Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> u ;N I YI AMENDED <br /> 10/29/2019 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO CHEROKEE GAS&MART* 900 S CHEROKEE LN, LODI October 24, 2019 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284; CCR 2711(d) Failed to obtain a permit to operate from the EHD including but not limited to unpaid <br /> permit fees. <br /> A permit to operate the UST system has not been issued. No person may own or operate an UST unless a permit <br /> for its operation has been issued by the local agency to the owner or operator of the UST system. Immediately <br /> obtain a permit to operate a UST system from the EHD. An "Operating without a Permit'penalty applies. <br /> This is a Class I violation. <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br /> are required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) <br /> at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a Class II violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms are not current in the California Environmental Reporting System (CERS). <br /> -The tank form for the diesel incorrectly states that the vent lines are double walled. <br /> -The tank forms for all four tanks state that the site is using ball floats for overfill protection.The Overfill Prevention <br /> Equipment Inspection report dated 1/11/19 states no ball floats are present. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> The UST Facility Operating Permit Application contains an incorrect California Department of Tax and Fee <br /> Administration (CDTFA) Underground Storage Tank Account Number.The number is listed as closed with an end <br /> date of 3/14/2019.The application for a permit to operate an underground storage tank shall include the CDTFA <br /> registration number issued to the owner of the tank, in accordance with HSC 25286. Immediately log into the <br /> California Environmental Reporting System (CERS), update the required information, and submit for review by the <br /> EHD. <br /> The UST Facility Operating Permit is not current in CERS. <br /> -The facility form contains information from the previous owner not the current owner/operator. <br /> Any change of information must be updated in the California Environmental Reporting System (CERS)within 30 <br /> days of the changes. Immediately log into CERS, update the required information, and submit for review by the <br /> EHD. <br /> This is a Class II violation. <br /> FA0000556 PR0231841 SCO01 10/24/2019 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />