My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2021 10:51:14 AM
Creation date
8/27/2020 2:37:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
Harney Lane 76
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x Environmental Health Department <br /> SANJUUII <br /> 6A� —COUNTY <br /> `c v Greatrxess grows here, <br /> Underground Storage Tank Program Compliance Review Report <br /> Facility Name and Address: Harney Lane 76, 141 E HARNEY LN, LODI 95240 <br /> #206 CCR 2712(i),2634(e) Failure to have a current UST Response Plan available on site <br /> OBSERVATIONS:OBSERVATION:An approved copy of the response plan was not available for inspection. <br /> REGULATION GUIDANCE:A copy of this plan shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Immediately locate and retain a copy on site. <br /> This is a Class II violation. <br /> #208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements <br /> OBSERVATIONS:OBSERVATION:The designated operator failed to document all the alarms on designated operator <br /> inspection report and failed to check that they were responded to appropriately. <br /> REGULATION GUIDANCE: During the inspection,the designated operator shall review the alarm history since the previous <br /> inspection, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm history <br /> with documentation taken in response to any alarms to the inspection report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of the <br /> required information on the reports. <br /> This is a Class II violation. <br /> #210 CCR 2715(c) Failure to provide initial training,train every 12 months,and have a trained employee present <br /> OBSERVATIONS:OBSERVATION:The designated operator employee training has not been completed. <br /> REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and maintenance <br /> of the UST system at least once every 12 months. The training shall be conducted before the individual performs the duties <br /> of a facility employees.The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and evaluating <br /> knowledge for responding to emergencies, leak detection, monitoring alarms, spills and overfills. At least one of the facility <br /> employees present during operating hours shall have current training. <br /> CORRECTIVE ACTION: Ensure that employees have been trained by the designated operator, maintain the list on site, and <br /> submit a copy of the training records to the EHD. <br /> This is a Class II violation. <br /> FA0024750 PR0543574 SCO21 11/25/2020 <br /> Rev.9/16/2020 Page 3 of 4 Underground Storage Tank Program Compliance Review Report <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.