My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 11:05:30 AM
Creation date
9/15/2020 4:54:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #2152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN # 1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S 1 JO <br /> i U I Environmental Health Department <br /> �1 COU 1�1 T <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#2152 1 1721 S CHEROKEE LN, LODI June 13, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 309 CCR 2636(f)(1) Monitoring in sump/ UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Monitoring in the UDC failed to stop the flow of product at the dispenser when tested. <br /> The diesel float and chain in the 3/4 UDC sump failed to trip the shear valve to stop the flow of product at the <br /> dispenser when tested. All monitoring equipment shall be maintained to activate audible and visual alarms or stop the <br /> flow of product at the dispenser when it detects a leak. During inspection the technician attempt to adjust the float <br /> but it did not function properly. The technician determined that it need to be replaced. <br /> Emergency repairs relating to UST system monitoring and release detection may be performed by a properly <br /> licensed, trained, and certified contractor pursuant to the EHD'S policy and a notification shall be submitted or a <br /> permit(if required) shall be obtained within one business day from the EHD. All other repairs must have a permit <br /> submitted to and approved by the EHD prior to beginning work. If the failed component cannot be replaced <br /> immediately, there is a possibility that the diesel UST system may be red tagged. <br /> This is a minor violation. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in the 87 STP fill sump, the 91 fill sump and the diesel fill sump . <br /> If water could enter into the secondary containment by precipitation or infiltration, it must be removed and disposed <br /> of properly. The service technician removed approximately 55gallons of liquid from the diesel fill sump. The 91 fill <br /> sump and 87 fill sump contain approximately 55gallons and 30gallons of liquid respectively pending removal. Ensure <br /> that all sumps and annular spaces are maintained free of liquid. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 13, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152).To schedule an <br /> appointment, please, call (209) 468-3420. <br /> Documents provided: Return to Compliance Cettification form, schedule of free CUPA classes. <br /> FA0000591 PR0232355 SCO01 06/13/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.