My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2800 - Aboveground Petroleum Storage Program
>
PR0541436
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2020 6:18:54 PM
Creation date
9/14/2020 4:33:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUINEnvironmental Health Department <br /> - - C. 0UN `l Y - <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> MANTECA CHEVRON 1490 S MAIN ST, MANTECA March 06 , 2019 <br /> File Review <br /> 123 CCR 2637 . 1 (d ) , Failure to submit the "Spill Container Testing Report Form " within 30 days after the test n V n R n COS <br /> 2637. 1 (e) <br /> 124 CCR 2637 . 2(d &e) , "Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of inspection n V n R n COS <br /> 2665( a&b) <br /> On Site Records <br /> 201 CCR 2712 (b) Failure to maintain monitoring , maintenance , and follow up action records ❑ V ❑ R o COS <br /> 202 CCR 2715(c)(3) , Failure to maintain the "Facility Employee Training Certificate" on-site (after October 1 , 2018) ❑ V o R o COS <br /> 2715 (c) (4) <br /> 203 CCR 2712 (b) Failure to maintain records of repairs , lining , and upgrades on site , for the life of the UST n V n R o COS <br /> 204 CCR 2712 (i) Current monitoring plan approved by the EHD not found on site n V n R o COS <br /> 205 CCR 2712 (i) , 2634(e) Failure to submit a current UST Response Plan and have it available onsite o V n R n COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions o V o R o COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment o V o R o COS <br /> 208 CCR 2650(e) , 2652 Failed to notify the EHD of a reportable unauthorized release and/or prepare a report o V o R n COS <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days o V n R n COS <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1 , 2018) o V o R n COS <br /> 211 CCR 2715(c) (2) No employee present that were trained in the operation and maintenance of the UST system by a DO n V o R o COS <br /> 212 CCR 2715(f) (2) Unstaffed facility failed to have or implement a training program approved by the EHD n V o R n COS <br /> 213 HSC 25281 . 5(b) (2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept n V o R n COS <br /> 214 HSC 25281 . 5(b) (3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ❑ V o R o COS <br /> 215 CCR 2712 (i) Failure to retain a copy of the permit to operate at the facility n V n R n COS <br /> UST System Observations <br /> 301 HSC 25292A (a) UST system is not operated to prevent unauthorized release , including spills and overfills ❑ V ❑ R o COS <br /> 302 HSC 25291 (b) UST system incapable of detecting leak from primary into secondary containment (pre-Jul 2003) n V n R n COS <br /> 303 HSC 25290 . 2 (d) Monitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004) n V n R n COS <br /> 304 HSC 25290A (d) Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) ❑ V n R o COS <br /> 305 HSC 25290 . 1 (e) VPH monitoring of the interstitial spaces of the UST system is not maintained o V ❑ R n COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity n V o R n COS <br /> 307 CCR 2631 (g) , 2632 (c) Monitoring system of the interstitial space of a double walled system not maintained ❑ V o R o COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm o V n R n COS <br /> 309 CCR 2636(f) ( 1 ) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product o V n R o COS <br /> 310 CCR 2636 (f) (4) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs n V n R n COS <br /> 311 CCR 2638(a) , 2641 Q) Failed to properly program , calibrate , operate , or maintain leak detection equipment n V n R n COS <br /> 312 CCR 2638 (f) , 2641 ( i) Failed to affix a tag sticker on monitoring equipment certified , repaired , or replaced o V o R n COS <br /> 313 HSC 25290 . 11 25290 . 21 Failure to construct, operate , and maintain primary containment as product-tight ❑ V n R n COS <br /> 25291 <br /> 314 HSC 25290 . 11 25290 . 21 Failed to have secondary containment or secondary containment not tight ❑ V ❑ R o COS <br /> 25291 <br /> FA0023750 PR0541436 SCO02 03/06/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 2 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 952051 T 209 468 - 3420 1 F 209 464 -0138 1 www . sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.