COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:45:11 AM
Creation date
9/10/2020 1:39:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
JACKSONS ENERGY #6822
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities <br /> APPENDIX <br /> OPERATIONOVERFILL ALARM <br /> Facility Name: Owner: <br /> Address: Address: <br /> City,State,Zip Code: City,State,Zip Code: <br /> Facility I.D.#: Phone#: <br /> Testing Company: Phone#: Date: <br /> This procedure is to determine whether the high level alarm is operational and will trigger when the tank is no more than 90%full. <br /> See PEI/RP1200 Section 7.3 for the inspection procedure.This procedure is applicable to tank level monitor stems that touch the <br /> bottom of the tank when in place. <br /> Tank Number <br /> Product Stored <br /> Tank Level Monitor Brand and Model <br /> 1.Tank Volume,gallons <br /> 2.Tank Diameter,inches <br /> 3.Overfill alarm activates in the test mode at the p Yes 11No []YesElNo El Yes ElNo El Yes 11No <br /> console? <br /> 4.When activated,overfill alarm can be heard or ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No []Yes ❑No <br /> seen while delivering to the tank? <br /> 5.After removing the probe from the tank,it has <br /> been inspected and any damaged or missing ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> parts replaced? <br /> 6.Float moves freely on the stem without binding? ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes []'No <br /> 7.Moving product level float up the stem trigger <br /> Q Yes ❑No ❑Yes ❑No El Yes 11 No ❑Yes ❑No <br /> alarm? <br /> 8.Inch level from bottom of stem when 90%alarm <br /> is triggered. <br /> 9.Tank volume at inch level in Line 8. <br /> 10.Calculate(Line 9/Line 1)x 100 <br /> 11,Is Line 10 less than 90%? ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> 12.Fuel float level on the console agrees with the ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes No <br /> gauge stick reading? <br /> 13.Overfill alarm activates at any product level ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> above 90%tank capacity? <br /> If any answers in Lines 3,4,5,6,7 or 11 are"No,"or Line 13 is"Yes,"the system has failed the test. <br /> Test Results ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Comments: <br /> Tester's Name(print) Tester's Signature <br /> pei.org <br />