL WIRING SHALL BE PROVIDED BY THE CONTRACTOR THAT <br /> 2X4 RECESSED CEILING FIXTURE s s FLUSH OR SURFACE MOUNTED BRANCH CIRCUIT PANEL AFF ABOVE FINISHED FLOOR GEN GENERATOR PB PULL BOX FURNISHES THE EQUIPMENT. ALL LINE VOLTAGE WIRING SHALL BE PROVIDED & UNDER THIS <br /> AL ALUMINUM CONDUCTOR OR BUS GFI GROUND FAULT INTERRUPTER PE PHOTO ELECTRIC CELL CONTRACT. <br /> RECESSED FIXTURE - CEILING (SHADED = FIXTURE WITH INTEGRAL SWITCHBOARD OR DISTRIBUTION BOARD AM AMMETER GND GROUND PNL PANEL <br /> EMERGENCY BATTERY) ANN ANNUNCIATING PR PAIR 17. COORDINATE WITH ANY PROJECT DESIGN/BUILD TRADES FOR EXACT DATA AND LOCATION OF ALL <br /> COMBINATION STARTER DISCONNECT SWITCHEQUIPMENT. PROVIDE LINE VOLTAGE OUTLETS, WIRING AND DISCONNECTING MEANS. ALL OUTDOOR <br /> 0 4-FT LIGHT FIXTURE, SURFACE OR RECESSED MOUNTED. DISCONNECT SWITCH ART ARTICLE HGP HEIGHT WIRING SHALL BE WEATHERPROOF. CON5ULTANT <br /> AUTO AUTOMATIC HP HORSE POWER QTY QUANTITY <br /> I--o-� 4 FOOT INDUSTRIAL STRIP LIGHT F DISCONNECT SWITCH, MOTOR RATED, "F" INDICATES SWITCH TO AUX AUXILIARY HPS HIGH PRESSURE SODIUM 18. STARTERS TO BE FURNISHED AND INSTALLED BY TRADE SUPPLYING MOTOR. CONNECTION BY E.C. <br /> BE FURNISHED WITH FUSES, SIZE TO EQUIPMENT NAMEPLATE DATA. AWG AMERICAN WIRE GAGE HTR HEATER R REMOVE OR RELOCATE z2,b,,g C N565 <br /> Pittsburg,CA 94565 <br /> 4 FOOT INDUSTRIAL STRIP LIGHT WITH HW HOT WATER REC RECEPTACLE 9h,,,(5,6,289,228 <br /> I--�� 19. FURNISH & INSTALL AN APPROPRIATE DISCONNECT SWITCH FOR ALL EQUIPMENT. USE W.P. ema pdq @gede°efgYL-1ti°g- <br /> BATTERY PACK ON NIGHT LIGHT OR EMERGENCY CIRCUIT EMERGENCY POWER OFF (PANIC BUTTON) BD BOARD RECEPT RECEPTACLE OUTDOORS. 120V. REQUIRES A S.P. MOTOR RATED SWITCH. 208V REQUIRE A DISCONNECT SWITCH. <br /> BKBD BACK BOARD IG ISOLATED GROUND REF REFRIGERATOR; REFERENCE ENERGY CONSUL TING <br /> , & ENGINEERING SERVICES <br /> r� 0 � 'M' DENOTES HORSEPOWER WHEN KNOWN. BKR BREAKER INCAND INCANDESCENT REQ'D REQUIRED www.geaenergyconsult/ng.cory <br /> i--�� 8 FOOT INDUSTRIAL STRIP LIGHT WITH BATTERY JUNCTION BOX OR OUTLET FOR DIRECT CONNECTION; BTM BOTTOM RL RELOCATED MISC: <br /> PACK ON NIGHT LIGHT OR EMERGENCY CIRCUIT a VERIFY HT. IN FIELD JB JUNCTION BOX <br /> CAB CABINET SCHED SCHEDULE Q�pFESS�oN <br /> O FLUORESCENT OR LED DOWN LIGHT M/H MICROWAVE / HOOD CONNECTION ONLY - F&IBO; CB CIRCUIT BREAKER KV KILOVOLT SECT SECTION 20. ALL PENETRATIONS IN FIRE RATED WALLS AND CEILINGS SHALL COMPLY WITH CEC 300-21. �p NN.B4, �l <br /> CCN CLOSED CIRCUIT TELEVISION KVA KILOVOLT AMPERE SIM SIMILAR ��� \�a �, `G, <br /> > WALL WASHER