Laserfiche WebLink
WA <br /> ME, <br /> S A N.J O A U I N itjDE Environmental Health Department <br /> Q <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Valle 116 Roth Rd, LathropJune 05, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Fuel filters were observed outside of all under dispenser containments at the auto side of the facility . The <br /> underground storage tank system shall be operated to prevent unauthorized releases. Immediately contact a <br /> properly licensed, trained, and certified contractor to replace or upgrade the component under permit and inspection <br /> (if required) of the EHD. <br /> This is a repeat violation, Class II. <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The S4-91 product auto side sensor failed to have a high liquid alarm when tested. The interstitial space of the UST <br /> shall be maintained, as designed, under constant vacuum such that a breach in the primary or secondary <br /> containment is detected before the hazardous substance is released into the environment. Correct immediately by <br /> having a properly licensed, trained, and certified contractor replace the failed component with a functional component <br /> (LG 113-x listed, if applicable) and obtain a permit within one business day from the EHD. If the failed component <br /> can't be replaced immediately, there is a possibility that the 91 product in the auto side UST system may be red <br /> tagged to prevent fuel inputs. <br /> This is a repeat violation, Class Il. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> Fuel filters were observed outside of all under dispenser containments at the auto side of the facility . The <br /> underground storage tank system shall be operated to prevent unauthorized releases. Immediately contact a <br /> properly licensed, trained, and certified contractor to replace or upgrade the component under permit and inspection <br /> (if required) of the EHD. <br /> This is a repeat violation, Class Il. <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Water was found in the 91 product STP sump, Deisel STP sump, 87 product STP sump, 91 product fill sump, and <br /> vent sump in the auto side. Secondary containment shall be constructed to prevent any water intrusion into the <br /> system by precipitation, infiltration, or surface runoff. Immediately remove this liquid, make a hazardous waste <br /> determination per Title 22 hazardous waste regulations, and manage accordingly. Immediately contact a properly <br /> licensed, trained, and certified contractor to address the water intrusion into the 91 product STP sump, Deisel STP <br /> sump, 87 product STP sump, 91 product fill sump, and vent sump in the auto side under permit and inspection of the <br /> EHD, if required. <br /> This is a repeat violation, Class ll. <br /> FA0015977 PR0523684 SCO01 06/05/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 9 of 10 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />