REVISIONS BY
<br /> WATER AND WASTE FIXTURE LOAD SUMMARY PLUMBING FIXTURE SCHEDULE
<br /> WATER SUPPLY ROUGH-IN
<br /> DRAINAGE TAG DESCRIPTION MFR MODEL REMARKS
<br /> TAG DESCRIPTION QTY COLD WATER HOT WATER WASTE VENT CW HW
<br /> WSFU TOTAL WSFU TOTAL DFU TOTAL ELONGATED FLUSHOMETER BOWL, VITREOUS CHINA, FLOOR MOUNT. ADA COMPLAINT
<br /> WC WATER CLOSET - FV 3 5.0 15.0 - - 4.0 12.0 WC WATER CLOSET SLOAN WETS-2000.103 4„ 2" 1-1/2" - TOILET SEAT "CHURCH" MODEL: 7650T, ELONGATED OPEN FRONT SEAT.
<br /> LV LAVATORY 3 1.0 3.0 0.8 2.25 1.0 3.0 FLUSH VALVE - "SLOAN" MODEL: GEM-2 116, 1.28GPF MANUAL FLUSHOMETER VALVE. ASSE 1037 COMPLIANT.
<br /> O 3-COMP. SINK 1 3.0 3.0 2.3 2.25 3.0 3.0 RAVENA, SEMI PEDESTAL, WALL HUNG, VITREOUS CHINA.
<br /> AMERICAN ,> »
<br /> O3 MOP SINK 2 3.0 6.0 2.3 4.50 3.0 6.0 LV LAVATORY 0268.444 2 2 1/2 1/2 FAUCET - AMERICAN STANDARD MODEL:6114.116.002, MONTEREY SINGLE CONTROL CENTERSET,CAST BRASS BODY, METAL POP UP DRAIN,
<br /> STANDARD 0.5 GPM VANDAL RESISTANT, PRESSURE COMPENSATING MULTI LAMINAR SPRAY. PROVIDE THERMOSTATIC MIXING VALVE "WATTS' MODEL
<br /> < HAND SINK 1 1.0 1.0 0.8 0.8 2.0 2.0 LFMMV-UT-M1 (OR APPROVED EQUAL). ASSE 1070 COMPLIANT.
<br /> < ICEMAKER MACHINE 1 1.0 1.0 - - 1.0 1.0 O 3-COMPARTMENT SINK ADVANCE FCV3-1620-RL 3» _ 3/4" 3/4" THREE COMPARTMENT SINK. 16" X 20" X 14" TUBS WITH TWO 18" DRAIN BOARDS, 16 GA. STAINLESS STEEL.1
<br /> _ DRINK DISPENSERTABCO X FAUCET - "T&S" MODEL: B-0133-ADF12-B, SPLASH MOUNT FAUCET WITH 12" SWING NOZZLE, PRE-RINSE FAUCET WITH WALL BRACKET, 1.15
<br /> MACHINES STUB-OUT 1 3.0 3.0 - - 3.0 3.0 SPRAY VALVE.
<br /> WHB, RHB HOSE BIB 1 2.5 2.5 - - - - FLOOR MOUNTED, 20" x 16" x 6", GAUGE 16, 300 SERIES STAINLESS STEEL.
<br /> O3 MOP SINK ELKAY FLR-1X 3" 1-1/2" 3/4" 3/4" FAUCET - "KROWNE" MODEL: 16-127, KROWNE ROYAL SERIES SERVICE FAUCET, SPLASH MOUNT, 8" CENTERS, 6-1/2" LONG HEAVY CAST FESS/0 ALD
<br /> WHB, RHB ADDITONAL HOSE BIB 4 1.0 4.0 - - - - SPOUT WITH BAIL HOOK & HOSE THREAD, BRACKET CAN MOUNT ABOVE OR BELOW, VACUUM BREAKER, ROUGH BRASS, LOW LEAD, NSF AND ���"
<br /> co
<br /> ASSE 1001 COMPLIANT, 2.0 GPM MAXIMUM FLOW RATE.
<br /> FD FLOOR DRAIN 4 - - - - 2.0 8.0 G I- M36488 m
<br /> PBHSW-14101 S PRO BOWL SINKS, WALL MOUNTED, 14"WX1 O"Lx5" DEEP BOWL, WITH SIDE SPLASHES. � Exp.09/30/21 A
<br /> FS FLOOR SINK 4 - - - - 4.0 16.0 O4 HAND SINK JOHN BOOS SLRX CL
<br /> 2„ 1-1/2" 1/2" 1/2"
<br /> FAUCET - FISHER MODEL: 62669, STAINLESS STEEL 4 BACKSPLASH ADJUSTABLE WALL FAUCET WITH SWIVEL GOOSENECK SPOUT.
<br /> TOTAL FIXTURE UNIT: 38.5 9.75 54.0
<br /> WH DOMESTIC WATER HEATER AOSMITH DEN52 1" - 1" 1" DURA POWER, COMMERCIAL ELECTRIC WATER HEATER, 50 GALLONS STORAGE CAPACITY, 51GPH RECOVERY AT 80°F RISE, 2 ELEMENTS OF OF CA\-
<br /> ESTIMATED GPM: 46.0 8.0 - 5KW EACH SIMUTANEOUS OPERATION WITH A TOTAL POWER OF 1OKW, 208V, 3PHASE.
<br /> WH DOMESTIC WATER HEATER AOSMITH DEL20 1" - 1" 1" DURA POWER, COMMERCIAL ELECTRIC WATER HEATER, 20 GALLONS STORAGE CAPACITY, 20 GPH RECOVERY AT 80°F RISE, SINGLE ELEMENT
<br /> NOTES: 2 OF 4KW EACH SIMUTANEOUS OPERATION WITH A TOTAL POWER OF 4.0 KW, 208V, 3PHASE.
<br /> 1. WATER SUPPLY FIXTURE UNITS BASED UPON APPENDIX A, TABLE A103.1, 2019 CALIFORNIA PLUMBING CODE. MAX PRESSURE = 150 PSI TANK VOLUME = 3.5 GAL. MAX. ACCEPTANCE VOLUME = 2.3 GAL. ASME SECTION VIII CONSTRUCTION; W cj
<br /> 2. DRAINAGE FIXTURE UNITS BASED UPON CHAPTER 7, TABLE 702.1, 2019 CALIFORNIA PLUMBING CODE. EXPANSION TANK WATTS DETA-5 - - 1/2" -
<br /> i 2 FIXED BLADDER TYPE, PRE CHARGE TO 40 PSI. w.
<br /> Pou POINT OF USE WATERo
<br /> HEATER ECOSMART POU3.5 - - 1/2" 1/2" ELECTRIC TANKLESS WATER HEATER, 0.5 GPM @47.8°F RISE, 3.5KW, 120 VOLTS, 40.0 AMPS. J W
<br /> ENCASED MODERATE CLIMATE WALL HYDRANT FOR NARROW WALL INSTALLATION. COMPLETE WITH BRONZE BODY, ALL BRONZE INTERIOR �' p Q�
<br /> HYDRAULIC CALCULATIONWHB WALL HOSEBIB ZURN Z1350-RK-VB - - 3/4" - FEMALE RNLET AND 3/4ABLE E[19]AT WMALE RHOSE CONNECTION STANDARD, SCREWDRIVER OPERATED OADJUSTABLE EP VALVE IN SSTAINLESS S UPPLY, KEY OELRBOX DFURNISHED WITHEHINGED3COVER] IP
<br /> DESCRIPTION UNITS REMARKS CYLINDER LOCK AND "WATER" STAMPED ON COVER. QZ qj
<br /> CONTRACTOR TO VERIFY ACTUAL EXPOSED, LEAD-FREE, NON-FREEZE ROOF HYDRANT. HYDRANT FEATURES A DURA-COATED CAST IRON HEAD AND LIFT HANDLE WITH LOCK Z °m
<br /> (A). PRESSURE AT STUB-OUT (psi) 65.0 PRESSURE AT SITE. OPTION, GALVANIZED STEEL CASING, BRONZE AND STAINLESS STEEL INTERIOR COMPONENTS, 3/4" [19] INLET CONNECTION WITH 1/8" [3] W
<br /> RHB ROOF HOSEBIB ZURN Z1388XL-VB - - 3/4 - TAPPED DRAIN PORT ON HOUSING, AND 3/4" [19] MALE HOSE CONNECTION. COMPLETE WITH DURA-COATED CAST IRON ROOF SUPPORT 3
<br /> IN
<br /> (B). LOSS ACROSS METER (psi) 4.6 (E)1-1/2 WATER METER SLEEVE WITH WIDE ANCHORING FLANGE AND CLAMP COLLAR.
