Laserfiche WebLink
2 , auN 'Z` SAN J OAQ U I N Environmental Health Department <br /> COUNTY Kasey Foley, RENS , Interim Director <br /> cgt7Foa?`P Greatness grows here . PROGRAM COORDINATORS <br /> -- Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> November 19 , 2019 <br /> JANELLE DOCKHAM <br /> CONFIDENCE UST SERVICES INC <br /> 16250 MEACHAM RD <br /> BAKERSFIELD , CA 93314 <br /> Re : PERSHING GAS 4 LESS <br /> 4445 N PERSHING AVE SR0080966 <br /> STOCKTON , CA 95207 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of <br /> the application for a permit to do the following on the underground storage tank ( UST) system at <br /> the above noted address . <br /> - Replace 3 dispensers with conversion frames <br /> - Relocate under dispenser containment ( UDC) '/2 . <br /> - install new under dispenser containment ( UDC ) 3/ <br /> - Install additional piping for 87 , 91 and diesel . <br /> - Replace Monitoring Panel . <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Paul Nso at (209 ) 468- 3432 to arrange the following appointments (a 48 - hour <br /> notice is required for inspection appointments ) . <br /> • Verification of the dispenser footprints for all dispensers contained by the under <br /> dispenser containment sumps ( UDCs ) , any potential leaks from piping and fuel filters <br /> drain directly into UDCs . <br /> • Visual inspection of the piping within all the dispensers for any leaks <br /> • Primary piping soap test of all piping . One hour pressure test at the 110 % of operating <br /> pressure or 40psi whichever is greater in accordance with manufacturer installation <br /> instructions . <br /> • Secondary piping soap test of all piping . One hour pressure test at the manufacturer' s <br /> recommended specification . <br /> • Verification of secondary diesel piping slope at 1 /8 inch per foot or greater , to a <br /> containment sump . <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468 -3420 F 209 464 -0138 <br /> www . sjgov , org/ehd <br />