My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2800 - Aboveground Petroleum Storage Program
>
PR0541436
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2020 6:18:54 PM
Creation date
9/14/2020 4:33:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10 A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> MANTECA CHEVRON 1490 S MAIN ST, MANTECA March 06 , 2019 <br /> UST System Observations <br /> 315 HSC 25291 (e) Water in secondary containment not removed , analyzed , and properly disposed of (pre-Jul 2003) ❑ V ❑ R ❑ COS <br /> 316 HSC 25290 . 1 (c3) , Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V ❑ R ❑ COS <br /> 25290 . 2 (c3) <br /> 317 CCR 2636 , 2643(c) ( 1 ) , Line leak detector (LLD) not installed ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 318 CCR 2636(f) (2) Leak detector failed to detect a 3 . 0 gallons per hour leak at 10 pounds per square inch ❑ V ❑ R ❑ COS <br /> 319 CCR 2635 , 2637 . 1 , No spill bucket , failed to contain 5 gallons, no means to keep it empty, or failed to be tested ❑ V ❑ R ❑ COS <br /> 2665 , 2712 <br /> 320 CCR 2635 , 2637 .2 , Failure to comply with the installation , inspection , or record keeping of the overfill prevention ❑ V ❑ R ❑ COS <br /> 2665T2712 <br /> 321 CCR 2635 (b) (2) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 . 6 (a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283 . 5 (a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717 . 1 (g ) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717. 1 (f) Deposited petroleum into a red tagged UST ❑ V ❑ R ❑ COS <br /> 326 HSC 25299(a) (9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 330 CCR 2636(0 , 2666 (c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 331 CCR 2630 (d) , 2641 (a) Liquid does not flow into the sump in the event of a leak (i . e . , failure to remove test boot) . ❑ V ❑ R ❑ COS <br /> 332 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666( b&e) <br /> 333 CCR 2635 , 2636 (b) , Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662 , 2712 <br /> 334 CCR 2666 (b) (2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑ V ❑ R ❑ COS <br /> 335 CCR 2630 , 2632 , 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644 . 1 <br /> Single-Walled Non -Pressurized Piping <br /> 401 CCR 2636(a) (3) , Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643 (d) No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984) . ❑ V ❑ R ❑ COS <br /> 403 CCR 2643 (d) , 2661 (f) Failure to conduct 0 . 1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643 (e) , 2661 (f) Biennial 0 . 1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) 1 ❑ V ❑ R ❑ COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I , CLASS II , or MINOR - Notice to Comply ) <br /> !!!E <br /> Remarks <br /> FA0023750 PR0541436 SCO02 03/06/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 F 209 464 -0138 1 www . sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.