My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2200 - Hazardous Waste Program
>
PR0521946
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2024 2:20:06 PM
Creation date
9/16/2020 11:40:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0521946
PE
2247
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 8 of 9 <br />OFFICIAL INSPECTION REPORT <br />Date: 09/21/11 <br />Facility Address: 3250 W Grant Line Rd., Tracy <br />Program: HW <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />Violation 703- An emergency coordinator and modified contingency plan information is lacking 66262.34(d) <br />(2) CCR. <br />There must be at least one emergency coordinator on site or on call to coordinate emergency response measures, and the <br />following information must be posted by a phone: the name and phone number of the emergency coordinator; location of <br />fire extinguishers, spill control equipment, and if present, fire alarm; and the phone number of the fire department, unless <br />the facility has a direct alarm. <br />Immediately appoint an emergency coordinator and post the required information by a phone. A form is <br />provided that can be used for this purpose. Submit proof of correction to the EHD by November 8, 2011. <br />Violation 703 -Employee training 66262.34(d)(2) CCR. <br />At the time of inspection: <br />It could not be demonstrated (not necessarily documented) that employees who handle hazardous waste were properly <br />trained. <br />In the warehouse: Maintenance employees are expected to respond to spills on the floor which could include hazardous <br />waste spills. It was unclear if maintenance workers had been trained to respond to hazardous waste spills and cleanup. It <br />was not demonstrated during the inspection that all employees who were handling, labeling, and storing hazardous waste <br />had a clear understanding of hazardous waste procedures. <br />At the fuel island: According to the signed training titled " Handling Hazardous Waste at Costco Gas Stations in California" <br />and gas station supervisor the last known training was February 2010. The generator must ensure that all employees who <br />handle hazardous waste are thoroughly familiar with proper waste handling and emergency procedures. <br />Immediately provide training to all employees who handle hazardous waste and submit a copy of the training <br />records, including training material to the EHD by November 8, 2011. <br />Violation 804 -UW lamp Storage 66273.33(b) CCR. <br />Violation 808 -UW labeling 66273.34 CCR. <br />Violation 809 -Stored UW onsite for more than 1 year 66273.35 CCR. <br />At time of inspection: <br />42-4 ft bulbs and 4 -8ft bulbs were stored in a box in a maintenance room open, and unlabeled. UW lamps must be stored <br />in a closed container, in a manner to prevent breakage. Universal Waste must be labeled with the words "Universal Waste" <br />and the type of waste, i.e. lamps. It could not be demonstrated how long this UW had been onsite. <br />Immediately have this UW removed and provide this office with a copy of the shipping record/receipt by <br />November 8, 2011. Immediately properly store and label all UW. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received By: <br />Title: <br />Michelle Henry (209) 953-7699 <br />LAsrul� <br />EHD 23-02-003 Rev 07/12/11 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.