My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 1:46:21 PM
Creation date
9/15/2020 1:05:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
AT&T CALIFORNIA - UE058
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB , January 2002 <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br /> Test Method Developed By : ❑ Sump Manufacturer ❑X Industry Standard ❑ Professional Engineer <br /> ❑ Other (Spec) <br /> Test Method Used : ❑ Pressure ❑ Vacuum M Hydrostatic <br /> ❑ Other (Spec) <br /> Test Equipment Used : INCON TS-STS Equipment Resolution : 0 . 0006 <br /> UE0580002 <br /> Sump Diameter: 38" <br /> Sump Depth : 45" <br /> Height from Tank Top to Top of N/A <br /> Highest Piping Penetration : <br /> Height from Tank Top to Lowest 26" <br /> Electrical Penetration : <br /> Condition of sump prior to Good <br /> testing : <br /> Portion of Sump Tested 2" above high pen . <br /> Sump Material : Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and15 minutes <br /> starting test: <br /> Test Start Time : 9: 32am 9: 47am <br /> Initial Reading (RI) : 0. 9509 0. 9523 <br /> Test End Time : 9: 47am 10 : 02am <br /> Final Reading (RF) : 0. 9526 0. 9512 <br /> Test Duration : 15 minute 15 minutes <br /> Change in Reading (RF-Rj) : 0. 0017 10, 0011 <br /> Pass/Fail Threshold or Criteria: . 002 1 , 002 <br /> Test Result : ❑X Pass ❑' Fail ❑ Pass El Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Is there a sensor in the sump? QX Yes [:] No El Yes ❑ No ❑ Yes [:1 No ❑ Yes ❑ No <br /> Does the sensor alarm when ❑ yes [Z] No ❑ NA <br /> either product or water is ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑NA ❑ Yes ❑ No ❑NA <br /> detected? <br /> Was sensor removed for testing? ❑X Yes [:] No ❑ NA ❑ Yes ❑ No ❑NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑No 0 N <br /> Was sensor properly replaced and ❑Yes [E] No [:] NA <br /> verified functional after testing? ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA El Yes ❑ No ❑NA <br /> Comments — (include infor•rnation on repairs made prior to testing, and recommended follow-up fa•failed tests) <br /> The sensor was reinstalled to the lowest point, but not tested . <br />
The URL can be used to link to this page
Your browser does not support the video tag.