Laserfiche WebLink
REV 1510NS BY <br /> GENERAL NOTES <br /> A. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL PIPING <br /> AND UTILITIES PRIOR TO START OF WORK. IN THE EVENT OF ANY <br /> 11 $ o°oo°°°°°°oo°°°°°°000°°°o° DISCREPANCIES OR POTENTIAL CONFLICTS, NOTIFY THE ARCHITECT <br /> °O°°°°°°°°°°°0000000000000000000000000AND ENGINEER IN WRITING PRIOR TO START OF WORK. <br /> ° <br /> °°°°°°°°°°°°° <br /> 0000000000000 <br /> °°°°°1 0°°°° B. ALL PIPING LOCATIONS ARE DIAGRAMMATIC. CONTRACTOR SHALL <br /> NORTH EGRESS <br /> E°4gAB;FHERS El <br /> El <br /> po <br /> QC�ci-c- 10 COORDINATE WITH ALL TRADES AND OWNER'S REPRESENTATIVE AND <br /> STAIR UP IOG VERIFY EXACT ROUTING PRIOR TO START OF WORK. <br /> 1-1/2"CW 1 GO sQ. F. 6 2 I 5 /RESTROOM <br /> T/A 20 19 1� 17 15 15 14 13 12 11 10 0 3 7 .; 5 4 3 2 1 FD C. HOT WATER PIPING SHALL BE INSULATED AND IN COMPLIANCE <br /> WITH CEC TABLE 120.3-A. <br /> I g <br /> WHI I D. PIPE PENETRATIONS OF FIRE RATED WALL, FLOOR & CEILING SHALL <br /> L BE PROTECTED AS PER CBC 714.3. <br /> - --3/4"CW-_ 2�C 2 <br /> 2 E. DOMESTIC WATER PIPING SHALL BE AT CEILING SPACE OR <br /> 3/4"HW WHg HIGH LEVEL. UNLESS OTHERWISE NOTED. <br /> FI-04 I ET WH 3 ��'' TP <br /> CASHIER N I 3 2 2 F. INSTALL ASSE 1010 COMPLIANT WATER HAMMER ARRESTERS <br /> AREA \ I 11 ON LOCATIONS INDICATED IN LAYOUT. <br /> FESS/0 <br /> METAL I 6 V °� �`` �� A�D�cAG`F2c <br /> 30 x 4 72�� LAP c� � M36488 � m <br /> GONDOLAS g SHEET NOTES w � m <br /> - - - M ETA- - --2"C W- - - - - - - - - - �';C - I Exp.09/30/21 A <br /> GONDOLAS <br /> SALES ATEA 2 /R 0 sQoo F <br /> 2,208 SQ. I 1 '' CLEAR C <br /> cWF CAS <br /> SOFFIT <br /> 10 O1 INSTALL REDUCE PRESSURE ZONE ASSEMBLY BACK FLOW <br /> WHB BFP o°o°o°° ° °°°°° PREVENTER. SEE PO.2 PLUMBING SCHEDULE FOR <br /> FE-31 <br /> GAS TANKS 000000000000000 SPECIFICATION. <br /> °o°o°o°o°o°o°o° <br /> SHUT OFF 000000000000000 o <br /> Lo G <br /> 000000000000000 O2 3/4"CW DOWN IN WALL FOR RECESSED WALL HYDRANT. Q <br /> WALK-IN G cv 000000000000000 F 75 <br /> _ ti <br /> METAL 000000000000000 a m J , <br /> FREEZER I ° ° ° ° ° ° ° O3 1 CW AND 1 HW PIPE TO WATER HEATER. PROVIDE <br /> o°o°o°o°o°o°o°o o I <br /> 82 sQ. F. GONDOLAS °o°o°o°o°o°o°o° <br /> 2 SEE SITE PLAN, P2.0 I o°o°o°o°o°o°o°o EXPANSION TANK AND ALL NECESSARY ACCESSORIES FOR <br /> FOR CONTINUATION- WATER HEATER SYSTEM. INSTALL AS PER MANUFACTURERS O <br /> 3 \ RECOMMENDATION. <br /> 30 6a DOOR <br /> 104-2 O4 1/2„CW AND 1/2„HW PIPE RUN THROUGH WALL WITH W w <br /> F I T ISOLATION VALVE. Z <br /> o O 3 <br /> O5 3/4"CW AND 3/4"HW PIPE RUN THROUGH WALL WITH 3 <br /> ISOLATION VALVE. °� 3 <br /> O ENTRY © 3/4"CW AND 3/4"HW PIPE RUN THROUGH WALL WITH <br /> ISOLATION VALVE. INSTALL FAUCET WITH INTEGRAL ASSE 1001 <br /> FIRE RATED 2 COMPLIANT VACUUM BREAKER. <br /> WALL BETWEEN z <br /> CAR WASH G3/4`CW 8 I 70 1/2"CW PIPE RUN THROUGH WALL WITH ISOLATION VALVE <br /> T/A FOR ICE MAKER. SHALL HAVE BUILT IN BACKFLOW U <br /> 9 I P PREVENTER. INSTALL SUITABLE WATER FILTER AS 0 <br /> O4 --3/4"CW-- OFFIT RECOMMENDED BY THE MANUFACTURER. <br /> ENTRANCE WALK-IN 0 I �' ® 3/4"CW PIPE RUN THROUGH WALL WITH ISOLATION VALVE. <br /> COOLER I COLD WATER ONLY DEDICATED STUB-OUT FOR DRINK <br /> 343 SQ. F. <br /> DISPENSERS. SHALL BE CAPPED PIPE PRIOR TO <br /> INSTALLATION. <br /> 12 <br /> AND HN <br /> 13 I O ISOLATION VALVE. INSTALL RTHROUGH I <br /> ALL ASSEA <br /> 1070 COMPLIANT <br /> THERMOSTATIC MIXING VALVE. <br /> 14 <br /> ID-1 10 1-1/2"CW PIPE RUN THROUGH WALL WITH ISOLATION VALVE O 0 <br /> 15 I FOR FLUSH VALVE WATER CLOSET. 0 <br /> J Q <br /> 6 i 1 1 1/2"CW PIPE RUN THROUGH WALL WITH ISOLATION VALVE LL_ —� <br /> FOR TRAP PRIMER. TRAP PRIMER PROTECTION FOR FLOOR <br /> DRAIN AND INDIRECT RECEPTOR. SUPPLY PIPE SHALL BE <br /> 17 <br /> HARD DRAWN CONTINUOUS SLOPE. PROVIDE WITH MULTIPLE v l W <br /> DISTRIBUTION UNIT (IF APPLICABLE). PROVIDE WITH <br /> 18 I APPROVED ACCESS PANEL. LL_ <br /> 19 <br /> I <br /> 20 <br /> zl I <br /> 22 9 <br /> I <br /> (E) CAR WASH <br /> 2 PORTABLE FIR <br /> EXTINGUISHERS <br /> \ 48"A.F.F. <br /> A <br /> (E)CAR WASH-, I 0 51MACY11NE5 p 0 <br /> �\ OFFICE <br /> 0 \Tp 69 SQ. F. <br /> cz <br /> \\ I <br /> E)CAR WASN <br /> 11 Lu O O <br /> ELECTRICAL O N <br /> SUB PANEL T,� TP 3/4"CW = z Ln <br /> 10 3/4"HW v U <br /> Q <br /> STORAGE z w U <br /> QD <br /> 437 5Q. F. 3 5 > Z z <br /> 1 , o <br /> `" UL <br /> FD <br /> 1-1/2 O U <br /> %e 1"HW z <br /> Q � O <br /> O F I44 v J <br /> AQ 4 >Q <br /> f_ WHB <br /> WHA <br /> 2 <br /> 3 ET WH <br /> L I B B <br /> II 7 <br /> RO F <br /> 10 <br /> ACC 551 ELECTRICAL <br /> F. e ROOM <br /> 2 <br /> DATE <br /> EXIT 03/05/2020 <br /> L) SCALE <br /> AS 5110WN <br /> DRAWN <br /> GEA <br /> JOB <br /> 1 ST FLOOR PLAN — WATER LAYOUT <br /> SKEET <br /> P2. 1 3/16" = 1 '-0" P 2 ,0 <br />