My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
INSTALL_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 1:30:08 PM
Creation date
8/25/2020 4:25:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM(Page 4 of 5 <br /> VIII. MONITORING SYSTEM AND PROGRAMMING <br /> This section must be completed If a monitoring panel is used to perform leak detection monitoring, Y N NA <br /> Are the visual and audible alarms operational? a ❑ ❑ <br /> Were all sensors visually Inspected for kinks and breaks in the cables and for residual buildup to ensure that floats move freely, <br /> functionally tested,and confirmed o rallonal7 0 ❑ ❑ <br /> Were all sensors Installed at lowest point of secondary containment and positioned so that other equipment will not Interfere with <br /> their proper operation? ❑ ❑ <br /> Was monitoring system set-up reviewed to ensure proper settings? ❑X ❑ ❑ <br /> Was the monitoring panel's backup battery visually Inspected,functionally tested,and confirmed operational? Q ❑ ❑ <br /> Does the flow of fuel stop at the dispenser if a leak Is detected in the under-dispenser containment? ❑X ❑ ❑ <br /> Does the turbine automatically shut down if the piping secondary containment monitoring system faits to operate or Is electrically <br /> dlsconnected7 ❑X ❑ ❑ <br /> Does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak? ® ❑ ❑ <br /> Which sensors initiate positive shut down? (Cherk all that apply.) ❑X Sump X❑Under-Dispenser Containment <br /> If alarms are relayed to a remote monitoring station,Is an communications equipment(e.g.,modem)operational? 0 ❑ ❑ <br /> For any answer of"N"above,describe In Section IX how and when these deficiencies were or will be corrected. <br /> IX. COMMENTS <br /> No fuel in tanks to run turbines <br /> X. IN-TANK GAUGING TESTING <br /> ❑Check this box If tank gauging is used only for Inventory control.(Do not complete this section.) <br /> ❑Check this box if NO lank gauging equipment Is Installed.(Do not complete this section.) Y N NA <br /> This section must be completed if In-tank gauging Is used to perform leak detection monitoring. <br /> Has all input wiring been inspected for kinks and breaks in the cables and for proper entry and termination,including testing for El ❑ <br /> round faults? <br /> Were all In-tank gauging probes visually Inspected for damage and residue buildup to ensure that floats move freely,functionally ❑X ❑ ❑ <br /> tested and confirmed operational? <br /> Was accuracy of system's product level readings tested? ❑X ❑ <br /> Was accuracy of system's water level readings tested? X ❑ ❑ <br /> Were all probes reinstalled properly? 0 I ❑ [] <br /> Were all Items on the equipment manufacturer's maintenance checklist completed? z I ❑ 0 <br /> For any answer of"N"above,describe in Section Xl how and when these deficiencies were or will be corrected. <br /> XI. COMMENTS <br /> Y=Yes,N=No,NA=Not Applicable <br />
The URL can be used to link to this page
Your browser does not support the video tag.