TYPE FIXTURE. DIRECTION AS INDICATED VERIFY REQUIREMENTS IN FIELD CKT CIRCUIT KW KILOWATT SQ SQUARE 21 . ALL MULTIWIRE BRANCH CIRCUITS SHALL COMPLY WITH 2016 CEC SECTION 210.4 FOR SIMULTANEOUS Z <br /> ON MARK-UP R 250 VOLT RECEPTACLE U.O.N. (D = 30 AMP FOR DRYER PLUG CO CONDUIT ONLY SW SWITCH DISCONNECT AND GROUPING OF THESE CIRCUITS. Lu No. 21313 <br /> IN UNIT; R = 50 AMP FOR ELECTRIC RANGE CU COPPER CONDUCTOR OR BUS LT LIGHT SWBD SWITCHBOARD Exp.09-30-21 <br /> I-O WALL MOUNTED LIGHT FIXTURE ® ) 22. GENERAL USE OUTLET MOUNTING HEIGHTS AREAS SHALL BE NOT LESS THAN 15 INCHES ABOVE � � <br /> DUPLEX RECEPTACLE MOUNTED ON CEILING LTG LIGHTING SWGR SWITCHGEAR s <br /> FINISHED FLOOR F TO THE <br /> WALL SCONCE ON NORMAL SOURCE CIRCUIT. SHADE FOR DD DUCT DETECTOR SYS SYSTEM SHALL BENO MORETHAN 48 INCHES OMFEOUTLET. <br /> CONTROL THEOUTWITCH MOUNTING HEIGHTS <br /> LET BOX. �gTFOF CAL1Fp��\ <br /> EMERGENCY CIRCUIT ® QUADRUPLEX RECEPTACLE MOUNTED ON CEILING DIA DIAMETER MAX MAXIMUM <br /> CEILING OR WALL MOUNTED EXIT SIGN DUPLEX RECEPTACLE MOUNTED ON WALL MINIMUM OF 15 INCHES DIM DIMENSION MCB MAIN CIRCUIT BREAKER TBD TO BE DETERMINED 23. ALL ELECTRICAL WORK SHALL COMPLY WITH LATEST EDITION OF NEC AS AMENDED BY THE 2016 CEC, <br /> DISC DISCONNECT MCC MOTOR CONTROL CENTER TC TIME CLOCK CEC 2016 TITLE 24. <br /> . INDICATES INTEGRAL EMERGENCY HEAD � MEASURED TO THE BOTTOM OF THE RECEPTACLE OUTLET BOX <br /> CEILING OR WALL MOUNTED EXIT SIGN. ARROWS INDICATEDN DOWN MCM MILLI CIRCULAR MILS TEL TELEPHONE <br /> PATH OF EGRESS. OR RECEPTACLE HOUSING ABOVE FINISHED FLOOR. DS DISCONNECT SWITCH MIN MINIMUM TEMP TEMPORARY; TEMPERATURE 24. LIGHTING FIXTURE IN FIRE RATED CEILING SHALL BE FIRE RATED OR PROVIDED WITH FIRE RATED <br /> MISC MISCELLANEOUS TI TENANT IMPROVEMENT ENCLOSURE OR FIRE RATED PAD. <br /> 0 NEW EMERGENCY LIGHTING WITH BATTERY BACK-UP. QUADRUPLEX RECEPTACLE MOUNTED ON WALL +15" A.F.F. U.O.N. (E) EXISTING MLO MAIN LUG ONLY TRANS TRANSFORMER <br /> a v 90 MIN BATTERY (E) = EXISTING (ER) EXISTING TO REMAIN MTD MOUNTED TTB TELEPHONE TERMINAL BACKBOARD 25. ELECTRICAL WORK SHALL COMPLY WITH LATEST EDITION OF NATIONAL ELECTRICAL CODE (NEC) AS <br /> ® LANDSCAPE RECESSED GROUND UPLIGHT DEDICATED RECEPTACLE MOUNTED ON WALL +15" A.F.F. U.O.N. EA EACH MTG MOUNTING TV TELEVISION AMENDED BY THE 2016 CALIFORNIA ELECTRICAL CODE (CEC), THE 2016 CALIFORNIA BUILDING ENERGY <br /> EC ELECTRICAL CONTRACTOR MTR MOTOR TYP TYPICAL EFFICIENCY STANDARDS, TITLE 24, PARTS 20 AND 24 (CEnC). <br /> EM EMERGENCY <br /> LANDSCAPE BOLLARD LIGHT QUADRUPLEX RECEPTACLE ON A DEDICATED