Laserfiche WebLink
REVISIONS BY <br /> GENERAL NOTES <br /> A. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL PIPING <br /> AND UTILITIES PRIOR TO START OF WORK. IN THE EVENT OF ANY <br /> DISCREPANCIES OR POTENTIAL CONFLICTS, NOTIFY THE ARCHITECT <br /> AND ENGINEER IN WRITING PRIOR TO START OF WORK. <br /> NORTH 4 B. ALL PIPING LOCATIONS ARE DIAGRAMMATIC. CONTRACTOR SHALL <br /> COORDINATE WITH ALL TRADES AND OWNER'S REPRESENTATIVE AND <br /> C� 3 0 LV ���� 2 'p VERIFY EXACT ROUTING PRIOR TO START OF WORK. <br /> t <br /> 5 zo 9 .8 6 5 4 3 o C. HOT WATER PIPING SHALL BE INSULATED AND IN COMPLIANCE <br /> WITH CEC TABLE 120.3—A. <br /> — ST�861b9 1-1/2"CW <br /> D. PIPE PENETRATIONS OF FIRE RATED WALL, FLOOR & CEILING SHALL <br /> r C W F/B 2 O BE PROTECTED AS PER CBC 714.3. <br /> w CL. <br /> Do 1 44 5Q. F. E. DOMESTIC WATER PIPING SHALL BE AT CEILING SPACE OR <br /> r HIGH LEVEL. UNLESS OTHERWISE NOTED. <br /> 'PORTABLE FIRE <br /> @- EXTINGUI511ER5 <br /> 000� 48"A.F.F. F. INSTALL ASSE 1010 COMPLIANT WATER HAMMER ARRESTERS <br /> ON LOCATIONS INDICATED IN LAYOUT. <br /> Ga �o <br /> 102-I Q�pFESS/0N <br /> O Al q! <br /> r/ SOFFIT D�cAG F2 <br /> Exrw�Bs ERscM36488 m <br /> 48"A.F.F. (p SOFFIT G SHEET NOTES w <br /> Exp.09/30/21 A <br /> 201 Q <br /> i OFFICEF CAS <br /> 917 5Q. F. O1 1-1/2"CW PIPE RUN THROUGH WALL WITH ISOLATION VALVE <br /> FOR FLUSH VALVE WATER CLOSET. <br /> O2 1/2"CW PIPE RUN THROUGH WALL WITH ISOLATION VALVE <br /> 3/4"CW LAVATORY WATER SUPPLY. F m <br /> T/A 2 0 <br /> STORAGE O3 POINT OF USE ELECTRIC TANKLESS WATER HEATER. INSTALL "a j W Lq <br /> 205 SQ. F. AS PER MANUFACTURER'S RECOMMENDATION. <br /> 0 4 INSTALL ASSE 1070 COMPLIANT THERMOSTATIC MIXING VALVE. — ~ <br /> E � W <br /> O5 1/2"CW PIPE RUN THROUGH WALL WITH ISOLATION VALVE W ti <br /> SOFFIT FOR TRAP PRIMER. TRAP PRIMER PROTECTION FOR FLOOR Z <br /> DRAIN AND INDIRECT RECEPTOR. SUPPLY PIPE SHALL BE W 3 <br /> HARD DRAWN CONTINUOUS SLOPE. PROVIDE WITH MULTIPLE 3 <br /> zt <br /> DISTRIBUTION UNIT (IF APPLICABLE). PROVIDE WITH <br /> APPROVED ACCESS PANEL. <br /> SOFFIT <br /> z <br /> Q <br /> 3/4"CW <br /> T/A G z0 <br /> 0 � <br /> 0 0 <br /> �Q <br /> J <br /> zLL— <br /> CL/ <br /> 0 <br /> U Q <br /> W <br /> (E) CAR WA511 <br /> z <br /> O <br /> R/ <br /> � <br /> 0 > O <br /> L1J z LN <br /> w Z _j <br /> U (- <br /> w Q <br /> Lu <br /> QD U <br /> zz z � z <br /> zw 0 <br /> O � <br /> 0 U <br /> zQ � o <br /> VWJ <br /> ROO F <br /> CCES <br /> DATE <br /> 03/05/2020 <br /> SCALE <br /> AS SHOWN <br /> DRAWN <br /> GEA <br /> JOB <br /> 2ND FLOOR PLAN - WATER LAYOUT <br /> SHEET <br /> P2.2 3/16" = 1 '-0" F) 2 ,0 2 <br />