UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (page i of 6) <br /> Type ;Ac�fion ❑Installation Test ❑Repair Test ❑Six Month Test m 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID 10180759 Date of Secondary Containment Test <br /> 512912019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Mobil 68222 <br /> Business Site Address City ZIP Code <br /> 2132 Mariposa Rd. Stockton 95205 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Michael McCarter (707)545-5522 <br /> Contractor 1 Tank Tester License 9 ICC Certification# ICC Certification Expiration Date <br /> Able Maintenance, Inc.-312844 8819839 10/25/2019 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID:(By tank number,stored product,etc.) A 87 B 89 C 91 D Diesel <br /> Tank Containment <br /> Tightness Test Result 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result ❑Pass 0 Fall ❑NA 0 Pass ❑Fall ❑NA ❑Pass 0 Fail ❑NA ❑Pass 0 Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail 0 NA ❑Pass ❑Fall 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail [X NA ❑Pass []Fall [INA <br /> Communication Test Result ❑Pass ❑Fait 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail IM NA ❑Pass ❑Fail ®NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA <br /> Communication Test Result ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA <br /> Communication Test Result ❑Pass ❑Fail 0 NA ❑ Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass []Fall 0 NA <br /> Turbine I Product Piping Sump <br /> Tightness Test Result 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA is Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA <br /> VENT I TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑Pass ❑Fail 0 NA ❑Pass [:]Fail 0 NA ❑Pass ❑Fail 0 NA ❑Pass ❑Fail 0 NA <br /> UDC ID: 11/2 2314 3516 4718 <br /> Tightness Test Result ❑Pass 0 Fail ❑NA ❑Pass 0 Fail ❑NA ❑Pass 0 Fail ❑NA ❑Pass 0 Fail ❑NA <br /> UDC ID: 59110 611112 713114 8 <br /> Tightness Test Result ❑Pass 0 Fail ❑NA 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑Pass [:]Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> All items marked"t=ail"or'NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that tine secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3,Chapter 16,Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> -6— <br /> CERS=CaIFbrnlaErr,AronmentW Reporting System,ID=Idertkation,UST=Underground Storage a Tark,ICC=Irrtmnational Code Council,NAW Not Applicable,UDC=Under- <br /> Dispenser <br /> riDispenser Coniahment <br />