CIRCUIT EQ EQUAL <br /> N NORTH UC UNDER CABINET <br /> EQUIP EQUIPMENT NC NORMALLY CLOSED UG UNDERGROUND <br /> POLE LIGHT, HEADS AS SHOWN; SHADED = ON EMERGENCY CIRCUIT km HALF SWITCHED DUPLEX RECEPTACLE EX EXPLOSION PROOF <br /> NEC NATIONAL ELECTRIC CODE UL UNDERWRITERS LABORATORY <br /> Q TREE UPLIGHTS I� 208V, 60A RECEPTACLE, NEMA CONFIGURATION EXH EXHAUST NEUT NEUTRAL UON UNLESS OTHERWISE NOTED <br /> TO BE VERIFIED WITH OWNER, U.O.N. FA FIRE ALARM NIC NOT IN CONTRACT V VOLT <br /> 208V, 20A RECEPTACLE, NEMA 6-20R CONFIGURATION FAAP FIRE ALARM ANNUNCIATING PANEL NO NORMALLY OPEN W WALL MOUNTED; WATT <br /> -[==T STEP LIGHTS; SHADED = ON EMERGENCY CIRCUIT TO BE VERIFIED WITH OWNER, U.O.N. FACP FIRE ALARM CONTROL PANEL NTS NOT TO SCALE W/ WITH <br /> $3 $A SINGLE POLE SWITCH (2-POLE, 3-WAY OR 4-WAY; D=DIMMER 1000W 20A RECEPTACLE, NEMA 5-15R CONFIGURATION FBO FURNISHED BY OTHERS OL OVERLOAD W/O WITH OUT <br /> SLIDE TYPE IF NOTED) 48 AFF TO TOP OF DEVICE BOX - U.O.N. TO BE VERIFIED WITH OWNER, U.O.N. FIN FINISH WP WEATHER PROOF <br /> 20A RECEPTACLE, NEMA 5-20R CONFIGURATION FLA FULL LOAD AMPS OCS OCCUPANCY SENSOR XFMR TRANSFORMER <br /> Q DIMMER SWITCH - 48" T.O.D. U.O.N. TO BE VERIFIED WITH OWNER, U.O.N. FSD FIRE SMOKE DAMPER <br /> N VACANCY SENSOR SWITCH 48" AFF TO TOP OF DEVICE BOX - U.O.N. 480V, 30 RECEPTACLE NEMA CONFIGRATION FUT FUTURETO BE VERIFIED WITH OWNER, U.O.N. <br /> 4 LIGHTING OCCUPANCY SENSOR WALL MTD +48" AFF TO TOP OF DEVICE BOX. DUPLEX GFCI RECEPTACLE ABOVE COUNTER <br /> OS CEILING MOUNTED MOTION SENSOR ® CORD DROP RECEPTACLE GENERAL NOTES <br /> Q <br /> � z <br /> ®S CEILING MOUNTED DAYLIGHT SENSOR FD CATV OUTLET L O <br /> 1. ALL BATHROOM, OUTDOOR, AND KITCHEN COUNTER RECEPTACLES WITHIN SIX FEET OF A SINK ARE TO <br /> SD CEILING MOUNTED SMOKE DETECTOR HOME NETWORK OUTLET FOR TV, PHONE, DATA BE GFCI PROTECTED. LZ <br /> 2. WALL MOUNTED OUTLETS DRAWN IN A LINE, OUT FROM THE WALL, SHALL BE CENTERED ABOVE EACH ( u _ <br /> THERMOSTAT COMBO DUPLEX RECEPTACLE & DUAL USB OUTLET - 15" BOD - LION OTHER, AT SCHEDULED HEIGHTS. MOUNT ALL BOXES ON SAME SIDE OF STUD. USE BAR HANGERS v \ W <br /> OR SCRAP BLOCKS TO CENTER THE BOXES TO EACH OTHER. � L j Q <br /> © CEILING MOUNTED CARBON MONOXIDE DETECTOR FOR COMBPENIINSULA ORO DUPLEX CIISLAND PCOULNT R MOA NT NO L USB OUTLET <br /> THAN 162" BELOW CTR. 3. ELECTRICAL OUTLETS LOCATED ON OPPOSITE SIDES OF ALL FIRE-RATED WALLS SHALL BE SEPARATED L� z <br /> BY A HORIZONTAL DISTANCE OF AT LEAST 24 INCHES. r C Q <br /> D CEILING MOUNTED HEAT DETECTOR IO DOOR BELL v 1 <br /> 4. WHEN KITCHEN OR BATH OUTLETS AT WALLS CANNOT BE MOVED TO THE NEXT STUD BAY, FILL THE CD <br /> [T1S] TIME SWITCH - 48" AFF TO TOP OF DEVICE BOX - U.O.N. 2A ELEVATOR PIT DUPLEX RECEPTACLE, LIGHT AND SWITCH STUD BAY (OR PORTION OF) WITH FIRE RETARDANT MATERIAL SATISFACTORY TO LOCAL BUILDING / __j Q z <br /> FIRE INSPECTION. -1 Q <br /> PHOTOCELL (ADJUSTABLE), ROOF OR WALL MOUNTED, PROVIDE MOUNTING r <br /> © PC SUPPORT AS REQUIRED ® FLUSH FLOOR DUPLEX RECEPTACLE 5. PROVIDE A W.P. RECEPTACLE NO FARTHER THAN 25 FEET FROM ANY OUTDOOR EQUIPMENT. O v J <br /> SIMILARLY, PROVIDE A STANDARD RECEPTACLE FOR EQUIPMENT IN ATTICS OR MECHANICAL ROOMS. CD W <br /> PP POWER PACK RELAY ® FLUSH FLOOR QUADRUPLEX RECEPTACLE <br /> 6. PROVIDE DISCONNECTING MEANS FOR ALL EQUIPMENT REQUIRING SUCH. � O <br /> LOW VOLTAGE MULTI-CONDUCTOR CABLE - PLENUM RATED FLUSH FLOOR TELEPHONE OUTLET 7. OUTLET BOXES LOCATED IN 1 HOUR RATED WALLS AND CEILINGS SHALL BE STEEL OR 1 HOUR FIRE z <br /> LV WHERE REQUIRED, NOT INSTALLED IN CONDUIT. RATED PLASTIC AND SHALL HAVE ANNULAR SPACE SEALED WITH 1 HR RATED FIRE STOPPING. PER <br /> CONDUIT - CONCEALED IN WALLS OR CEILING IF POSSIBLE, 1/2" WITH FLUSH FLOOR COMBINATION CEC 300-21 AND CBC-709, 710. <br /> (2) #12 THHN/THWN Cu & (1) #12 THHN/THWN Cu GROUND U.O.N. ® TELEPHONE/DATA OUTLET <br /> 8. ALL PLASTIC CONDUIT OR CABLE IN 1 HR WALLS SHALL HAVE A F RATING. <br /> CONDUIT - IN OR BELOW FLOOR, 3/4" WITH (2) #12 THHN/THWN Cu ® <br /> & (1) #12 THHN/THWN Cu GROUND U.O.N. ° FLUSH FLOOR RECEPTACLE AND TELEPHONE BOX <br /> CONDUIT - EXPOSED, 1/2" WITH (2) #12 THHN/THWN Cu <br /> & (1) #12 THHN/THWN Cu GROUND U.O.N. Ia DATA OUTLET <br /> z <br /> TYPE MC CABLE 3/C #12 WITH GND (MINIMUM NUMBER <br /> OF CONDUCTOR AND WIRE SIZE) I� TELEPHONE OUTLET +15" AFF UON O <br /> TV/DATA/ TELEPHONE OUTLETS (1-RJ45; 1-RJ11 JACKS) CAT 6 [L <br /> TRANSFORMER, 2 WINDING CABLE (4PK) EACH JACK AND 1 "F" CONNECTOR W/ DUAL COAXIAL LIGHTING: \ <br /> D - DELTA CABLE TO TERMINATE AT COMMUNICATION BOX (/)-INDICATES ABOVE 0 O / O <br /> Y - WYE COUNTER 9. ALL WALL MOUNTED FIXTURES ARE TO BE LOCATED AT HEIGHTS ESTABLISHED BY ARCHITECT. u-J N <br /> HEIGHTS ARE TO BE SET AFTER SUBMITTALS ARE APPROVED. (FINAL FIXTURES SIZES ARE KNOWN.). _J = z Ln <br /> - WYE GROUNDED NEUTRAL „_ <br /> DP DOUBLE POLE, SINGLE THROW HORSE POWER RATED SWITCH WITH THERMAL v U , ` <br /> T OVERLOAD w v Q <br /> z w U <br /> ® UTILITY KWH METERsEc SECURITY CAMERA Luz • <br /> zw z � o <br /> 1 WF1 PROVIDE 1 CAT 6 CABLE WIRELESS INTERNET CONNECTION, VERIFY LOCATION <br /> 150 J MOLDED CASE CIRCUIT BREAKER, "100" EQUALS