My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 11:58:54 AM
Creation date
9/15/2020 12:22:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
KPMC MANAGEMENT INC, DBA: ARCO CHEROKEE GAS & MART
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A R N Environmental Health Department <br /> -:a U ;� i _# �V AMENDED <br /> 10/29/2019 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO CHEROKEE GAS&MART* 900 S CHEROKEE LN, LODI October 24, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The diesel monitoring plan incorrectly states that annual pipe line integrity testing is conducted. <br /> -All four monitoring plans left UDC leak sensor manufacturer and model blank. <br /> -On the 87#1 plan tank monitor panel model number and leak sensor manufacturer are switched. <br /> -On the 87#1 and 91 plans the piping panel model and piping leak sensor manufacturer are switched. <br /> -The 87#1 and diesel plans incorrectly list the MLLD model number as LD 99 2000.The model number should be <br /> 99 LD 2000. <br /> -The 91 plan left UDC construction blank <br /> -All four plans list outdated information for person having responsibility. <br /> -The 87#2 leak detector model is is incorrectly listed as a FX1 V.The leak detector on site was a XLP. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 106 CCR 2632(d)(2), 2634(e)Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD. <br /> The response plan contains outdated information in section four. <br /> The response plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, upload the completed form, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 118 CCR 2715(a)(1)(A), 2715(a)(2) Failure to submit the"Underground Storage Tank Statement of Understanding and <br /> Compliance Form". <br /> The Underground Storage Tank Statement of Understanding and Compliance Form for the new owner/operator was <br /> not found in CERS. This form must be uploaded to the California Environmental Reporting System (CERS). <br /> Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov and upload <br /> the Underground Storage Tank Statement of Understanding and Compliance Form for this facility. <br /> This is a Class II violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a Class II violation. <br /> 205 CCR 2712(i), 2634(e)Failure to submit a current UST Response Plan and have it available onsite. <br /> An approved copy of the response plan was not available for inspection. A copy of this plan shall be accessible on <br /> site at all times. Immediately locate and retain a copy on site. <br /> This is a Class II violation. <br /> FA0000556 PR0231841 SCO01 10/24/2019 <br /> EHD 23-01 Rev.9/20/2019 Page 5 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.