My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
20
>
2300 - Underground Storage Tank Program
>
PR0231380
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2020 10:36:15 AM
Creation date
9/1/2020 10:28:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231380
PE
2361
FACILITY_ID
FA0000645
FACILITY_NAME
SHORT STOP FOOD MART
STREET_NUMBER
20
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04134015
CURRENT_STATUS
01
SITE_LOCATION
20 W TURNER RD # A
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited : Chapter 6 . 7, Health and Safety Code ; Chapter 16, Division 3 , Title 23 , California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility <br /> Name: SHORT STOP 76 Bldg. No. : <br /> Site <br /> Address: 20 W TURNER RD City: LODI Zip: 95240 <br /> Facility Contact <br /> Person: ALI Contact Phone No. : (209) 369-3697 <br /> Make/Model of Monitoring System : VEEDER ROOT TLS 360 Date of Testing/Servicing : 9-17-18 <br /> B . Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced : <br /> Tank ID : 87 Tank ID : 91 <br /> ® In-Tank Gauging Probe. Model : MAG 1 N In-Tank Gauging Probe. Model : MAG 1 <br /> N Annular Space or Vault Sensor. Model : 420 N Annular Space or Vault Sensor. Model : 420 <br /> N Piping Sump / Trench Sensor(s). Model : 208 N Piping Sump / Trench Sensor(s) , Model : 208 <br /> ❑ Fill Sump Sensor(s). Model : ❑ Fill Sump Sensor(s), Model : <br /> N Mechanical Line Leak Detector, Model : 99 LD 2000 N Mechanical Line Leak Detector. Model : 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model : ❑ Electronic Line Leak Detector. Model : <br /> N Tank Overfill / High- Level Sensor. Model : FLAPPER N Tank Overfill / High-Level Sensor, Model : FLAPPER <br /> ❑ Other (specify equipment type and model in Section E on Page 2). ❑ Other (specify equipment type and model in Section E on Page 2), <br /> Tank ID : DIESEL Tank ID : <br /> N In-Tank Gauging Probe. Model : MAG 1 ❑ In-Tank Gauging Probe. Model : <br /> N Annular Space or Vault Sensor. Model : 420 ❑ Annular Space or Vault Sensor. Model : <br /> N Piping Sump / Trench Sensor(s). Model : 208 ❑ Piping Sump / Trench Sensor(s). Model : <br /> ❑ Fill Sump Sensor(s). Model : ❑ Fill Sump Sensor(s), Model : <br /> N Mechanical Line Leak Detector. Model : FX1V ❑ Mechanical Line Leak Detector. Model : <br /> ❑ Electronic Line Leak Detector. Model : ❑ Electronic Line Leak Detector. Model : <br /> N Tank Overfill / High-Level Sensor. Model : FLAPPER ❑ Tank Overfill / High-Level Sensor. Model : <br /> ❑ Other (specify equipment type and model in Section E on Page 2). ❑ Other (specify equipment type and model in Section E on Page 2). <br /> DispenserlD : 1 -2 DispenserlD : 34 <br /> ❑ Dispenser Containment Sensor(s) . Model : ❑ Dispenser Containment Sensor(s). Model : <br /> N Shear Valve(s). N Shear Valve(s). <br /> N Dispenser Containment Float(s) and Chain(s). N Dispenser Containment Float(s) and Chain (s). <br /> Dispenser ID : 5-6 Dispenser ID : 7-8 <br /> ❑ Dispenser Containment Sensor(s) . Model : ❑ Dispenser Containment Sensor(s), Model : <br /> N Shear Valve(s). N Shear Valve(s). <br /> N Dispenser Containment Float(s) and Chain(s) . N Dispenser Containment Float(s) and Chain(s). <br /> Dispenser ID : Dispenser ID : <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model : Sensor(s) . Model : <br /> ❑ ShearValve(s). ❑ ShearValve(s) . <br /> ❑ Dispenser Containment Float(s) and Chain (s). ❑ Dispenser Containment Float(s) and Chain(s) . <br /> `If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br /> C . Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines . Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br /> copy of the report; (check all that apply) : ® System set-up ® Alarm history report <br /> Technician Name (print) : DAVE WINKLER Signature: ^ l <br /> Certification No. : 8883059-UT License No: 08- 1739 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br /> Testing Company Address : 416 2nd STREET GALT, CA 95632 Date of Testing/Servicing : 9-17-18 <br /> Monitoring System Certification Page 1 of 4 2/21 /07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.