COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
20
>
2300 - Underground Storage Tank Program
>
PR0231380
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2020 10:36:15 AM
Creation date
9/1/2020 10:28:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231380
PE
2361
FACILITY_ID
FA0000645
FACILITY_NAME
SHORT STOP FOOD MART
STREET_NUMBER
20
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04134015
CURRENT_STATUS
01
SITE_LOCATION
20 W TURNER RD # A
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed : 325.01 <br /> Complete the followingchecklist: <br /> ® Yes ❑ No* Is the audible alarm operational? <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br /> operation ? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station , is all communications equipment (e.g. , modem) operational ? <br /> ® N/A <br /> ® Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, <br /> ❑ N/A fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) ® Sumpfrrench <br /> Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ® Yes ; ❑ No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (Le. , no mechanical overfill prevention valve is <br /> ® N/A installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity <br /> does the alarm trigger? % <br /> ❑ Yes ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name <br /> and model for all replacement parts in Section E , below. <br /> ® Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ® Product; ElWater. If yes, describe causes in Section E, below. <br /> ❑ Yes ® No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br /> ❑ Yes ® No* Is all monitoring equipment operational per manufacturers specifications? <br /> * In Section E below, describe how and when these deficiencies were or will be corrected . <br /> E. Comments: <br /> Monitoring System Certification Page 2 of 4 2/21 /07 <br />