Laserfiche WebLink
REV15ION5 BY <br /> SAWCUT PAVING TO MATCH GENERAL NOTES : <br /> EXISTING TABLE 2-1 MINIMUM SEPARATION AND CLEARANCE REQUIREMENTS FOR SERVICE TRENCHES <br /> FINISHED GRADE G DUCT DB C S <br /> T T <br /> 1. ELECTRICAL SITE PLAN IS SCHEMATIC IN NATURE. CONTRACTOR SHALL COORDINATE WITH THE <br /> (ALL NUMBERS IN INCHES) OWNER/ARCHITECT, UTILITY COMPANY, AND VERIFY THE SITE PRIOR TO INSTALLATION OF ALL <br /> G (GAS) SEE NOTES 4,7 AND 13(1) - 12 12 12 6 ELECTRICAL EQUIPMENTS. <br /> 12" ��\\/\\' ° p %/\/// -0" MIN. TO ALLOW T (TELEPHONE) DUCT 12 - 1 1 12 2. INSTALLATION MUST COMPLY WITH PG&E REQUIREMENTS. <br /> 24" MIN. t? j\ FOR FUTURE EXPANSION T (TELEPHONE) DIRECT BURY 12 1 — 1 12 <br /> \ a / CONSULTANT <br /> COVER FOR / \D C (CATV) 12 1 1 — 12 3. PROVIDE A SEPARATE NEUTRAL CONDUCTOR FOR EACH AND EVERY PHASE (LINE) <br /> SECONDARY WARNING TYPE II BACKFILL MATERIAL CONDUCTOR; TO COMPLY WITH CEC ARTICLE 210.4 FOR MULTI—WIRE CIRCUITS AND TO <br /> CONDUIT TAPE �� (90% COMPACTION) S (ELECTRIC SECONDARY) 6 12 12 12 — PERMIT INDIVIDUAL OPERATION/CONTROL OF EACH BRANCH CIRCUIT OR PROVIDE TIE HANDLE 2249T"sa <br /> 6 4 / P (ELECTRIC PRIMARY) 12 12 12 12 3 ON BREAKERS TO SUIT SINGLE NEUTRAL ON MULTI—CIRCUITS HOMERUNS— NEUTRAL MUST , P'(519,CAN 565 <br /> phone'.(510)288-1128 <br /> © d <br /> @@ QUANTITY AS SL (STREETLIGHT) SEE NOTE 2 BELOW 6 12 12 12 BE MINIMUM #10 ON MULTI CIRCUITS.NEEDED <br /> > T T QUANTITY AS (1) FOR MORE INFORMATION CONCERNING TABLE 2-1, INCLUDING THE NOT REFERENCED ENERGY CONSULTING <br /> ROCK—FREE EARTH BACKFILL IN THE TABLE AND IN FIGURE 2-4, SEE SVP'S "JOINT TRENCH CONFIGURATIONS 4. ELECTRICAL PLANS ARE INTENDED TO SHOW IN A GENERAL WAY, THE APPROXIMATE & ENGINEERING SERVICES <br /> (90% COMPACTION) -a NEEDED LOCATION AND LOADS OF THE INTENDED FIXTURE AND EQUIPMENT. EXACT LOCATIONS AND <br /> AND OCCUPANCY GUIDE", IN APPENDIX B. www.gectenergycons-ultlng.com <br /> � O MATERIALS SHALL BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR AND <br /> O SHALL CONFORM TO THE PROVISIONS AS SET FORTH IN THE LATEST EDITION OF THE <br /> lb (2) STREET LIGHT CIRCUITS NOT OWNED BY SVP MUST BE INSTALLED TO MEET THE CALIFORNIA ELECTRICAL CODE, LATEST EDITION OF THE CALIFORNIA ENERGY CODE, AND THE <br /> O S S QUANTITY AS <br /> REQUIREMENTS OF SVP'S "JOINT TRENCH CONFIGURATIONS AND OCCUPANCY LATEST CALIFORNIA GREEN BUILDING CODE. oFESsi <br /> 0 �Q� �Nq� <br /> NEEDED GUIDE", AS IT APPLIES TO A SECOND ELECTRIC UTILITY. CONTACT SVP FOR THE aPN. ,P F <br /> 3" REQUIREMENTS AND REFER TO SVP'S "JOINT TRENCH CONFIGURATIONS AND �G" <br /> OCCUPANCY GUIDE" IN APPENDIX B. z <br /> 3" MIN. No. 21313 m <br /> 1-4" MIN. SAND BEDDING SHEET NOTES . ` Exp,093021 <br /> Oj ALL UNDERGROUND CONDUIT MUST BE PVC SCHEDULE 40 FOR UNDERGROUND TF OF CA��FO��\� <br /> CONDUIT WITH RIGID PVC COATED ON ALL ELBOWS TERMINATED TO BOTTOM OF SWITCHBOARD <br /> AND TRANSFORMER. <br /> 2 TYPICAL SERVICE TRENCH CLEARANCES DETAILS O ALL EXTERIOR CONDUIT EXPOSED TO WEATHER SHALL BE RIGID PVC COATED. <br /> E1 .1 NTS O3 PROVIDE 1 -5"C FOR PG&E SECONDARY FEEDER BETWEEN MSB AND PG&E TRANSFORMER. <br /> COORDINATE ROUTING WITH PG&E REPRESENTATIVE IN FIELD PRIOR TO COMMENCING ANY <br /> WORK. PROVIDE TRENCHING AND SPACING WITH OTHER UTILITIES PER LATEST PG&E <br /> GREENBOOK REFER TO 2/E1 .1 FOR DETAILS. ELECTRICAL CONTRACTOR SHALL PROVIDE CABLE <br /> PULL CALCULATIONS PRIOR TO COMMENCING WORKS. IF THE CALCULATED PULLING TENSION <br /> (TYP) 6 0 DD EXCEEDS THE CABLE CAPACITY, THE CONTRACTOR SHALL PROVIDE SPLICING/PULLBOX IN <br /> _ URB#GUTTER <br /> 0 ACCORDANCE WITH PG&E REQUIREMENTS WITHOUT ADDITIONAL COST TO THE CLIENT AND <br /> CONSULTANT. <br /> (E) DRIVEWAY Da PAmoPTRAVEL O Da <br /> APPROACH PATH OF TRAVEL ® FEEDER ROUTE SHOWN IS A DIAGRAMMATIC ONLY. ELECTRICAL CONTRACTOR TO COORDINATE <br /> SIDEWALK WITH PG&E SUBSTRUCTURE AND JOINT TRENCH DRAWINGS FOR THE REQUIREMENT. <br /> 30' <br /> PROPERTY LINE SIDEWALK <br /> zs�, TT @) ELECTRICAL CONTRACTOR TO ENSURE THAT THE CONDUIT ROUTE IS WELL COORDINATED WITH <br /> - 10' RIGhT of WAY DEDICATION <br /> �} . . . . . . . - - .Al—l0y ❑P 'PLANTER <br /> OTHER UTILITIES (GAS, DRAINAGE, POTABLE WATER ETC.) <br /> -Al-10y �a � � I <br /> �} �a P _ W W I O' RIGHT OF WAY DEDICATION. W 1967 5Q.P. <br /> . .`� U p�� ti� g ROUTE EXTERIOR LIGHTING CIRCUITS VIA DIMMING RELAY POWER PACK LOCATED NEAR PANEL <br /> , ' (E)PRICE SIGN "Al" AND PROGRAMMED ASTRONOMICAL TIMECLOCK. <br /> � PROVIDE 2#10,1#10 GROUND WIRE <br /> To REMAIN MINIMUM FOR TYPE "P" EXTERIOR LIGHTING. <br /> w W GREASE (N)DOME MATS <br /> (E)PRICE SIG INTERCEPTOR PER ACCESSIBLE STANDARDS <br /> W <br /> TO REMAIN LOCATION „_ CARWASh <br /> (N)DOME MATS i <br /> ENTRANCE <br /> ` Al-10x W Al-1Ox a <br /> " , PLANTER <br /> W s�sQ E <br /> AccesS._ <br /> z <br /> VACUUM of (TYP) 6 <br /> PROPOSED <br /> 20 ,2 <br /> w <br /> w (TYP) s -STORE / GAS TAHr VACUUM <br /> SHUT <br /> W j 4,985 56[. . — Al-19 P PARKING Al-10y <br /> It t � W <br /> 2 ." Al—10x W QP�� z VA€CDM511 ALL <br /> 7 S^ x <br /> FIRE RATED <br /> CLEAN AIR VACUU'V Si ALL � <br /> VEHICLE �- <br /> w <br /> C Un CLEAN AIR6 <br /> 23 j( VEHICLE CQ <br /> �m Al 1 Ox <br /> '0 O O / <br /> rL <br /> ° W L� <br /> 81I- <br /> 5 APN 104-037-010 <br /> 0 0 I— <br /> 24 <br /> )C GROUND <br /> � N R®� U <br /> QE.W <br /> 1 .09 AC. on G 5 <br /> STORAGE- ONTAINEI 4410 W <br /> w EXISTING H.C. PARKING5PACE5 2 <br /> 25 CAR UVAS N 3 REGULAR PARKING ING 5F CE5CE5 4 <br /> VACUUM PARKING SPACES:4 <br /> PARKING TO MAIN 4 PUEUNG PARKING 5PACE5: 18 <br /> TOTAL PARKING SPACES : 51 <br /> 2G W 4 <br /> , GUARD POST GUARD POST :GUARD POST <br /> I� I <br /> (TYP OF 1 2) (TYP OF 1 2) ;' (TYP OF 1 2) <br /> TRASH VALET DISPENSER TRASH VALET DISPENSER TRASH VALET DISPENSER EXTERIOR LIGHTING FIXTURE SCHEDULE <br /> MSB-3 P OF 9) (Tyr OF 9) YP OF 9) --uDI P EN 9) (TYP OF 9) DI P EN 9) <br /> 27 10x G <br /> 34' <br /> W CANOPY CANOPY CANOPY I <br /> COLUMN(TYPOFe) COLUMN(TYPOF9) COLUMN(TYFOF_ SYMBOLS FIXTURE DESCRIPTION MANUFACTURER'S CATALOG NO. LAMPS VOLT WATTS MOUNTING <br /> W ELECTRIC TYPE <br /> , VEHICLE , `° <br /> CHARGING J <br /> 60A <br /> STATION <br /> z w LITHONIA LIGHTING <br /> o POLE MOUNTED LED EXTERIOR LIGHTING POLE 0 <br /> zI t 24 W OP WITH 20 FEET POLE RSX1 LED P3 40K R3 HS LED 120 109.4 <br /> j — NEMA 3R) ;( i WITH LED DRIVER (0-10V DIMMING) OR APPROVED EQUAL <br /> MOUNTED <br /> 29 _ � o <br /> {'J -OLUMNN(TYP OF 9) COLUMNCANOFY <br /> OF 9) COLUMNr(TY`('1 W 0 > <br /> O <br /> 0 <br /> O <br /> 1 2 3 4 5 00 `� LU — <br /> ® DISPENSER DISPENSER CANOPY ® I;PUINS �, t OUTDOOR WALL SCONCE LED LIGHTING LITHONIA LIGHTING WALL n z N <br /> 30 ® TYP of 9) (TYP OF 9) GASOLINE P OF OW WDGE2 LED P3 40K 80CRI LED 120 22.6 J = Ln <br /> FIXTURES MOUNTED w <br /> 9 DISPENSERS 1 0 WITH LED DRIVER(0-10V DIMMING) VW U QU F- <br /> TRASH VALE TRASH VALE OR APPROVED EQUAL `L U w U <br /> z � <br /> ® (TYP OF 9) (TYP OF 9) W Z <br /> 3I <br /> L-ANTE o � Z It <br /> I o <br /> 5Q.F. 2LL <br /> 4' 24' i <br /> 32 t Al-10y O U <br /> CANOPY CANOPY CANOPY O <br /> W W W W W -I N(TYP OF 9) COLUMN(TYF OF 9) CO'.U',N;TYP,' W <br /> 33 W W' `' ,N)DISPENSER (N)DISPENSER (N)DISPENSER <br /> (Tl'P OF 9) (TYP OF 9) MT OF 9) <br /> W30 35•_3•• <br /> W W ® TPA511 VALET GUARD P05T TRASH VALE GUARD POST <br /> (TYP OF 9) (TYP OF 2) (TYP Or 9) (TYF OF 1 2) 'Y <br /> ® • • <br /> I <br /> (E) UTILITY POWER 94' <br /> INCOMING <br /> 29-8" <br /> } DATE <br /> v 03/05/2020 <br /> wQ <br /> 28' ' ° <br /> E a- SCALE <br /> w Q A5 SHOWN <br /> DRAWN <br /> GEA <br /> --- - JOB <br /> SHEET <br /> 1 ELECTRICAL SITE PLAN 1 2 3 4 5 <br /> E1 .1 1/16"=1 '-0" <br />