Laserfiche WebLink
" z SAN JOAQUIN a <br /> '°mac° Environmental Health Department <br /> Qi '- ! <br /> � <br /> N' Linda Turkatte, REHS , Director <br /> g <br /> Greatness rows here .UFOR��P 9 Kasey Foley, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> � Jeff Carruesco , REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> { - J Muniappa Naidu , REHS <br /> December 13 , 2017 <br /> Alexia Inigues <br /> Barghausen Consulting Engineers , Inc . Sent by Certified Mail <br /> 18215 72nd Avenue South <br /> Kent , WA , 98032 <br /> Re : ARCO Fac . No . 7049 SR0078236 <br /> 800 East Kettleman Lane <br /> Lodi , CA . 95240 <br /> The permit application to install an underground storage tank ( UST) system at the above address was <br /> received by the San Joaquin County Environmental Health Department ( EHD ) on October 6 , 2017 . In <br /> order for your application review to continue , please provide the following additional information (three <br /> copies each ) and address the following comments : <br /> 1 ) Page 3 of the Application for Underground Storage Tank Installation Permit : Indicate the <br /> Contractor' s name , phone , address , license number, hazardous waste certificate , worker' s <br /> comp number, proposed install date , and the plan reviewer' s name and date . <br /> 2 ) Provide UPCF Underground Storage Tanks - Facility form (A) with facility information and <br /> property owner information in a legible format . <br /> 3 ) Form B tank lists AN alarm and flapper, however, flapper only is identified on the permit <br /> application . Clarify and resubmit . <br /> 4 ) Provide current contractor' s training certifications for installation and testing of all proposed <br /> UST equipment/components , including but not limited to : tanks , sumps , sensors , monitoring <br /> panel , leak detectors , piping , spill containment , and penetrations . <br /> 5 ) Provide a drawing /map indicating the locations of all water wells , septic systems , and storm <br /> drains . <br /> 6 ) Submit a work plan for enhanced leak detection ( ELD ) testing , to be conducted by a properly <br /> licensed individual . <br /> 7 ) Submit manufacturers ' cut sheets for tanks , piping , and equipment . (e . g . Tank cut sheet for <br /> specific tank model used , electronic leak detector, flex connectors , under dispenser <br /> containment , vent transition sumps , fill sumps , all product penetrations with the correct model <br /> number, brine , secondary pipe sensor , spill containers , and tank interstitial sensor) . Cut sheets <br /> for items missing on the install plan pages M . 5 . 3 . 01 and M . 5 . 3 . 02 are #28 , 41 , 51 - 54 , 72 , 73 , <br /> 811 821 85 , 90 ( indicate which specific dispenser island ) , 102 , 104 ( be specific) , 105 - 111 , 150 , <br /> 153 , 163 , 166 , 171 - 176 , 200 , 204 , 205 , 207 , 208 , 211 , 212 , and for items # 143 , 146 , 152 , 156 , <br /> 161 , 164 the correct model number should be indicate and also provide cut sheets if not <br /> available . Please provide manufacturer' s cut sheets for parts listed on G . 0 . 5 of the install plans . <br /> 8 ) Provide UL Listing/third party testing approval for all UST system equipment . <br /> 9 ) Provide the accurate overfill prevention model number and cut sheet . Provide drop tube <br /> measurement calculations . <br /> 10 ) Sheet M . 5 . 3 . 02 lists two liquid sensor options ( 208 and 323 position sensitive) for sump <br /> monitoring , one should be selected . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468,F, 34201 F 209 464 -0138 1 www. sjcehd . com <br />