My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7272
>
2300 - Underground Storage Tank Program
>
PR0231939
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 3:50:25 PM
Creation date
9/15/2020 3:05:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #3144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l <br /> PEII{2P1200 - 12 <br /> there are items ( hat must be repaired or replaced 6. 5. 6 Test Procedure. <br /> ( e .g . , deteriorated penetration fitting boats ), 1. Be ' it the test by adding water to the sump to a <br /> notify the owner/operator and obtain approval minimum of 4 inches above the highest sump <br /> prior to proceeding with repairs . penetration or sump sidewall seam, whichever is woe <br /> 4. Test boots or secondary containment termtna- higher. To compensate for sump deflection, the <br /> tion fittings must he present on the piping pen- water must be allowed to settle a minimum of <br /> titrating the sump. During testing , these fittings 15 minutes before taking the initial test measure- <br /> prevent water from entering the interstitial spade ment. if the highest sump penetration or sump <br /> of double -walled piping. Without these fittings, sidewall seam is less than 4 inches front the top <br /> the integrity of the sump cannot he tested using of the sump, add water to within I inch of the <br /> this method , top of the sump . <br /> 5. If interstitial monitoring sensors are present 2. Place the measuring stick vertically at the lowest <br /> within the containment sumps, temporarily point in the sump and extending above the: water <br /> remove them before conducting the test . If the level in the sump to allow for an accurate mea- <br /> sensor is removed, reposition after testing to surement to be taken. The lucation of the mea- <br /> appropriate position according to the manufacao curing stick must remain the same for cacti' water <br /> turer ' s instructions . level measurement . Document the initial water <br /> 6. 1f the containment sump is found to have cracks, level measurement as measured from the bottom <br /> Inose phis or separation of any joints or penetr►t - of the sump. Alternative measurement methods <br /> tion fdo ittings , it is not considered to be licluid may be used provided that the measurement to <br /> t / 16 (09063 ) inch can he made <br /> light . 'I7iis visually indicates a test failure, , <br /> 3 . Take all precautions to prevent the water level <br /> CAUTION : Water can damage electrical from being disturbed during the duration of the <br /> connections . Ensure that there are no test, <br /> components that can be damaged by the 4 . After 1 hour, document die ending water level <br /> addition of water to the sump. If such measurement . .w <br /> components are present , take appropriate <br /> precautions when performing the test or S. Upon completion of the test : <br /> use an alternative test method . remove all water and properly dispose of it <br /> according to Section 6. 7 . <br /> reinstall any interstitial monitoring sensors in <br /> their proper positions ; <br /> • return die test boots or secondary contamn <br /> ment fittings to their pre- test operating con- <br /> figurations ; <br /> Wul,ir Elaclrkal <br /> l+�vnl Junction <br /> f Box <br /> Eloctricb! <br /> Gorulul! <br /> wa!e+ <br /> Product L�tel <br /> Piping <br /> �lat�ti�'ul <br /> Cendun <br /> !' educt <br /> FIGURE 6-5, The test fluid level in the UDC musk be at Pping <br /> least 4 inches above the highest sump penetration or <br /> sidewall seam . <br /> - FIGURE 6-6. To prevent leakage, check all penetration ..� <br /> fittings before adding water to ensure they make a tight <br /> seal. <br /> pehorg <br />
The URL can be used to link to this page
Your browser does not support the video tag.