Laserfiche WebLink
S A N rJ O A Q U I N Environmental Health Department <br /> —COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SUPER STOP GAS& LIQUOR' 290 N MAIN ST, MANTECA April 29, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Current Financial responsibility documents have not been submitted to the EHD. Financial responsibility documents <br /> uploaded to CERS were last signed on January 29th, 2018. Current financial responsibility documents are required <br /> to be submitted annually. The operator was able to log into the California Environmental Reporting System (CERS) <br /> at http://cers.calepa.ca.gov/, and uploaded the required documents to correct this violation while the inspector was <br /> on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan list TLS350 as the model of <br /> the panel, however Gilbarco, EMC panel was observed during the field inspection. Furthermore the leak sensor <br /> manufacturer and leak sensor model for the UDCs was not listed in the monitoring plan. The monitoring plan must be <br /> uploaded to the California Environmental Reporting System (CERS). The operator logged into CERS, and made the <br /> necessary changes, and submitted for review by the EHD while the inspector was on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 110 CCR 2637(e), 2637(f) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test. <br /> Secondary containment testing was performed on 7/19/18 and a test report was submitted on 3/29/19, over 7 <br /> months late. A copy of the test report must be submitted within 30 days of the tests. Take all necessary <br /> precautions to ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a Class II violation. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, and leak detector testing,was performed on 4/2/18 and a test report was <br /> submitted on 7/2/18, 3 months late. A copy of the test report must be submitted within 30 days of the tests. Take <br /> all necessary precautions to ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a Class II violation. <br /> FA0003716 PR0231438 SCO01 04/2912019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />