My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2021 11:15:13 AM
Creation date
9/8/2020 2:19:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J U A Q U I NEnvironmental Health Department <br /> � 1i11iZr� <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> EMILS LIQUOR & SPORTS SHOP 1405 CALIFORNIA ST, ESCALON May 29, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> The annular space sensor for the split(87 product/91 product/diesel product) tank had been going in and out of <br /> sensor out alarm since October 2018. The Designated operator stated "13 and L4 needs to be checked, going in <br /> and out of alarm".The underground storage tank system shall be operated to prevent unauthorized releases. <br /> Immediately addressed the L4 annular space sensor out in and out of alarm. <br /> This is a repeat violation, Class Il. <br /> 307 CCR 2631(g), 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br /> The 87 product, 91 product and diesel product split tank annular had been going in and out of alarm since October <br /> 2018, therefore, the tank is not monitored. The interstitial space shall be monitored with a monitoring system <br /> connected to an audible and visual alarm system. Immediately contact a properly licensed, trained, and certified <br /> contractor to addressed the failed component with a functional component(LG 113-x listed, if applicable) under <br /> permit and inspection of the EHD within one business day. <br /> This is a repeat violation, Class If. <br /> 309 CCR 2636(f)(1) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo box float and chain in the87 product in UDC 3/4 sump failed to stop the flow of product at the dispenser <br /> when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br /> product at the dispenser when it detects a leak. The service technician adjusted the chain(s) and verified <br /> functionality. <br /> This is a repeat violation, Class Il. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations, title 23 division <br /> 3, chapter 16 section 2635(c)(2) shall test overfill prevention equipment once by October 13th, 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair. The site did not performed the testing by October <br /> 13th, 2018. Ensure to conduct overfill prevention equipment inspection within the time frame provided by the <br /> regulation and submit test results within 30 days of performing the inspection. Imminently schedule the overfill <br /> prevention inspection for the 87 product, 91 product and Diesel product system. Ensure a 48 hour notification is <br /> provided to EHD prior to conducting the inspection. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0000306 PR0231485 SCO01 05/29/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 8 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.