<br /> (C). PRESSURE AFTER PRV (psi) 0.0 BFP BACKFLOW PREVENTER WATTS LF009 - - 1-1/2" - LEAD FREE, ASSE 1013 COMPLIANT, REDUCED PRESSURE ZONE ASSEMBLY.
<br /> (D). LOSS ACROSS BACK FLOW PREVENTER (psi) 13.0 WATS LF009, 1-1/2" SIZE TP TRAP PRIMER MIFAB M-500 - - 1/2" _ PRESSURE DROP ACTIVATED, BRASS CONSTRUCTION. PROVIDE WITH MULTIPLE DISTRIBUTION UNIT (IF APPLICABLE), PROVIDE WITH APPROVED
<br /> ACCESS PANEL.
<br /> z
<br /> (E). ELEVATION LOSS (psi): STATIC HEIGHT (ft): 20 8.7 STATIC HEIGHT(ft) x 0.433(psi/ft) FS FLOOR SINK ZURN FD2375 2" 1-1/2" - _ ENAMELED CAST IRON FLOOR SINK 12"x12"x6" DEPTH WITH ACID-RESISTANT COATING AND AN ABS ANTI-SPLASH DOME STRAINER. REFER
<br /> ALLOWANCE FOR WATER CLOSET TO LAYOUT FOR GRATING REQUIREMENT.
<br /> (F). RESIDUAL PRESSURE REQUIRED (psi) 25.0 FLUSH VALVE OPTION. FD FLOOR DRAIN ZURN Z415B 2" 1-1/2" - - NO-HUB, DURA-COATED CAST IRON BODY, NICKEL BRONZE TOP TYPE 'B' STRAINER WITH TRAP PRIMER CONNECTION. Ov
<br /> (G). DEVELOPED LENGTH OF BUILDING PIPING (ft): PIPE LENGTH (ft): 260 390 PIPE LENGTH (ft) x 1.5(FITTINGS RD ROOF DRAIN ZURN RD2130-NH4 2" - - - NO-HUB, DURA-COATED CAST IRON BODY, COMBINATION ROOF DRAIN AND OVERFLOW.
<br /> LOSSES)
<br /> (H). PRESSURE AVAILABLE FOR FRICTION LOSSES IN BUILDING PIPING (psi) 13.7 A - (B+D+E+F) WCO WALL CLEAN-OUT ZURN ZS1468 SEE RISER - - - ROUND STAINLESS STEEL WALL ACCESS COVER COMPLETE WITH SECURING SCREW AND BRONZE RAISED HEX HEAD PLUG.
<br /> (I). ALLOWABLE LOSSES PER 10OFT OF BUILDING PIPING (psi) 3.5 (H/G)xlOO, USE; = 3 PSI FCO FLOOR CLEAN-OUT ZURN Z1400 SEE LAYOUT - _ - ADJUSTABLE FLOOR CLEANOUT, DURA-COATED CAST IRON BODY WITH GAS AND WATERTIGHT ABS TAPERED THREAD PLUG AND
<br /> ROUNDSCORIATED CAST IRON HEAVY-DUTY SECURED TOP ADJUSTABLE TO FINISHED FLOOR.
<br /> COTG CLEAN OUT TO GRADE ZURN CO-2410 SEE LAYOUT - - CLEAN OUT BODY AND PLUG.
<br /> PRECISION
<br /> WATER PIPE SIZE TABLE WHA WATER HAMMER ARRESTER PLUMBING - - - SEE LAYOUT WATER HAMMER ARRESTER (PER PDI WH2O1-94 SIZING TABLE) OR EQUAL APPROVED. ASSE 1010 COMPLIANT.
<br /> PRODUCTS
<br /> COLD WATER HOT WATER NOTES: z
<br /> PIPE SIZE (VELOCITY =< 8FT/S) (VELOCITY =< 5FT/S) 1. CONTRACTOR MAY SUBSTITUTE APPROVED EQUIVALENTS FOR SPECIFIED FIXTURES WITH OWNER'S AND ENGINEER'S APPROVAL. PROVIDED ALL THE REQUIREMENTS OF THE APPLICABLE CODE ARE MET.
<br /> 2. CONTRACTOR TO SUBMIT CUT-SHEETS OF ALL FIXTURES FOR OWNER'S REVIEW AND APPROVAL PRIOR TO INSTALLATION. LQ
<br /> GPM FLUSH TANK FIXTURE UNIT FLUSH VALVE FIXTURE UNIT GPM FLUSH TANK FIXTURE UNIT :�i W
<br /> 1/2" 2 1 - 2 1 D
<br /> 3/4" 5 5 - 5 5 WATER HEATER - 1 WATER HEATER - 2
<br /> 1" 9 12 - 9 12 GPH TOTAL GPH GPH TOTAL GPH
<br /> 1-1/4" 16 23 - 16 23 TAG DESCRIPTION QTY PER PER TAG DESCRIPTION QTY PER PER
<br /> FIXTURE FIXTURE FIXTURE FIXTURE
<br /> 1-1/2" 25 42 8 25 42
<br /> LV HANDSINK 1 2.0 2.0 LV LAVATORY 2 5.0 10.0
<br /> 2" 51 130 50 48 120
<br /> O1 3-COMPARTMENT SINK 1 45.0 45.0 <3> MOP SINK 1 15.0 15.0
<br /> 2-1/2" 90 324 193 74 247
<br /> O3 MOP SINK 1 15.0 15.0 POSSIBLE MAXIMUM DEMAND (GPH) 25.0
<br /> 3" 142 596 504 106 412 POSSIBLE MAXIMUM DEMAND (GPH) 62.0 DEMAND FACTOR 0.8
<br /> DESIGN PRESSURE PER 10OFT OF PIPE = 3 PSI
<br /> DEMAND FACTOR 0.8 STORAGE FACTOR 1.0
<br /> z
<br /> STORAGE FACTOR 1.0 RECOVERY(GPH) 20.0 O
<br /> BUILDING PIPE MATERIAL SCHEDULE RECOVERY(GPH) 49.6 SELECTED STORAGE(Gal.) 20.0 G /
<br /> 0 J SELECTED STORAGE(Gal.) 50.0 ADJUSTED RECOVERY(GPH) 20.0 w g >
<br /> J Q D:f w w w w J o � o ADJUSTED RECOVERY(GPH) 49.3 TEMPERATURE RISE (°F) 80.0 W N
<br /> a a_ a Li
<br /> z
<br /> D > 0 z 0 N a_ 0 0 0 N J o f TEMPERATURE RISE (°F) 80.0 MINIMUM WATER HEATER EFFICIENCY 0.98 w J _j G)
<br /> SERVICE LOCATION = °�° 0 Q x J Y Y o N o SLOPE REMARKS z Q F- Q
<br /> con =j w w w J v Q v MINIMUM WATER HEATER EFFICIENCY 0.98 MINIMUM INPUT (KW) 4.0 z W U
<br /> p d d a >
<br /> o z � O
<br /> Z m N MINIMUM INPUT (KW) 9.8
<br /> 0 _j � U
<br /> ABOVE GRADE 1/32" PER 1' ASTM B88WITH WROUGHT COPPER FITTINGS. O
<br /> WATER ASTM B88, FACTORY INSULATED, WITH WROUGHT COPPER BRAZED JOINT z D
<br /> BELOW GRADE 1/32" PER 1' FITTINGS. < j
<br /> ABOVE GRADE 1/4" PER 1' ASTM A888, ALL FITTINGS SHALL BE AS PER CPC. _
<br /> SEWER AND W
<br /> VENT BELOW GRADE 0 1/4" PER 1' CONFORM TO ASTMD 2321-2000, ALL FITTINGS SHALL BE AS PER CPC.
<br /> INDIRECT BELOW GRADE 0 1/4" PER 1'
<br /> WASTE
<br /> INSIDE • 1/4" PER 15'
<br /> NATURAL OUTSIDE • 1/4" PER 15'
<br /> GAS
<br /> BELOW GRADE 1/4" PER 15' WITH FACTORY INSTALLED COATING LISTED FOR DIRECT BURIAL. DATE 03/05/2020
<br /> CONDENSATE BELOW GRADE 1/8" PER 1'
<br /> STORM DRAIN ABOVE GRADE 1/4" PER 1ASTMD 2321-2000 SCALE
<br /> 5h0WN
<br /> BELOW GRADE 1/4" PER 1' ASTMD 2321-2000
<br /> DRAWN
<br /> GEA
<br /> JOB
<br /> SKEET
<br /> J L FO •
<br />
|