My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2500
>
2300 - Underground Storage Tank Program
>
PR0232507
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 10:46:32 AM
Creation date
9/17/2020 1:41:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232507
PE
2361
FACILITY_ID
FA0003846
FACILITY_NAME
Verizon Business: LDIKCA
STREET_NUMBER
2500
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
029-030-39
CURRENT_STATUS
01
SITE_LOCATION
2500 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM ( Page 4 of s) <br /> MIL MONITORING SYSTEM AND PROGRAMMING <br /> This section must be completed if a monitoring panel is used to perform leak detection monitoring. Y N NA <br /> Are the visual and audible alarms operational ? Q✓ ❑ ❑ <br /> Were all sensors visually inspected for kinks and breaks in the cables and for residual buildup to ensure that floats move freely, ❑ ❑ <br /> functionally tested and confirmed operational? <br /> Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with ❑ ❑ ❑✓ <br /> their proper operation? <br /> Was monitoring system set-up reviewed to ensure proper settings? Q ❑ <br /> Was the monitoring panel's backup battery visually inspected , functionally tested , and confirmed operational? ❑ El ❑✓ <br /> Does the flow of fuel stop at the dispenser if a leak is detected In the under-dispenser containment? ❑ ❑✓ ❑ <br /> Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically ❑ F6/ ❑ <br /> disconnected? <br /> Does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak? ❑ 0 ❑ <br /> Which sensors initiate positive shut down? (Check all that apply.) ❑ Sump ❑ Under-Dispenser Containment <br /> If alarms are relayed to a remote monitoring station , is all communications equipment (e. g . , modem ) operational ? ❑ ❑ Q <br /> For any answer of "N" above, describe in Section IX how and when these deficiencies were or will be corrected. <br /> IX. COMMENTS <br /> GENERATOR SYSTEM EXEMPT FROM POSITIVE SHUTDOWN <br /> X. ` INJANK GAUGING TESTING <br /> ❑ Check this box if tank gauging is used only for inventory control . (Do not complete this section.) <br /> ❑✓ Check this box if NO tank gauging equipment is installed. (Do not complete this section.) Y N NA <br /> This section must be con feted if in-tank gauging is used to perform leak detection monitoring. <br /> Has all input wiring been inspected for kinks and breaks in the cables and for proper entry and termination , including testing for ❑ <br /> round faults? <br /> Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally ❑ ❑ ❑ <br /> tested , and confirmed operational? <br /> Was accuracy of system's product level readings tested ? ❑ ❑ ❑ <br /> Was accuracy of system's water level readings tested? ❑ ❑ ❑ <br /> Were all probes reinstalled properly? ❑ I ❑ I ❑ <br /> Were all Items on the equipment manufacturer's maintenance checklist completed? ElElEl <br /> For any answer of "M' above, describe in Section XI how and when these deficiencies were or will be corrected. <br /> i <br /> XI . COMMENTS <br /> Y = Yes, N = No, NA = Not Applicable <br /> iI <br />
The URL can be used to link to this page
Your browser does not support the video tag.