TRIP RATING, WITH IT CONSULTANT <br /> 100 (3) / "3" INDICATES NUMBER OF POLES, "150" EQUALS FRAME SIZE. SERVICE & DISTRIBUTION: z <br /> 1 F� FIRE DEPARTMENTS 2-WAY COMMUNICATION HANDSET <br /> DRAWING INDEX. <br /> weq WIRELESS CARD RECEIVER 10. COORDINATE WITH HVAC, PLUMBING AND SPRINKLER CONTRACTORS: NO PIPING OR DUCTWORK IS TO <br /> 100A I > I ENCLOSED MOLDED CASE CIRCUIT BREAKER, 100 EQUALS TRIP RATING, PASS THROUGH SWITCHGEAR ROOM OR PROTRUDE BELOW THE STRUCTURAL CEILING OVER THE SHEET NO. DESCRIPTION W <br /> 3P I / I "3P" INDICATES NUMBER OF POLES. SWITCHGEAR ROOM. REVIEW FINAL "CONSTRUCTION" PLUMBING, SPRINKLER AND HVAC SHOP E1.0 SYMBOL LISTS, GENERAL NOTES, ABBREVIATIONS AND INDEX <br /> L i J DH DH DOOR HOLDER - CONNECT TO LOCAL SMOKE DETECTOR DRAWINGS. IF SUCH CONFLICTS EXIST, NOTIFY ARCHITECT AT ONCE. <br /> E1.1 ELECTRICAL SITE PLAN <br /> %� Ds DUCT SMOKE DETECTOR - F & IBO; CONNECT TO FIRE ALARM PANEL. E1.2 EXTERIOR LIGHT PHOTOMETRIC CALCULATION <br /> DRAWOUT INSULATED CASE OR AIR CIRCUIT BREAKER WITH 11. CONTRACTOR TO VERIFY ACTUAL AIC RATINGS FOR ALL EQUIPMENT FROM PG&E. SUBMITTING ON E2.0 SINGLE LINE DIAGRAM AND PANEL SCHEDULES <br /> INDICATIONS ABOVE.� EQUIPMENT BELOW ACTUAL RATING DOES NOT RELIEVE CONTRACTOR OF NOTED RESPONSIBILITY.% FIRE/SMOKE DAMPER, PROVIDED & INSTALLED BY MECHANICAL CONTRACTOR. E2.1 TYPICAL DETAILS <br /> Fso PROVIDE 120V 1 PHASE EMERG. CIRCUIT, CONTROL, AND STATUS 12. USE C.L. FUSED MAINS. ALL BREAKERS IN SERVICE ROOM EQUIPMENT SHALL BE RATED TO MEET E3.0 GROUND AND SECOND FLOOR POWER AND SIGNAL PLAN DATE <br /> EQUIPMENT GROUND FAULT DETECTION WITH WIRING TO FACP (LIFE SAFETY SYSTEM.) PG&E FAULT CURRENT REQUIREMENTS. 03/05/2020 <br /> GF TP E3.1 ELECTRICAL ROOF PLAN <br /> TEST/MONITOR PANEL. 13. PROVIDE A DISCONNECTING MEANS FOR THE GROUNDED CONDUCTOR PER CEC 230 - 75. E4.0 GROUND AND SECOND FLOOR LIGHTING PLAN SCALE <br /> MISC' 14. ELECTRICAL CONTRACTOR (E.C.) TO PROVIDE OWNER WITH ONE SET OF SPARE FUSES FOR EACH E5.0 TITLE 24 INTERIOR A5 5110WN <br /> � <br /> 1 FUSED SWITCH, CLASS L OR R FUSES AS NOTED. "100" INDICATES SIZE OF FUSE USED IN PROJECT. E5.1 TITLE 24 POWER DISTRIBUTION <br /> DRAWN <br /> SWITCH SIZE, "70" INDICATES FUSE SIZE, "3" INDICATES POLES. 15. NO FEEDERS SHALL BE RUN IN SLABS, RACK IN CEILING OF GARAGE AND/OR ABOVE IN ATTIC GEA <br /> 70 (3) O1 GENERAL NOTE SYMBOL SPACES. <br /> JOB <br /> LIGHTING FIXTURE TAG, SEE LIGHTING FIXTURE SCHEDULE AND FLOOR <br /> PLAN(S) <br /> O SHEET NOTE SYMBOL SHEET <br /> Al REVISION REFERENCE SYMBOL - SEE ASSOCIATED REVISION NOTE. '00 <br />