Laserfiche WebLink
UNDERGROUND 'STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM ' Page 5 of 6 <br /> X11. LINELEAK ' DETECTOR TESTING <br /> FCF-1 heck this box if line leak detectors (LLD) are NOT installed . (Do not complete this section.) <br /> Y N NA <br /> This section must be completed if LLDs are installed. <br /> Was a leak simulated to verify LLD performance? © ❑ <br /> (Check all that apply.) Simulated leak rate verified : © 3 GPH E] 0 . 1 GPH E] 0 .2 GPH <br /> Was the testing apparatus properly calibrated ? ❑✓ ❑ ❑ <br /> For emergency generator tank systems , does the LLD create an audible and visual alarm when a leak is detected? ✓❑ ❑ ❑ <br /> For mechanical LLDs , does the LLD restrict the flow through the pipe when a leak is detected? ❑ ❑ ❑✓ <br /> For electronic LLDs , does the turbine automatically shut off when a leak is detected? ❑ ❑✓ ❑ <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system Is disabled or disconnected ? ❑ I ❑✓ ❑ <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? ❑ ✓❑ ❑ <br /> For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? Q ❑ ❑ <br /> Were all items on the equipment manufacturer's maintenance checklist completed? ✓❑ ❑ ❑ <br /> Were all LLDs confirmed operational within regulatory requirements? ❑✓ I ❑ ❑ <br /> For any answer of "N" above, describe in Section Xlll how and when these issues were or will be corrected. <br /> XIII . COMMENTS ' <br /> GENERATOR SYSTEM EXEMPT FROM POSITIVE SHUTDOWN, FINAL INSPECTION AND LEAK TEST PERFORMED <br /> WITH INSPECTOR PRESENT, <br /> XIV. VACUUM / PRESSURE I HYDROSTATIC MONITORING EQUIPMENT TESTING <br /> ❑✓ Check this box if VPH monitoring is NOT used . (Do not complete this section.) <br /> This section must be completed if VPH monitoring is used to perform leak detection monitoring. <br /> System Type (Mark all that apply. ) ❑ Vacuum ❑ Pressure ❑ Hydrostatic <br /> Sensor ID Component(S) Monitored By This Sensor Sensor Functionality Interstitial Communication <br /> Test Test <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br />' ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br />` ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail I ❑ Pass ❑ Fail <br /> How was interstitial communication verified? Simulated Leak at Far Ends of the Interstitial Space ❑ Visual Inspection <br /> ❑ Other (Describe the method in section XV below.) ❑ Gauge <br /> Was the vacuum or pressure restored to operating levels in all interstitial spaces? ❑ Yes ❑ No (Describe the reason in section XV below.) <br /> For any answer of "Fail' above, describe in Section XV how and when these issues were or will be corrected. <br /> XV. COMMENTS <br /> J " <br /> ENVIRONIVIEN Tl <br /> PA i m F, I <br /> f <br /> GPH = Gallons Per Hour, Y = Yes, N = No, NA = Not Applicable, VPH = Vacuum/Pressure/Hydrostatic, ID = Identification <br />