Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> U ; i y I AMENDED <br /> 9/21/2020 <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WESTERN ERECTORS STRUCTURAL STEEL 1 13730 CAMPBELL RD, ESCALON August 18, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 66262.11 Failed to determine if a waste is a hazardous waste. <br /> OBSERVATIONS: The following was located in wash area adjacent to"the barn." <br /> -Operator stated that twice a week equipment that is rented out are washed in the wash area. Equipment <br /> occasionally will have hazardous material on them such as used oil.All rinsate is flows directly to the soil. <br /> REGULATION GUIDANCE: Any person who generates a waste shall determine if the waste is a hazardous waste <br /> as specified in Title 22 California Code of Regulations(CCR). There are wastes that are listed as hazardous <br /> wastes. There are wastes that exhibit one or more of the hazardous waste characteristics:toxic, corrosive, reactive <br /> or ignitable. <br /> CORRECTIVE ACTION: Immediately, stop washing rented equipment in the wash area and make a hazardous <br /> waste determination for each waste, and manage it according to Title 22 CCR. Use Safety Data Sheets(SDS), <br /> waste sampling and test results or other knowledge to make your hazardous waste determination. Waste testing <br /> must be done using methods specified in Title 22 CCR including Title 22 CCR sections 66261.20-24. <br /> Submit a statement and supporting documentation with your hazardous waste determination. Demonstrate current <br /> storage and labeling for wastes determined to be hazardous wastes. Provide disposal records for wastes <br /> determined to be hazardous wastes and stored longer than the number of days specified in Title 22 CCR for your <br /> hazardous waste generator status. <br /> This is a minor violation. <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste. <br /> OBSERVATION: The following was located in"the barn" hazardous waste storage area: <br /> -One 500-gallon diesel tank was observed with leaking diesel onto the soil. Oil pan was placed underneath to <br /> prevent soil impact. <br /> REGULATION GUIDANCE:A hazardous waste generator must maintain and operate its facility to minimize the <br /> possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous <br /> waste constituents to air, soil, or surface water which could threaten human health or the environment. <br /> CORRECTIVE ACTION: Immediately,fix leaking 500-gallon diesel tank. Manage the waste according to Title 22 <br /> California Code of Regulations for hazardous waste. Submit a statement and supporting documentation to the San <br /> Joaquin County Environmental Health Department describing the storage and final disposition of the cleaned up <br /> waste. <br /> This is a minor violation. <br /> FA0026119 PR0546164 SCO01 08/18/2020 <br /> EHD 22-01 Rev.9/16/2020 Page 4 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />