EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Z
>
ZUCKERMAN
>
1181
>
2900 - Site Mitigation Program
>
PR0535015
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2020 1:00:47 PM
Creation date
9/11/2020 12:43:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0535015
PE
2960
FACILITY_ID
FA0020252
FACILITY_NAME
PG&E MCDONALD IS COMPRESSOR STATION
STREET_NUMBER
1181
STREET_NAME
ZUCKERMAN
STREET_TYPE
RD
City
TRACY
Zip
95234
APN
12908052
CURRENT_STATUS
01
SITE_LOCATION
1181 ZUCKERMAN RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr.Robert Gray Environmental <br /> 17 June 2014 Resources <br /> Page 5 Management <br /> Fourteen of the 0.5 and 4.5-foot samples were analyzed for metals. The <br /> deeper samples were put on hold, to be analyzed if impacts to the <br /> shallow soil from metals were discovered in the surface samples. Sixteen <br /> of the samples collected were analyzed for ethylene glycol,and the <br /> others were placed on hold. Other than the samples located near the <br /> ethylene glycol storage tanks (SB-13 and SB-19),the sampling locations <br /> and intervals that were chosen for analysis were selected at random,with <br /> a bias towards the shallower 0.5-foot and 4.5-foot sample intervals. <br /> As shown in Table 1, there were no detections of VOCs in any of the <br /> samples and some detections of TPH-diesel and-motor oil in the shallow <br /> 0.5-foot samples at the southern compressor station. Detections of TPH- <br /> diesel ranged from 19 milligrams per kilogram(mg/kg) to 48 mg/kg, <br /> and detections of TPH-motor oil ranged from 160 to 850 mg/kg. All <br /> metals were detected in the shallow soil samples,but only arsenic at <br /> concentrations above Tier 1 Environmental Screening Levels (ESLs). The <br /> Tier 1 ESLs,where applicable,are provided in Table 1 for comparative <br /> purposes. Arsenic was detected in every sample;concentrations ranged <br /> from 1.21 to 8.09 mg/kg. These values fall within the range of <br /> background concentrations of arsenic in Northern California (Diamond <br /> et al,2009). Ethylene glycol was not detected in any of the samples, <br /> including the samples located near the storage tanks at the northern and <br /> southern compressor stations. <br /> QUALITYASSURANCF,/QUALITY CONTROL <br /> All provisions in the Quality Assurance/Quality Control (QA/QC) Plan <br /> were followed during the field work.Specific QA/QC findings include: <br /> • Equipment rinsate samples were collected on both sampling days and <br /> analyzed for CAM 17 metals,TPH,ethylene glycol, and VOCs. <br /> Rinsate samples were collected by running distilled water over the <br /> bucket of the hand auger and capturing the runoff into the sample <br /> containers. Zinc was detected in equipment rinsate sample EB-2; <br /> however,no data were qualified because the detected sample <br /> concentrations were greater than 10 times the blank contamination. <br /> • Trip blanks were placed in the ice chest shipment of samples and <br /> were analyzed for VOCs. No analytes were detected in the trip <br /> blanks. <br />