My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082410
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12 (STATE ROUTE 12)
>
13550
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0082410
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:48:04 PM
Creation date
9/3/2020 2:37:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0082410
PE
4231
FACILITY_NAME
13550 HWY 12
STREET_NUMBER
13550
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05502002
ENTERED_DATE
7/31/2020 12:00:00 AM
SITE_LOCATION
13550 W HWY 12
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Joe Grindstone Association <br /> 13550 Highway 12, Lodi (SR0081813) Pa�.:e <br /> 4. The Service Agreement with Advanced Septic Service, LLC dated October 31, 2019 scheduled <br /> pumping frequency quarterly (April 1, June 1, August 1, October 1). However, the Plan cited 13 days <br /> between "Time to Pump" Pumping Events (see KSN Water System Calculation). Under Section 10.5: <br /> The system must be operated to prevent sewage overflow from the system at all times. <br /> And Section 10.8.5 <br /> The pumping frequency required to maintain the system at a level below the alarm set point <br /> Please provide additional information and relevant document that will meet these requirements. <br /> 5. Cut-sheet for the proposed alarm (Orenco 120 VAC Liquid Level Alarm Panels) has been provided, <br /> but there is no discussion how the alarm is to be set up. Section 10.5 of OWTS Standards requires: <br /> Both Audible and visual alarms are required: <br /> 10.5.1 The alarms must be set to signal at the "time-to-pump"and "exceeding reserve <br /> storage volume"levels <br /> 10.5.2 The audible and visual alarms must be located in an area 6that can be readily <br /> seen and heard, with battery power where electrical power is not available. <br /> Please provide additional information how the above requirements will be met. <br /> 6. Provide frequency and how the tank and alarms are to be monitored, and operational records are <br /> maintained per Section 10.10: <br /> Operational records must be maintained <br /> 7. In an email dated April 27, 2020, Department of Public Works requested additional information from <br /> KSN. Please be aware comments and agreement from Public Works is required before EHD can <br /> consider permitting installation of the tank in lieu of an OWTS. <br /> 8. If the tank is permitted in lieu of an OWTS, in addition to the installation permit, the facility will be <br /> placed on SJC inventory for biannual inspection, where an annual Operational Permit (Program <br /> Element 4242) is required per Section 10.11 <br /> Please submit additional information addressing the above items to EHD as soon as possible. If you have <br /> any questions please contact Jeffrey Wong, Lead Senior Registered Environmental Health Specialist, REHS, <br /> at jwong@sjgov.org or (209) 468-0335. <br /> Mic ael Kith, REHS <br /> Program Coordinator <br /> Nitrate Well 10/27/15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.