Laserfiche WebLink
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TESORO MOBIL 68222 2132 MARIPOSA RD STOCKTON Aril 18 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The 87 and 91 monitoring plans incorrectly list manufacturer and model information under mechanical leak detector. <br /> -The diesel monitoring plan incorrectly lists the leak detector model as LD2000. The leak detector on site is a 99 <br /> LD-2000. <br /> -The monitoring plans incorrectly state the tank probes are used for inventory only. The probes are currently being <br /> used as part of the overfill prevention methods. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. The missing records include <br /> secondary containment test results for 11/10/16, 4/27/17, and 10/26/17. These records shall be maintained on site for <br /> at least three years. Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring <br /> equipment calibration and maintenance records; (3) results of any visual observations; (4) results of sample analysis <br /> performed a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, ground water <br /> elevations, or other test results; (6) results of inventory readings and reconciliations. Immediately locate and maintain <br /> all maintenance and monitoring records for the last three years on site. <br /> This is a minor violation. <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in the 87 STP sump, the 91 fill sump and the 89 fill sump . If water could enter into the <br /> secondary containment by precipitation or infiltration, it must be removed and disposed of properly. The service <br /> technician removed the liquid from the sumps. Ensure that all sumps and annular spaces are maintained free of <br /> liquid. <br /> This is a minor violation. <br /> FA0001480 PR0231669 SCO01 04/18/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />