Laserfiche WebLink
Small Quantity Hazardous Waste Generator Inspection Report <br />Date: <br />August 27, 2018 <br /> Facility Address: <br /> 34 N VENTURA AVE, STOCKTON <br /> Facility Name: <br /> ASSOCIATED TRACTOR SERVICE INC <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 117 HSC 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on August 12, 2016 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by September 12, 2016. <br />This information has not been received resulting in a non-compliant status for this facility. An operator that receives <br />an inspection report shall have 30 days to submit a written response that includes a statement documenting <br />corrective actions taken or proposing corrective actions which will be taken. Ensure that a written response <br />documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />This is a Class II violation. <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste. <br />Dark, oily staining was observed on soil throughout the yard and on the ground in the shop. Facilities shall be <br />maintained and operated to minimize the possibility of a fire, explosion, or release of hazardous waste to air, soil, or <br />surface water which could threaten human health or the environment. Immediately clean all stained areas, and <br />manage according to Title 22 hazardous waste regulations. Submit a statement and supporting documentation <br />explaining how this waste was managed. <br />This is a repeat violation, Class II. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br />waste. <br />One white five gallon plastic bucket was observed containing oily saturated debris. All hazardous waste containers <br />shall be closed at all times except when adding or removing waste. Immediately close these containers and ensure <br />all hazardous waste containers are closed when not adding or removing waste. <br />This is a repeat violation, Class II. <br /> 505 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks. <br />The used oil tank in the yard was observd with a hazardous waste label missing the accumulation start date. All <br />hazardous waste tanks shall be marked with the words “Hazardous Waste” and the accumulation start date. <br />Immediately ensure that all hazardous waste tanks are marked with the required information. <br />This is a Class II violation. <br />Page 5 of 7 <br />FA0020337 PR0537094 SC001 08/27/2018 <br />EHD 22-01 Rev. 09/22/16 Small Quantity Hazardous Waste Generator OIR