My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:45:11 AM
Creation date
9/10/2020 1:39:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
JACKSONS ENERGY #6822
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEIIRP1200-17 <br /> OPERATIONAPPENDIX C-7 <br /> AUTOMATIC TANK GAUGE <br /> Facility Name: Owner: <br /> Address: Address: <br /> City,State,Zip Code: City,State,Zip Code: <br /> Facility I.D.#: Phone#: <br /> Testing Company: Phone#: Date: <br /> This procedure is to determine whether the automatic tank guage(ATG)is operating properly.See PEVRP1200 Section 8.2 for the <br /> inspection procedure. This procedure is applicable to tank level monitor stems that touch the bottom of the tank when in place. <br /> Tank Number <br /> Product Stored <br /> ATG Brand and Model <br /> I.Tank Volume,gallons <br /> 2.Tank Diameter,inches <br /> 3.After removing the ATG from the tank,it has <br /> been inspected and any damaged or missing ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> parts replaced? <br /> 4.Float moves freely on the stem without ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No []Yes ❑No <br /> binding? <br /> 5.Fuel float level agrees with the value pro- ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> grammed into the console? <br /> 6.Water float level agrees with the value pro- []Yes ❑No []Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> grammed into the console? <br /> 7.Inch level from bottom of stem when 90% <br /> alarm is triggered. <br /> 8.Inch level at which the overfill alarm activates <br /> corresponds with value programmed in the ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> gauge? <br /> 9.Inch level from the bottom when the water <br /> float first triggers an alarm. <br /> 10.Inch level at which the water float alarm acti- <br /> vates corresponds with value programmed in ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> the gauge? <br /> If any answers in Lines 3,4,5,or 6 are`No,"the system has failed the test. <br /> Test Results ❑Pass ❑Fail 1 ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Comments: <br /> Tester's Name(print) Tester's Signature <br /> 0 pei.org <br />